Experiments › Physics and Environmental Science

Where does our school waste energy?

Project Energy Audit

Grades 7-8Physics and Environmental Science1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

A black power adapter brick glowing faintly red with heat waves while plugged into a wall

Wonder

Why do phone chargers feel warm even when your phone is unplugged?

Show the answer

Chargers continuously pull small amounts of electricity from the wall. They waste it as heat. Today you will track down this phantom power!

A phone charger plugged into an everyday wall outlet with a tiny glowing standby light

Introduction

The Hidden Energy Drain in Your Room

Every day we switch on lights, run computers, and charge phones. But did you know that many plugged-in appliances keep drawing electricity even when turned off? Scientists call this wasted power phantom energy. Today you will inspect real appliances, track their power use, and discover where electrical energy turns into wasted heat.

Driving question: Where does our classroom waste electrical energy, and how can we stop it?

What you will learn

Today you will find out

  • I can calculate power in watts and energy in watt-hours.
  • I can spot phantom loads that waste energy while plugged in.
  • I can use a temperature probe to find warm spots and cold drafts.
  • I can suggest practical ways to cut electrical waste.

Why it matters: Schools and homes spend thousands on wasted electricity. Energy auditors fix these leaks to save money and cut carbon emissions.

Safety first

Scientist Rules for the Energy Audit

  • Never touch mains electrical wall outlets or metal plug pins.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Only your teacher may plug in or unplug equipment from 230 V wall outlets.
  • Keep hands and the metal temperature probe away from electrical outlet holes.
  • Do not pull, pinch, or bend electrical cords when you examine labels.
  • Wash your hands with soap after you handle classroom equipment.

What you need

  • Go Direct Temperature Probe1 per group
  • Tablet running Graphical Analysis1 per group
  • Classroom power adapter or electronic device1 per group
  • ruler1 per group
Notebook showing classroom lighting and device tally marks

Step 1 of 5

Survey your classroom fixtures

  1. Count the total number of light fixtures on the ceiling.
  2. Count how many separate electrical devices connect to power outlets now.
  3. Record these initial numbers in your audit notebook.
Stop and check
  • Keep walkways clear while you look up at ceiling lights.
  • Do not climb on desks or chairs to reach ceiling fixtures.
  • Check whether the windows are single-pane glass or double-pane.

Careful: You trip over student bags while you count ceiling fixtures. Walk carefully along classroom aisles while you observe fixtures.

A student finger pointing to the Output rating on a black adapter label

Step 2 of 5

Read the device rating label

  1. Find the Output line: note the Volts (V) and Amperes (A).
  2. Multiply Volts by Amperes to calculate Power in watts (W = V x A).
  3. If the label directly lists Watts (W), write that number down.
Stop and check
  • The adapter must rest safely on your desk.
  • Do not touch any wall outlet pins.
  • Locate the small printed label on your group's power adapter.

Careful: You misread tiny text on the specification label. Use a good desk light. Examine the Output section carefully.

Teacher inspecting a power cord while student pairs the temperature probe

Step 3 of 5 Teacher does this

Inspect outlets with an adult and power probe

  1. Press the power button to turn on your Go Direct Temperature Probe.
  2. Make sure that the status LED blinks red to prepare for Bluetooth connection.
  3. Open Graphical Analysis on your tablet and pair the probe.
Stop and check
  • The adult confirms power cables are intact.
  • Hands are completely dry.
  • The probe is kept clear of any open wall socket holes.

Careful: The metal probe accidentally touches live electrical outlet terminals. Never insert the metal probe into wall sockets. The teacher supervises all tests near outlets.

Student holding temperature probe handle touching the classroom window glass

Step 4 of 5

Audit room temperatures and drafts

  1. Tap Collect in Graphical Analysis.
  2. Hold the probe tip gently against the window glass pane for 20 seconds.
  3. Tap Keep. Type 'Window'. Repeat this process for 'Door', 'Room Center', and 'Thermostat Wall'.
Stop and check
  • Wait until the digital temperature readout does not move.
  • Hold only the probe handle, not the metal sensor rod.
  • Make sure that the reading stays steady before you tap Keep.

Careful: If you touch the metal rod, body heat warms it and causes false room readings. Grip the white plastic handle only. Allow 20 seconds for thermal balance.

Student holding probe against black laptop adapter brick

Step 5 of 5

Hunt phantom energy heat on power adapters

  1. Hold the flat side of the probe tip against the black plastic power adapter.
  2. Once steady, tap Keep and enter 'Power Adapter'.
  3. Tap Stop to complete your energy audit data collection.
Stop and check
  • The adapter plastic is intact and free of cracks.
  • The probe touches only the outside plastic shell.
  • Watch the temperature reading climb as it absorbs heat from the adapter case.

Careful: You accidentally press the probe against electrical pins. Touch only the solid plastic body of the adapter that rests flat on the table.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 9, Science, chapter 10: Work and Energy

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.