Experiments › Physical Science
Where does the heat go?
Mixing Warm Cold
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
If you mix hot bathwater with cold water, does heat vanish?
Show the answer
Heat never disappears. Warmer water transfers heat to cooler water until both reach the same temperature. Scientists call this thermal energy, and today you will measure it.

Introduction
Where Does the Heat Go?
When you pour cold milk into hot cocoa, the cocoa cools down and the milk warms up. Does the heat energy simply vanish into thin air? Or did the cold milk catch every bit of it? In this experiment, you will build an insulated cup called a calorimeter. You will use two digital temperature probes to track warm and cold water as they mix, and calculate the heat gained and lost.
Driving question: When you mix warm water and cold water, does any heat disappear?
What you will learn
Today you will find out
- I can build and set up a simple cup calorimeter.
- I can measure cold and warm water temperatures at the same time.
- I can calculate heat lost and heat gained in joules.
- I can show that heat lost roughly equals heat gained.
- I can explain where missing heat might escape in real life.
Why it matters: Engineers designing thermos flasks, car engines, and home heating systems must balance heat loss and heat gain every day.
Safety first
Scientist Rules for Today
- Wear safety goggles throughout the experiment to protect your eyes from splashes.
- Make sure the warm water is only warm to the touch (about 30 to 35 °C). Never boil the water.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Carry glassware carefully with two hands. Keep glassware at least 30 cm from electronic tablets.
- Wipe up any spilled water immediately with paper towels to prevent slips.
- Clean and dry the metal probe shafts after use. Wash hands with soap at the end.
What you need
- Go Direct Temperature Probe2
- Tablet running Graphical Analysis1
- 50 mL graduated cylinder1
- 250 mL beaker1
- foam cup1
- ring stand with clamp1
- cold water60 mL (ice-free)
- warm water60 mL (30-35 °C)
- safety goggles1 per student

Step 1 of 6
Build your cup calorimeter
- Place the polystyrene foam cup into the 250 mL beaker for support and extra insulation.
- Position the beaker on the base of your ring stand.
- Attach the utility clamp to the ring stand rod so it hovers directly above the cup.
- Beaker is free of chips or cracks.
- Foam cup fits snugly inside the beaker.
- Ring stand clamp is firmly tightened.
- Put on your safety goggles.
Careful: The ring stand clamp could slip down and knock the beaker. Tighten the clamp thumbscrew firmly by hand before you place glassware.

Step 2 of 6
Connect both Temperature Probes
- Press the power buttons to turn on both Go Direct Temperature Probes.
- Tap Sensor Data Collection. Connect both probes over Bluetooth.
- Label Probe 1 as 'Cold' and Probe 2 as 'Warm' so you can tell them apart.
- Both probe LEDs flash green when turned on.
- Bluetooth is enabled on your tablet or computer.
- Tablet is placed on a dry table surface.
- Open Graphical Analysis on your device.
Careful: If you confuse the probes, you will swap your warm and cold numbers. Put a small piece of tape labelled '1' and '2' on the probe handles.

Step 3 of 6
Measure and pour 50 mL cold water
- Use the 50 mL graduated cylinder to measure exactly 50.0 mL of cold water.
- Pour the cold water into your foam cup calorimeter.
- Clamp Probe 1 so its metal tip sits deep in the cold water. Do not touch the cup bottom.
- Cold water is free of ice chips.
- Graduated cylinder reading is checked at eye level (bottom of meniscus at 50.0 mL).
- Probe 1 tip is fully underwater.
- Make sure NO ice cubes enter the cylinder: water only!
Careful: Ice cubes that melt inside the cup absorb hidden heat energy and ruin your math. Pour liquid cold water only. If an ice cube slips in, fish it out immediately.

Step 4 of 6
Measure 50 mL warm water and insert Probe 2
- Measure exactly 50.0 mL of warm water (around 30 to 35 °C) into the graduated cylinder.
- Place Probe 2 directly into the warm water inside the graduated cylinder.
- Wait at least 45 seconds so both probes adjust to their water temperatures.
- Warm water feels comfortably warm, not hot.
- Graduated cylinder is steady on the bench.
- Probe 2 tip rests submerged in the warm water.
- Rinse the graduated cylinder with warm water.
Careful: The tall graduated cylinder can tip over if bumped with the probe inside. Hold the cylinder steady with one hand while you place Probe 2 inside.

Step 5 of 6
Start collecting and pour the warm water
- Tap Mode to open Data Collection Settings. Set Rate to 1 samples/s and End Collection to 200 seconds. Tap Done.
- Tap Collect in Graphical Analysis to start the measurement.
- Lift Probe 2. Carefully pour ALL 50.0 mL of warm water into the foam cup. Place Probe 2 alongside Probe 1.
- Data collection has started and initial dots show on screen.
- Liquid pours smoothly into the foam cup without a splash.
- Both probe tips are in the cup.
- Watch for the first dots to appear on the graph (about 3 to 5 seconds).
Careful: If you spill water during the pour, the warm water mass changes. This causes wrong heat calculations. Pour smoothly and completely into the cup. Wipe any droplets from the table.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Physics, chapter 3: Thermal Properties of Matter
- Direct Class 11, Physics, chapter 4: Thermodynamics
- Direct Class 7, Physics, chapter 10: Heat Energy and Its General Effects
- Direct Level AS & A Level, Physics, chapter 14: Temperature
- Direct Level DP, Physics, chapter 5: B.1 Thermal energy transfers
Versions and what each needs
- Where does the heat go?
Physical Science, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.