Experiments › Chemistry
Which metal makes the strongest battery?
Micro Voltaic Cells
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a piece of paper and two tiny metal squares power a clock?
Show the answer
Every pair of metals has a different tug-of-war for electrons. When you connect them with wet salt paper, electrons rush across and make an electric push. Today you will build five tiny batteries on a single sheet of paper!

Introduction
Which Metal Makes the Strongest Battery?
Every battery in your remote control or flashlight works using chemical energy. Inside, two different metals compete for tiny electric particles called electrons. One metal pushes electrons away easily, while the other pulls them in tightly. In this experiment, you will build five miniature battery cells on a piece of paper. By measuring their electric push with a voltage probe, you will discover which metals are the strongest pushers and which are the strongest pullers.
Driving question: Can two drops of liquid and two pieces of metal create real electricity?
What you will learn
Today you will discover
- I can explain how two different metals make a tiny battery cell.
- I can measure the voltage between different metal pairs.
- I can rank metals from lowest to highest electric push.
- I can predict the voltage between other metal pairs and test my prediction.
- I can build paper battery cells safely without touching chemical liquids.
Why it matters: Electric cars, smartphones, and pacemakers all depend on choosing the right metals to generate electrical voltage.
Safety first
Scientist Rules for Today
- Wear safety goggles, nitrile gloves, and a lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The adult dispenses all chemical liquid drops. Some solutions contain lead or silver, which can poison or cause skin stains.
- Keep the top face of each metal square completely dry so liquid does not touch your probe clips.
- Use forceps to place or move metal squares; never pick them up with bare fingers.
- Wash your hands fully with soap and warm water when you finish the experiment.
What you need
- Go Direct Voltage Probe1
- Tablet running Graphical Analysis1
- glass plate, 15 x 15 cm1
- filter paper, 11.0 cm diameter1 sheet
- 1 cm x 1 cm metals M1, M2, M3, M4, and M55 pieces (Cu, Zn, Pb, Ag, Fe)
- sand paper1 small sheet
- forceps1 pair
- 1 M solutions of M1 2+, M2 2+, ..., and M5 2+5 dropper bottles (dispensed by adult) · teacher
- 1 M NaNO31 dropper bottle (dispensed by adult) · teacher
- goggles1 pair per person

Step 1 of 7
Prepare the filter paper wheel
- Place the glass plate flat on your lab table.
- Take the circular filter paper disc. With a pencil, draw five circles around the edge and label them M1, M2, M3, M4, and M5.
- Draw pencil lines that connect each circle to the centre.
- Use scissors to cut small wedges between the circles so they form 5 separate petals connected at the centre.
- Lay the cut filter paper flat on top of the glass plate.
- The glass plate rests flat and steady on the table.
- Pencil marks the labels, not ink pens (ink bleeds when wet).
- Cut carefully only into the gaps with scissors. Keep the centre intact.
Careful: Ink from ink pens dissolves in water and contaminates the solutions. Glass edges can chip if knocked. Use a standard graphite pencil. Keep the glass plate centred on your work mat.

Step 2 of 7
Sand the 5 metal pieces shiny
- Take each metal square (M1 through M5) one by one.
- Rub both sides of each metal square with sandpaper until the dark layer comes off and the metal is shiny.
- Wipe off any metal dust with a dry paper towel.
- Place each shiny metal piece on the table right next to the circle with the same number.
- Wear your safety goggles and blue gloves.
- Sand gently on a paper towel to catch metal dust.
Careful: Metal dust can irritate eyes if touched. Dull oxide coatings on un-sanded metal block voltage readings. Sand both sides until bright metal gleams. Keep your gloved hands away from your eyes.

Step 3 of 7
Connect and zero the Voltage Probe
- Switch on your Go Direct Voltage Probe and pair it with Graphical Analysis on your tablet.
- Clip the red (+) alligator clip directly to the black (-) alligator clip so their metal jaws touch.
- On the tablet screen, tap the Potential meter readout and select 'Zero'.
- Unclip the two leads. The screen should now read 0.00 V.
- Probe leads are clean and completely dry.
- Tablet is securely propped up away from liquids.
Careful: An un-zeroed probe displays a small false voltage offset. This error changes every reading. Make sure that the metal teeth of the alligator clips touch firmly while you tap Zero.

Step 4 of 7 Teacher does this
Adult dispenses chemical drops and salt bridge
- The teacher adds 3 drops of the correct solution onto each numbered circle (for example, M1 solution onto circle M1).
- Use forceps to set each shiny metal piece carefully on top of its wet spot.
- CRITICAL: Keep the top surface of each metal piece completely dry!
- The teacher adds several drops of 1 M NaNO3 along each pencil line. This makes a wet bridge to the centre.
- The adult wears purple gloves and eye protection.
- Students wear blue gloves and use forceps to touch metals.
- Solutions are labelled clearly M1 through M5 and NaNO3.
Careful: Lead nitrate (M3) is toxic and silver nitrate (M4) causes dark skin stains. Liquid on top of metal corrodes probe clips. The adult dispenses all drops. Students use forceps to place metal squares carefully so drops do not splash.

Step 5 of 7
Measure reference cells with copper (M1)
- Metal M1 (copper) is your reference standard.
- Touch the red (+) lead to the dry top of M1 and the black (-) lead to M2.
- If the voltage is positive, wait 5 seconds and record the value (round to 0.01 V).
- If the voltage is negative, swap the leads so the reading becomes positive! Record the positive number and note which metal has the (+) lead.
- Repeat this measurement for M1 with M3, M1 with M4, and M1 with M5.
- Touch only the dry top surface of each metal.
- Do not let the alligator clips dip into the wet solution on the paper.
- If the paper looks dry, ask your teacher to add 1 drop of NaNO3.
Careful: Dipping clips into chemical liquid ruins probe contacts and causes erratic drifting voltages. Press gently straight down onto the dry metal face. Never drag clips across the paper.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 3: Metals and Non-metals
- Related Class 11, Chemistry, chapter 1: Redox Reactions
Versions and what each needs
- Which metal makes the strongest battery?
Chemistry with Vernier, 60 min, Based on a Vernier lab
Needs: Go Direct Voltage Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.