Experiments › Chemistry

Which liquids carry electricity?

Electrolytes

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A tall clear glass of water, a bright blue sports drink bottle, and a salt shaker on a wooden table

Wonder

Can pure water give you an electric shock, or does it need a secret helper?

Show the answer

Pure water hardly carries any electric current at all! It needs dissolved charged particles called ions. Today you find out which liquids carry electricity and why.

A glass of drinking water beside a sports drink and a salt shaker on a sunny kitchen table

Introduction

Which Liquids Carry Electricity?

You have probably heard that water and electricity are a dangerous mix. But here is a surprise: completely pure distilled water does not conduct electricity! What actually carries electric power through water are tiny dissolved charged particles called ions. Today, you will use a digital Conductivity Probe to test salts, acids, and household liquids to discover what turns ordinary water into an electric superhighway.

Driving question: Why do some dissolved substances allow electricity to flow while others block it completely?

What you will learn

Today you will discover

  • I can explain why some liquids conduct electricity and others do not.
  • I can measure electrical conductivity in different liquids.
  • I can group solutions into strong, weak, and non-electrolytes.
  • I can explain why some salts conduct better than others.
  • I can clean and rinse the conductivity sensor between tests.

Why it matters: Electrolytes keep human hearts beating, power modern lithium batteries, and help water treatment plants verify clean drinking water.

Safety first

Scientist Rules for Today

  • Wear chemical splash goggles and protective lab gloves throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The teacher prepares all stock acids and chemical solutions. Do not open stock bottles.
  • Never taste or touch any lab liquid. Do not drink from lab beakers.
  • Rinse the probe with distilled water only over a waste beaker. Never spray toward electronics.
  • If any liquid splashes on skin or eyes, notify your teacher immediately and flush with water for 15 minutes.

What you need

  • Go Direct Conductivity Probe1 per group
  • Stir Station1 per group
  • Electrode Support1 per group
  • Tablet running Graphical Analysis1 per group
  • Distilled water wash bottle1 per group
  • 250 mL beaker1 per group
  • Lint-free tissue box1 box per group
  • Group A solutions (NaCl, CaCl2, AlCl3)3 vials (25 mL each)
  • Group B acid solutions (HCl, H3PO4, HC2H3O2, H3BO3)4 vials (25 mL each)
  • Group C liquids (distilled water, tap water, methanol)3 vials (25 mL each)
  • Splash goggles and nitrile gloves1 set per person
Teacher placing capped chemical vials into a tray in front of students

Step 1 of 7 Teacher does this

Adult prepares and provides solution vials

  1. Your teacher prepares the dilute 0.050 M chemical solutions in advance.
  2. You receive three racks of vials: Group A salts, Group B acids, and Group C liquids.
  3. Place the vials carefully on your tray. Keep caps on all vials until you are ready to test.
Stop and check
  • Everyone wears goggles and gloves.
  • Vials are kept upright in a tray away from table edges.
  • Work surfaces are clean and dry.

Careful: Stock acids and methanol can cause chemical burns, vapour inhalation, or eye damage if mishandled. Only the adult opens concentrated bottles. Students handle pre-diluted, capped vials only.

Student securing the conductivity probe in the electrode support on a Stir Station

Step 2 of 7

Assemble the stand and Conductivity Probe

  1. Attach the Electrode Support clamp to the vertical metal rod of your Stir Station.
  2. Slide the Go Direct Conductivity Probe into the support ring so it hangs straight down.
  3. Make sure the clamp grips the probe body firmly. Keep the tip over the station base.
Stop and check
  • The Stir Station base sits flat on the table.
  • The thumbscrew on the Electrode Support is tightened securely.

Careful: A loose clamp can let the probe slide down and strike the table or crack a vial. Tighten the clamp thumbscrew firmly with your fingers before you attach the probe.

Conductivity probe glowing green connected to tablet showing Graphical Analysis

Step 3 of 7

Connect the probe to Graphical Analysis

  1. Press the power button on your Go Direct Conductivity Probe.
  2. Open Vernier Graphical Analysis on your tablet or computer.
  3. Tap Sensor Data Collection. Find your probe name. Connect with Bluetooth.
Stop and check
  • Hands and gloves are dry before you touch the tablet.
  • The tablet is placed at least 30 cm away from open water beakers.
  • If your probe has a physical range switch, make sure it is set to 0–20000 µS/cm.

Careful: Liquid on the tablet or probe charging port can short-circuit electronics. Keep liquids on the tray and tablet on the dry side of the bench.

Student raising a glass vial around the probe tip so the side hole is fully under liquid

Step 4 of 7

Test Group A salt solutions

  1. Uncap the 0.05 M NaCl vial. Raise the vial until the liquid covers the probe hole completely.
  2. Swirl the vial gently around the probe for 6 to 8 seconds and record the stable reading.
  3. Lower the vial, rinse the probe, and repeat for 0.05 M CaCl2 and 0.05 M AlCl3.
Stop and check
  • The hole on the side of the probe tip is fully submerged.
  • The probe tip does not touch the bottom of the glass vial.

Careful: If the liquid covers only half of the side hole, the graphite electrodes cannot complete the circuit. This gives a false reading. Lift the vial high enough so the liquid level is well above the side hole.

Rinsing the probe tip with distilled water from a wash bottle over a waste beaker

Step 5 of 7

Rinse and blot the probe between tests

  1. Place or hold a 250 mL waste beaker directly underneath the probe tip.
  2. Squeeze your wash bottle to spray distilled water fully over the probe tip and through the hole.
  3. Blot the outside of the probe dry with a clean tissue.
Stop and check
  • The wash bottle has pure distilled water, not tap water.
  • The waste beaker catches all runoff drips.
  • Do NOT force tissue inside the tiny hole. A drop of distilled water inside is completely fine.

Careful: Leftover drops from a strong salt solution will contaminate weak solutions and ruin your data. Rinse fully with distilled water before every single new solution test.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 7, Science, chapter 2: Exploring Substances: Acidic, Basic, and Neutral
  • Direct Class 10, Science, chapter 2: Acids, Bases and Salts
  • Related Class 10, Science, chapter 3: Metals and Non-metals
  • Related Class 10, Science, chapter 4: Carbon and its Compounds
  • Direct Class 11, Chemistry, chapter 4: Chemical Bonding and Molecular Structure
  • Direct Class 11, Chemistry, chapter 6: Equilibrium
  • Related Class 12, Chemistry, chapter 1: Solutions
  • Related Class 12, Chemistry, chapter 2: Electrochemistry
  • Related Class 12, Chemistry, chapter 5: Coordination Compounds
ICSE (CISCE)
  • Direct Class 8, Chemistry, chapter 6: Chemical Bond Valency and Radioactivity
  • Related Class 8, Chemistry, chapter 9: Methods for the Preparation of Hydrogen
  • Direct Class 9, Chemistry, chapter 4: Atomic Structure and Chemical Bonding
  • Direct Class 10, Chemistry, chapter 3: Acids Bases and Salts
  • Direct Class 10, Chemistry, chapter 6: Electrolysis
  • Related Class 10, Chemistry, chapter 9: Ammonia and Nitric Acid
Cambridge AS & A Level
  • Direct Level AS & A Level, Biology, chapter 2: Biological molecules
  • Related Level AS & A Level, Chemistry, chapter 4: Chemical bonding
IB Diploma
  • Direct Level DP, Chemistry, chapter Structure 2.1: The ionic model

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.