Which olive oil is real?

Olive oil spectrum

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glass bottle of golden green olive oil with olives and a warm sunlight beam passing through

Wonder

Can a beam of light reveal what is really inside your cooking oil?

Show the answer

Pure extra virgin olive oil carries green chlorophyll straight from fresh olives. Today, you will shine a rainbow through different oils to unmask an unknown bottle.

Three small glass tasting bowls containing different shades of olive oil side by side

Introduction

The Olive Oil Mystery

Extra virgin olive oil is pressed directly from fresh olives. It has a rich green-gold tint and a fresh scent. Cheaper oils are heated, filtered, and pressed again, stripping away natural plant nutrients. Some dishonourable sellers even mix cheap oils and sell them at luxury prices! How can food detectives tell which oil is truly top quality? By reading its light fingerprint! In this lab, you will measure the rainbow spectrum of three known olive oils and test an unknown sample to uncover its true grade.

Driving question: Can we use a rainbow of light to uncover the hidden grade of olive oil?

What you will learn

Today you will find out

  • I can explain which colours of light chlorophyll absorbs.
  • I can compare the light spectra of different olive oil grades.
  • I can identify an unknown olive oil using its light spectrum.
  • I can fill, cap, and load cuvettes without smudging the clear sides.
  • I can describe how food scientists detect fake or low-grade oils.

Why it matters: Food safety scientists, customs agents, and botanists use light spectrometers to authenticate foods, verify medicines, and measure plant health from space.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Never taste or drink any oil sample. Never use lab equipment for food.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Wipe up any oil drips immediately. Oil makes tables and floors dangerously slippery.
  • Handle isopropyl alcohol with care: keep it away from open flames and keep bottles capped.
  • Always cap your cuvettes before you place them inside the spectrophotometer.
  • Keep all liquids at least 30 cm away from tablets and the spectrometer's USB port.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per group
  • Plastic cuvette (4 clear sides)5 with snap lids
  • Tablet running Graphical Analysis1 per group
  • Plastic Beral pipets4
  • vegetable oil in bottle10 mL each (Light, Regular, Extra Virgin)
  • yellow or orange liquid in a reagent bottle10 mL labelled Unknown
  • Distilled water wash bottle20 mL
  • clear liquid in a wash bottle30 mL isopropyl alcohol
  • Cuvette Rack1
  • Lint-free tissue box1 box (Kimwipes)
  • Splash goggles and nitrile gloves1 set per student
Student writing letters on cuvette lids with a permanent marker

Step 1 of 8

Label your five cuvette lids

  1. Take five clean cuvette caps.
  2. Use a permanent marker to label the tops of the caps. Write W (water), L (light), R (regular), EV (extra virgin), and U (unknown).
  3. Place the five empty cuvettes upright in your cuvette rack.
Stop and check
  • All five cuvettes are completely dry and clean.
  • The cuvette rack rests flat on your lab table.

Careful: Ink on the clear sides of the cuvette will absorb light and produce false readings. Write only on the small white cap, never on the clear walls of the cuvette.

Student pipetting golden olive oil into a clear cuvette resting in a rack

Step 2 of 8

Fill cuvettes with standards and unknown

  1. Fill cuvette W three quarters full with distilled water.
  2. Fill cuvettes L, R, EV, and U three quarters full with the correct oils.
  3. Press each labelled cap on firmly until it snaps tight.
Stop and check
  • You have four separate plastic pipets ready for the oils.
  • Paper towels are placed beneath the cuvette rack to catch any drips.
  • Use a dedicated pipet for each liquid so the samples do not mix.

Careful: If you fill the cuvette too full, oil spills into the sensor. If you fill it too low, light does not pass through the oil. Fill exactly three quarters full (about 3 mL) and press caps on tightly.

Spectrometer showing a glowing green LED next to a tablet running Spectral Analysis

Step 3 of 8

Power and connect the spectrometer

  1. Press the power button on your Go Direct SpectroVis Plus.
  2. Connect to your spectrometer with Bluetooth or a USB cable.
  3. Select 'Absorbance vs. Wavelength (Full Spectrum)' as the experiment mode.
Stop and check
  • The spectrometer rests on a completely dry area of the lab bench.
  • The tablet is at least 30 cm away from all open oil containers.
  • The Vernier Spectral Analysis app is open on your tablet.

Careful: If you select the wrong collection mode, the software records single wavelengths instead of a full visible rainbow curve. Make sure you choose 'Absorbance vs. Wavelength (Full Spectrum)'.

Student placing cuvette of water into the spectrometer well while the tablet calibrates

Step 4 of 8

Calibrate with distilled water

  1. Insert cuvette W into the sample slot of the spectrometer.
  2. In Spectral Analysis, tap Calibrate.
  3. Tap 'Finish Calibration' after the 90 seconds lamp warmup timer finishes.
Stop and check
  • Cuvette W has only distilled water inside.
  • The clear optical faces have been wiped completely free of smudges.
  • A lint-free tissue wiped the clear sides of cuvette W (distilled water).

Careful: Fingerprints or lint on the cuvette absorb light and make all later measurements inaccurate. Hold the cuvette only by its frosted edges or cap. Wipe clear faces with Kimwipes.

Student placing cuvette L into the spectrometer while the graph displays a low flat curve

Step 5 of 8

Scan the Light Olive Oil standard

  1. Remove cuvette W. Insert cuvette L into the spectrometer slot.
  2. Tap 'Collect'.
  3. Tap 'Stop' once the spectrum line stabilizes. Tap the File Cabinet icon to store this run.
Stop and check
  • Cuvette L cap is pressed tightly so oil cannot spill.
  • Clear faces of the cuvette are clean and smudge-free.
  • Cuvette W is removed and placed back into your rack.
  • The sides of cuvette L (Light Olive Oil) are wiped with a lint-free wipe.
  • Cuvette L is inserted into the spectrometer slot.

Careful: If you do not store the run, the software overwrites your data when you scan the next oil. Always tap the File Cabinet icon or 'Keep Run' after data collection stops.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 11: Photosynthesis in Higher Plants
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 13: Photosynthesis
IB Diploma
  • Related Level DP, Biology, chapter C1.3: Photosynthesis

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.