Experiments › Chemistry

Which liquid sticks together tighter?

Intermolecular Forces

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two different liquids evaporating at different speeds inside glass dishes

Wonder

Why do some sweet fruit smells escape into the air faster than others?

Show the answer

Liquids are made of molecules that hold hands with different strengths. Today you will race them through a tiny heated obstacle course to see which clings tightest.

An open bottle releasing gentle vapor into the air

Introduction

The Great Molecule Obstacle Course

When you open a bottle of nail polish remover, the smell reaches your nose almost instantly. Other sweet aromas take much longer to drift across the room. Why? Molecules hold onto each other with invisible forces. In this experiment, we turn liquid mixtures into vapor and push them through a narrow coated tube using clean air. Molecules that cling weakly zoom through first. Sticky molecules cling to the tube walls and take longer to escape. Let us see who wins the race!

Driving question: Why do some liquids evaporate and travel faster through a tube than others?

What you will learn

Today you will discover

  • I can explain how a gas chromatograph separates mixed liquids.
  • I can describe what happens to peak arrival times when temperature drops.
  • I can use arrival times on a graph to identify a mystery liquid.
  • I can follow safety rules around hot ports and chemical fumes.
  • I can name real-world careers that use gas chromatography.

Why it matters: Perfume creators, environmental inspectors, and forensic scientists all use gas chromatography to identify mystery chemicals in seconds.

Safety first

Fume Hood and Chemical Safety Rules

  • Wear splash goggles, chemical-resistant gloves, and a fastened lab coat at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The liquids used (acetone, ethyl acetate, 2-butanone) are highly flammable and produce strong vapors.
  • Do all liquid transfers and injections strictly inside an active chemical fume hood.
  • The Mini GC heats the injection port to 110 degrees Celsius. Never touch the brass port.
  • The 1 microliter syringe has an extremely sharp, delicate glass needle. Only the adult injects samples.
  • Keep open flames and heat sources far away from the laboratory area.

What you need

  • Go Direct Mini GC1 instrument · teacher
  • 1.0 microliter glass syringe1 · teacher
  • Tablet or computer with Vernier Instrumental Analysis1
  • Sample vials with septa caps (Solutions 1 to 3, Unknown)4 sealed vials · teacher
  • Acetone cleaning vial1 sealed vial · teacher
  • Lint-free lab wipes1 box · teacher
  • Splash goggles, lab coats, and nitrile gloves1 set per person
Go Direct Mini GC placed inside a stainless steel fume hood

Step 1 of 6 Teacher does this

Set up inside the fume hood

  1. Place the Go Direct Mini GC on the flat work surface inside the chemical fume hood.
  2. Plug the Mini GC power adapter into mains power and turn on the front power switch.
  3. Keep hands behind the sash line while the adult positions the vials.
Stop and check
  • Fume hood airflow monitor shows green and operational.
  • The adult wears purple nitrile gloves, a lab coat, and eye protection.
  • Instrument vents on the side are not blocked.
  • The fume hood exhaust fan runs smoothly.

Careful: If you use organic solvents outside an active hood, dizziness and eye irritation occur. Always keep all vials and the Mini GC at least 15 cm inside the fume hood sash.

Student tapping Apply on the Instrumental Analysis app

Step 2 of 6

Set the temperature profile

  1. Open the Vernier Instrumental Analysis app on your tablet. Connect to the Mini GC.
  2. Set start temperature to 110 degrees Celsius, hold time to 10 minutes, ramp rate to 0 degrees per minute, and pressure to 4.0 kilopascals.
  3. Tap Apply. Wait until the Mini GC LED turns solid green.
Stop and check
  • Tablet is placed outside the hood on the clean bench.
  • Bluetooth or USB connection is established.
  • Start temperature is entered correctly as 110 degrees C.

Careful: An incorrect temperature makes peak arrival times impossible to compare. Double check all values in Table 1 before you tap Apply.

Adult hands holding micro-syringe and checking 0.2 microliter volume against light

Step 3 of 6 Teacher does this

Prepare the micro-syringe

  1. Rinse the 1 microliter syringe three times with pure acetone to clean the needle.
  2. Draw up 0.2 microliters of Solution 1 (acetone and ethyl acetate).
  3. Flick upright to remove air bubbles, then wipe the needle with a lint-free lab wipe.
Stop and check
  • Syringe barrel contains exactly 0.2 microliters of liquid.
  • The plunger moves smoothly and does not bend.
  • Adult wears purple gloves and safety glasses.

Careful: The needle is hair-thin and sharp. If you bend the wire plunger, you ruin the syringe. Handle only by the glass barrel; never force the plunger.

Adult inserting syringe into brass port while student monitors tablet graph

Step 4 of 6 Teacher does this

Inject Solution 1 at 110 degrees C

  1. Guide the needle straight into the top brass port.
  2. Press the plunger down fully in one smooth stroke, then immediately press the physical button on the Mini GC.
  3. Pull the needle straight out instantly and do not tilt it. Watch for two separate peaks on the tablet.
Stop and check
  • LED is solid green on the Mini GC.
  • Student is ready at the tablet to watch the graph start.
  • Needle is positioned straight above the injection port.
  • The Mini GC LED is solid green before you insert the needle.

Careful: The brass port heats to 110 degrees C. If you touch the metal, it causes immediate burns. Only the adult touches the syringe. Students remain at the tablet outside the sash.

Tablet screen showing two overlaid chromatograms where the second peak is delayed

Step 5 of 6 Teacher does this

Lower temperature to 100 degrees C

  1. In the app, adjust the temperature profile to 100 degrees Celsius and tap Apply.
  2. Wait until the Mini GC LED turns solid green before you inject. This shows the sensor cooled to 100 degrees Celsius.
  3. Clean the syringe with acetone. Load 0.2 microliters of Solution 1. Inject the sample. Record the new peak times.
Stop and check
  • Previous run was saved in the app.
  • Mini GC cooled to 100 degrees C and LED turned green.
  • Syringe flushed with pure acetone.
  • The internal fan cools the column until the LED turns solid green again.
  • Notice that the second peak moves further right.

Careful: If you inject before the LED turns green, the baseline curves drift and become messy. Wait patiently for the solid green light before every single injection.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 4: Chemical bonding
IB Diploma
  • Related Level DP, Chemistry, chapter Structure 2.2: The covalent model

Versions and what each needs

  • Which liquid sticks together tighter?
    Organic Chemistry, 60 min, Based on a Vernier lab
    Needs: Go Direct Mini GC

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.