Experiments › Biology
Which olive oil is real?
Olive oil spectrum
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a beam of light reveal what is really inside your cooking oil?
Show the answer
Pure extra virgin olive oil carries green chlorophyll straight from fresh olives. Today, you will shine a rainbow through different oils to unmask an unknown bottle.

Introduction
The Olive Oil Mystery
Extra virgin olive oil is pressed directly from fresh olives. It has a rich green-gold tint and a fresh scent. Cheaper oils are heated, filtered, and pressed again, stripping away natural plant nutrients. Some dishonourable sellers even mix cheap oils and sell them at luxury prices! How can food detectives tell which oil is truly top quality? By reading its light fingerprint! In this lab, you will measure the rainbow spectrum of three known olive oils and test an unknown sample to uncover its true grade.
Driving question: Can we use a rainbow of light to uncover the hidden grade of olive oil?
What you will learn
Today you will find out
- I can explain which colours of light chlorophyll absorbs.
- I can compare the light spectra of different olive oil grades.
- I can identify an unknown olive oil using its light spectrum.
- I can fill, cap, and load cuvettes without smudging the clear sides.
- I can describe how food scientists detect fake or low-grade oils.
Why it matters: Food safety scientists, customs agents, and botanists use light spectrometers to authenticate foods, verify medicines, and measure plant health from space.
Safety first
Scientist Rules for Today
- Wear safety goggles, lab aprons, and nitrile gloves at all times.
- Never taste or drink any oil sample. Never use lab equipment for food.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Wipe up any oil drips immediately. Oil makes tables and floors dangerously slippery.
- Handle isopropyl alcohol with care: keep it away from open flames and keep bottles capped.
- Always cap your cuvettes before you place them inside the spectrophotometer.
- Keep all liquids at least 30 cm away from tablets and the spectrometer's USB port.
What you need
- Go Direct SpectroVis Plus Spectrophotometer1 per group
- Plastic cuvette (4 clear sides)5 with snap lids
- Tablet running Graphical Analysis1 per group
- Plastic Beral pipets4
- vegetable oil in bottle10 mL each (Light, Regular, Extra Virgin)
- yellow or orange liquid in a reagent bottle10 mL labelled Unknown
- Distilled water wash bottle20 mL
- clear liquid in a wash bottle30 mL isopropyl alcohol
- Cuvette Rack1
- Lint-free tissue box1 box (Kimwipes)
- Splash goggles and nitrile gloves1 set per student

Step 1 of 8
Label your five cuvette lids
- Take five clean cuvette caps.
- Use a permanent marker to label the tops of the caps. Write W (water), L (light), R (regular), EV (extra virgin), and U (unknown).
- Place the five empty cuvettes upright in your cuvette rack.
- All five cuvettes are completely dry and clean.
- The cuvette rack rests flat on your lab table.
Careful: Ink on the clear sides of the cuvette will absorb light and produce false readings. Write only on the small white cap, never on the clear walls of the cuvette.

Step 2 of 8
Fill cuvettes with standards and unknown
- Fill cuvette W three quarters full with distilled water.
- Fill cuvettes L, R, EV, and U three quarters full with the correct oils.
- Press each labelled cap on firmly until it snaps tight.
- You have four separate plastic pipets ready for the oils.
- Paper towels are placed beneath the cuvette rack to catch any drips.
- Use a dedicated pipet for each liquid so the samples do not mix.
Careful: If you fill the cuvette too full, oil spills into the sensor. If you fill it too low, light does not pass through the oil. Fill exactly three quarters full (about 3 mL) and press caps on tightly.

Step 3 of 8
Power and connect the spectrometer
- Press the power button on your Go Direct SpectroVis Plus.
- Connect to your spectrometer with Bluetooth or a USB cable.
- Select 'Absorbance vs. Wavelength (Full Spectrum)' as the experiment mode.
- The spectrometer rests on a completely dry area of the lab bench.
- The tablet is at least 30 cm away from all open oil containers.
- The Vernier Spectral Analysis app is open on your tablet.
Careful: If you select the wrong collection mode, the software records single wavelengths instead of a full visible rainbow curve. Make sure you choose 'Absorbance vs. Wavelength (Full Spectrum)'.

Step 4 of 8
Calibrate with distilled water
- Insert cuvette W into the sample slot of the spectrometer.
- In Spectral Analysis, tap Calibrate.
- Tap 'Finish Calibration' after the 90 seconds lamp warmup timer finishes.
- Cuvette W has only distilled water inside.
- The clear optical faces have been wiped completely free of smudges.
- A lint-free tissue wiped the clear sides of cuvette W (distilled water).
Careful: Fingerprints or lint on the cuvette absorb light and make all later measurements inaccurate. Hold the cuvette only by its frosted edges or cap. Wipe clear faces with Kimwipes.

Step 5 of 8
Scan the Light Olive Oil standard
- Remove cuvette W. Insert cuvette L into the spectrometer slot.
- Tap 'Collect'.
- Tap 'Stop' once the spectrum line stabilizes. Tap the File Cabinet icon to store this run.
- Cuvette L cap is pressed tightly so oil cannot spill.
- Clear faces of the cuvette are clean and smudge-free.
- Cuvette W is removed and placed back into your rack.
- The sides of cuvette L (Light Olive Oil) are wiped with a lint-free wipe.
- Cuvette L is inserted into the spectrometer slot.
Careful: If you do not store the run, the software overwrites your data when you scan the next oil. Always tap the File Cabinet icon or 'Keep Run' after data collection stops.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Biology, chapter 11: Photosynthesis in Higher Plants
- Related Level AS & A Level, Biology, chapter 13: Photosynthesis
- Related Level DP, Biology, chapter C1.3: Photosynthesis
Versions and what each needs
- Which olive oil is real?
Advanced Biology, 60 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.