Experiments › Chemistry
Which clear liquid is stronger?
Acid Base Titrations
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can you tell how strong a liquid is when it looks like plain water?
Show the answer
Two clear liquids can look identical, but one can be ten times stronger. Scientists call balancing an acid a titration, and today you will measure it.

Introduction
How Do We Tame a Sour Acid?
Clear acids can look just like plain water, but looks can fool you! Whether inside sour citrus fruit or stomach juices, energetic acid particles are ready to react. To measure their hidden strength, you can add an opposite liquid called a base drop by drop until they cancel each other out. Today, you will track this neutralization reaction to find the exact drop where the acid is balanced.
Driving question: How can tiny drops of a base reveal the hidden strength of an acid?
What you will learn
Today you will find out
- I can explain how a base neutralizes an acid and changes its pH.
- I can spot the steep turning point on a pH graph.
- I can find how much base was needed to balance the acid.
- I can assemble the titration setup and take steady pH readings.
- I can handle lab glassware and chemical solutions safely with an adult.
- I can name real-life uses where neutralization keeps liquids balanced.
Why it matters: Environmental testers check acid rain in lakes, and pharmaceutical labs test medicine purity using titrations. Today you use the exact same technique.
Safety first
Scientist Rules for Today
- Wear chemical splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hydrochloric acid and sodium hydroxide can irritate skin and eyes. Rinse spills immediately with water.
- Never taste or sniff any lab solution.
- Burets have thin glass. Clamp them gently so they do not snap.
- Keep liquids away from tablets and electrical cords.
- Wash your hands fully with soap before you leave the lab.
What you need
- Go Direct pH Sensor1
- Stir Station1
- Electrode Support1
- buret1 (50 mL) · teacher
- ring stand with clamp1 set
- 250 mL beaker2
- magnetic stir bar1
- 0.1 M Hydrochloric acid solution25 mL
- 0.10 M Sodium hydroxide solution60 mL
- Distilled water wash bottle1
- measuring pipet1 (10 mL) with bulb · teacher
- Tablet running Graphical Analysis1

Step 1 of 8 Teacher does this
Adult transfers the acid sample
- Add 50 mL of distilled water to a clean 250 mL beaker.
- The teacher uses a 10 mL pipet and pump to add 10.0 mL of unknown HCl acid.
- Swirl gently to mix. Water gives enough volume for the sensor bulb to stay underwater.
- Everyone wears splash goggles and gloves.
- The beaker sits flat on the table tray.
- Students stand one step back while acid is pipetted.
Careful: Splashes of hydrochloric acid cause painful skin and eye irritation. The adult pipets the acid smoothly with a pipet pump, never by mouth.

Step 2 of 8
Set up the Stir Station
- Place the acid beaker on the center of the Stir Station platform.
- Gently drop in the magnetic stir bar.
- Turn the knob to start a gentle, smooth spin that does not splash.
- Beaker is centred on the round platform.
- Stir speed knob starts at 0 (off).
Careful: A spin that is too fast can throw droplets of acid out of the beaker. Turn the knob slowly to setting 2 or 3 for a gentle vortex.

Step 3 of 8
Position the pH Sensor
- Unscrew the storage bottle and rinse the pH sensor tip with distilled water.
- Slide the sensor into the Electrode Support attached to the Stir Station rod.
- Lower the tip into the liquid so the liquid covers the bulb.
- Storage bottle cap is loosened and slid up the probe.
- The glass bulb is completely underwater.
- There is clear space between the probe tip and the stir bar when it spins.
- Make sure the stir bar does not touch the glass bulb while it spins.
Careful: The stir bar can shatter the delicate glass bulb if it hits while it spins. Keep the probe tip off to one side, well above the bottom of the beaker.

Step 4 of 8 Teacher does this
Fill and clamp the buret
- Fill the buret with ~0.1 M NaOH base solution to near the 0.00 mL mark.
- Drain a few drops into a waste beaker to clear any trapped air bubble.
- Clamp the buret vertically so the tip sits directly over the acid beaker.
- The stopcock is closed before you pour.
- The funnel is off the buret top after you fill the buret.
- Tip of the buret is inside the beaker rim.
- Check that the buret stopcock is closed (horizontal).
Careful: Base solution can overflow the tall buret or splash onto faces and arms. Pour at eye level on the bench. Use a small funnel and never overfill.

Step 5 of 8
Record the starting point (0 mL)
- Tap 'Collect' on the tablet screen.
- Wait for the live pH reading to stabilize around 1.8 to 2.0.
- Tap 'Keep'. Type 0 in the box. Tap 'Keep Point'.
- The stir bar spins smoothly.
- Live pH reading is steady on the screen.
- Read the start level on your buret. If it starts right at 0.00 mL, the volume added is 0 mL.
Careful: If you type the wrong volume, it throws off your whole curve. Look straight at the liquid curve (meniscus) at eye level.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 2: Acids, Bases and Salts
- Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
Versions and what each needs
- Which clear liquid is stronger?
Chemistry through Inquiry, 60 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.