Experiments › Chemistry
Which drinks fight off acid best?
Commercial Products
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does lemonade stay tangy even if you pour in different tap water?
Show the answer
Everyday tap water has different minerals that could spoil a drink's flavour. Drinks use special chemical sponges called buffers that trap acid or base to keep pH steady. Today, you will measure their superpower.

Introduction
The Taste Shield Inside Your Drink
When you buy your favourite sports drink in another city, it tastes exactly the same. But tap water in different places has different minerals and pH! How does the bottle protect its flavour? Inside the liquid is a buffer. A buffer is a chemical team that resists changes in pH when acids or bases are added. Today, you will use a pH sensor and drop counter to watch a buffer hold its ground drop after drop.
Driving question: Why does a sports drink keep its sharp taste even when diluted with tap water?
What you will learn
Today you will find out
- I can explain what a buffer does when acid or base is added.
- I can compare the pH curve of plain acid against a buffered drink.
- I can find the steady buffer zone and the steep turning point on a pH graph.
- I can set up and run a titration using a pH sensor and drop counter.
- I can name where buffers protect living things and foods in real life.
Why it matters: Buffers protect your bloodstream, keep swimming pools balanced, and prevent foods from spoiling quickly.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective lab apron, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sodium hydroxide (0.1 M NaOH) irritates eyes and skin. Rinse immediately with water if you spill it.
- Never taste any lab liquid or commercial drink tested in the science room.
- Burets are tall and made of glass. Handle them gently. Clamp them securely so they do not fall.
- Keep all liquids away from tablet screens and power cables.
- Wash your hands fully with soap and warm water when you finish lab work.
What you need
- Go Direct pH Sensor1 per group
- Go Direct Drop Counter1 per group
- Stir Station and magnetic stir bar1 per group
- 50 mL buret and buret clamp1 per group
- Electrode Support1 per group
- 250 mL beaker2 per group
- 10 mL graduated cylinder1 per group
- 0.10 M Sodium hydroxide solution60 mL per group · teacher
- 0.10 M Citric acid solution25 mL per group
- Commercial buffered drink (decarbonated)50 mL per group
- Distilled water wash bottle1 per group

Step 1 of 7
Assemble the Stir Station and ring stand
- Screw the metal support rod into the base of the Stir Station until it is firmly tight.
- Slide the Go Direct Drop Counter onto the rod so its drop slot points forward.
- Attach the buret clamp above the drop counter on the same rod.
- Tighten the thumbscrews by hand so nothing wobbles.
- The Stir Station is unplugged or switched off while you assemble it.
- The bench surface is completely flat and dry.
- Clamps align directly over the stir plate.
Careful: A loose clamp can slip down the rod and smash glassware below. Double-check that every thumbscrew is firmly hand-tightened.

Step 2 of 7 Teacher does this
Adult fills and positions the buret
- Make sure that the stopcock valve at the bottom of the 50 mL buret is horizontal and closed.
- Place a waste beaker below the buret tip.
- Adult: Use a small funnel. Pour 0.10 M NaOH solution into the top up to about the 0 mL line.
- Open the valve for 2 seconds to fill the tip with liquid and leave zero air bubbles.
- Position the buret so its tip points right through the centre of the Drop Counter slot.
- The adult wears chemical splash goggles and purple gloves.
- Waste beaker is positioned directly under the buret tip.
- The buret stopcock is closed before you pour.
Careful: 0.1 M NaOH can splash into eyes or irritate skin if spilled. Pour at eye level or lower with a funnel. Wipe any drip with a damp cloth immediately.

Step 3 of 7
Prepare the citric acid test beaker
- Measure 10 mL of 0.10 M citric acid solution with the graduated cylinder.
- Pour it into the clean 250 mL beaker.
- Add 50 mL of distilled water so the liquid is deep enough to cover the sensor bulb.
- Carefully drop a white magnetic stir bar into the beaker.
- Center the beaker onto the illuminated Stir Station platform.
- You wear gloves and eye protection.
- Graduated cylinder is read at eye level at the bottom of the liquid curve (meniscus).
- Distilled water is used, not sink tap water.
Careful: If you drop the stir bar heavily, it can crack the bottom of the glass beaker. Tilt the beaker gently and slide the stir bar down the inside wall.

Step 4 of 7
Position and protect the pH sensor
- Unscrew the storage bottle from the Go Direct pH Sensor and rinse the glass bulb with distilled water.
- Slide the pH sensor body into the Electrode Support attached to the Stir Station rod.
- Lower the sensor into the beaker so the acid liquid covers the round bulb.
- Make sure the glass bulb is at the side, completely clear of the stir bar path.
- Turn the Stir Station knob to setting 3 to create a gentle, steady swirl without splashes.
- Sensor glass bulb is kept wet at all times.
- The stir bar does not hit the sensor tip when it rotates.
- Stir speed is gentle, with no vortex splashes.
Careful: If the stir bar strikes the thin glass bulb as it spins, it will shatter the sensor tip instantly. Spin the knob slowly by hand first. Make sure that you have clearance before you turn on power.

Step 5 of 7
Titrate citric acid baseline
- In Graphical Analysis, tap 'Collect' to start data collection.
- Turn the bottom buret stopcock slightly so drops fall at a steady rate of about 1 drop every second.
- Watch the red indicator light on the Drop Counter blink every time a drop falls through the beam.
- Watch the graph grow: notice how the pH crawls slowly along the bottom.
- When around 20 mL of base has entered, watch the graph shoot straight up toward pH 11!
- Once the curve flattens out near pH 12, close the buret stopcock and tap 'Stop'.
- The stirrer spins gently and does not throw drops.
- Drops pass directly through the middle of the Drop Counter slot.
- The drop rate is about 1 drop per second (not a steady stream).
Careful: If you open the valve fully, a liquid stream forms that the drop counter cannot count accurately. Fine-tune the valve until single, separate drops fall calmly.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 6: Equilibrium
- Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
Versions and what each needs
- Which drinks fight off acid best? (burette)
AP Chemistry, 80 min, Based on a Vernier lab
Needs: Go Direct pH Sensor - Which drinks fight off acid best? (drop counter)
AP Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.