Experiments › Chemistry
Where does chemical heat come from?
Enthalpy
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can two room-temperature liquids make real heat without fire?
Show the answer
Yes! Chemical reactions can release energy stored inside chemical bonds. Today you will measure that heat jump with a digital sensor.

Introduction
Where Does Chemical Heat Come From?
If you mix two cool liquids together, do you expect them to heat up? Most people think heat only comes from a flame or a stove. But chemicals store energy inside tiny chemical bonds. When those bonds rearrange, that stored energy can turn directly into heat! In this experiment, your teacher will mix three pairs of clear liquids inside an insulated cup. You will watch a digital temperature sensor capture every single degree of chemical heat in real time.
Driving question: Can mixing two cold liquids create real heat?
What you will learn
Today you will discover
- I can explain why mixing two room-temperature chemicals can make water hot.
- I can find the starting temperature and the highest temperature on a live graph.
- I can show how the heat from two reactions adds together to match a third reaction.
- I can explain how an insulated cup traps heat so the sensor can measure it accurately.
- I can follow safety rules around strong acids, bases, and fume hoods.
Why it matters: Emergency hand warmers, self-heating meals, and rocket engines all rely on chemical heat. Controlling reaction energy is essential for modern technology.
Safety first
Safety Rules for Strong Chemicals
- Purple gloves = teacher does it. Blue gloves = you do it.
- 2.0 M hydrochloric acid and 2.0 M sodium hydroxide cause severe chemical burns to skin and eyes.
- Ammonium hydroxide releases strong ammonia fumes. Open the container only inside a fume hood.
- The adult teacher does every chemical transfer in the fume hood.
- Students observe from a safe distance. Wear safety splash goggles at all times.
- Never breathe chemical fumes, touch solutions, or remove glassware from the fume hood.
- Wash your hands fully with soap and water after the demonstration.
What you need
- Go Direct Temperature Probe1 · teacher
- Stir Station1 · teacher
- Electrode Support1 · teacher
- magnetic stir bar1 · teacher
- foam cup2 · teacher
- 400 mL beaker1 · teacher
- 50 mL graduated cylinder2 · teacher
- Tablet running Graphical Analysis1
- 2.0 M acid and base solutions (HCl, NaOH, NH4Cl, NH4OH)50 mL each · teacher
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6 Teacher does this
Assemble the calorimeter on the Stir Station
- The teacher nests a polystyrene foam cup snugly inside a 400 mL beaker.
- Place the beaker onto the circular platform of the Stir Station.
- Attach the Electrode Support arm to the vertical support rod.
- Clamp the Go Direct Temperature Probe so it points straight down into the cup.
- Stir Station is powered off before setup.
- The setup is placed firmly inside the fume hood.
- The foam cup sits flat and does not wobble.
Careful: The cup can tip over if it is not supported by the 400 mL glass beaker. Nest the cup securely in the beaker to keep it steady and add extra insulation.

Step 2 of 6 Teacher does this
Add the first reactant (HCl) and start gentle stirring
- In the fume hood, the teacher measures 50.0 mL of 2.0 M HCl with a graduated cylinder.
- Pour the acid into the foam cup. Add the magnetic stir bar.
- Lower the probe into the liquid. Make sure that it does not strike the stir bar.
- Turn the Stir Station dial to a low, gentle speed.
- Teacher wears purple chemical gloves and splash goggles.
- The fume hood ventilation fan is turned on.
- Students watch from outside the fume hood line.
Careful: 2.0 M HCl can splash and cause painful acid burns, or release vapor that irritates. Work entirely inside the fume hood. Pour slowly down the inner wall of the cup.

Step 3 of 6 Teacher does this
Reaction 1: Combine NaOH and HCl
- The teacher measures 50.0 mL of 2.0 M NaOH in a clean graduated cylinder.
- A student taps Collect on the tablet to record the baseline temperature for 15 seconds.
- The teacher adds all 50.0 mL of NaOH into the cup all at once.
- Watch the graph climb rapidly as neutralization releases chemical heat!
- The tablet is connected and records steady baseline readings.
- The fume hood sash is at the correct safety height.
- Teacher has a secure grip on the cylinder.
Careful: A fast pour can cause splashes. A slow pour allows heat to escape. Pour smoothly all at once. Do not splash. Keep hands clear of the cup rim.

Step 4 of 6 Teacher does this
Record Reaction 1 peak and rinse the cup
- Tap Stop once the temperature peaks and begins to slowly drift downward.
- Tap the peak of the curve to record the maximum temperature in your table.
- The teacher empties the neutralized solution into a lab waste container.
- Rinse the foam cup, stir bar, and probe fully with distilled water. Pat them dry.
- The Stir Station is off before you remove the cup.
- Distilled water wash bottle is ready.
Careful: Leftover liquid will contaminate the next reaction and ruin temperature readings. Rinse the probe tip and cup fully with distilled water. Dry them with clean paper towels.

Step 5 of 6 Teacher does this
Reaction 2: Combine NaOH and NH4Cl
- The teacher measures 50.0 mL of 2.0 M NaOH into the clean foam cup with the stir bar.
- Turn on the stirrer at low speed. Lower the temperature probe into the liquid.
- Measure 50.0 mL of 2.0 M NH4Cl in a second graduated cylinder.
- Tap Collect on the tablet. Wait 15 seconds. Pour the NH4Cl in all at once.
- The fume hood operates normally.
- NH4Cl solution is at room temperature.
- The stir bar rotates smoothly.
Careful: This reaction produces aqueous ammonia, which releases a smell that irritates. Keep the fume hood sash lowered. Do not lean in to smell the cup.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 1: Redox Reactions
- Direct Class 11, Chemistry, chapter 5: Thermodynamics
- Related Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
- Related Level AS & A Level, Chemistry, chapter 13: Nitrogen
- Direct Level AS & A Level, Chemistry, chapter P1: Practical skills 1
- Direct Level AS & A Level, Chemistry, chapter P2: Practical skills 2
- Direct Level DP, Chemistry, chapter Reactivity 1.1: Measuring enthalpy changes
Versions and what each needs
- Where does chemical heat come from?
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.