Experiments › Earth Science and Physics

Which way does a magnet push?

Exploring Magnetism

Grades 7-8Earth Science and Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Iron filings forming curved arching lines around a bar magnet on a clean card

Wonder

Can you feel a force pushing when nothing is touching?

Show the answer

Magnets create an invisible field of force in the space around them. Today you will map this invisible field with a 3-axis sensor and discover which way it flows.

Two hands holding magnets close together feeling repulsive force

Introduction

The Invisible Web of Magnetism

Hold two strong magnets close together. Before they even touch, your hands feel a mystery push or pull. What travels through that empty gap? An invisible region of force called a magnetic field! In this lab, you will use a digital 3-axis magnetic sensor to reveal that invisible web. You will find which end pushes and which pulls, and trace how the field loops through 360 degrees.

Driving question: How can we map the invisible shape and direction of a magnetic field?

What you will learn

Today you will find out

  • I can explain how the two ends of a magnet create opposite field directions.
  • I can describe how distance changes the strength of a magnetic field.
  • I can map how sensor direction affects magnetic readings around a full circle.
  • I can zero and align the magnetic sensor on a lab table.
  • I can explain how Earth acts like a giant magnet that guides compasses and protects life.

Why it matters: Magnetic fields protect Earth from deadly solar radiation, steer ships across oceans, and store data in computer hard drives.

Safety first

Scientist Rules for Today

  • Keep strong magnets at least 30 cm away from tablets, phones, and credit cards.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never drop or slam bar magnets together. Hard impacts can weaken or reverse their magnetism.
  • Use blunt-end scissors carefully when you cut the paper degree wheel and pointer.
  • Clear all steel objects, paper clips, and iron table legs away from your measurement zone.
  • Wash your hands after you use lab equipment.

What you need

  • Go Direct 3-Axis Magnetic Field Sensor1
  • Unmarked bar magnet1
  • Degree wheel and pointer card1 printed sheet
  • Tablet running Graphical Analysis1
  • Roll of tape1 roll
  • Scissors1 pair
  • Paper clips5
  • Small stickers or marker tags1 sheet
Sensor taped flat on wooden table with +Z facing up

Step 1 of 8

Connect and tape the sensor

  1. Open Graphical Analysis on your tablet or computer.
  2. Turn on the Go Direct 3-Axis Magnetic Field Sensor. Connect it with Bluetooth.
  3. Tape the sensor firmly flat to your wooden desk. Make sure that the +Z label points straight up so it cannot slide.
Stop and check
  • Table is wooden, not metal.
  • All magnets are at least 1 metre away from the sensor for now.
  • Tape holds the wand firmly flat.

Careful: Accidental sensor movement during data collection produces false peaks. Tape the sensor wand flat across the desk with blue painter tape.

Student tapping Zero on the Graphical Analysis meter

Step 2 of 8

Zero the sensor

  1. Move all bar magnets and iron objects at least 1 metre away from the sensor.
  2. In Graphical Analysis, tap the Magnetic Field meter readout and choose Zero.
  3. Confirm the reading now sits very close to 0.00 mT.
Stop and check
  • No magnets are near the sensor.
  • Keys, phones, and steel watches are kept away.
  • The sensor wand is completely still.

Careful: If you zero the sensor near a magnet, you remove the magnet signal and ruin all future readings. Keep all magnets across the room while you zero the sensor.

Bar magnet placed 20 cm away from the tip of the sensor wand

Step 3 of 8

Align the magnet 20 cm away

  1. Place the unmarked bar magnet flat on the table, lined up directly with the sensor wand.
  2. Position one end of the magnet exactly 20 cm away from the sensor tip.
  3. Notice which end of the magnet points at the sensor.
Stop and check
  • The magnet rests flat on the table.
  • Magnet is in line with the long axis of the sensor wand.

Careful: If you tilt the magnet, you change the angle of field lines that enter the sensor. Keep the magnet flat on the tabletop when you slide it.

Student sliding bar magnet toward sensor wand while graph records a peak

Step 4 of 8

Test Trial 1: Move magnet toward sensor

  1. Tap Collect in Graphical Analysis.
  2. Slowly slide the magnet straight toward the sensor tip. Stop 1 cm away. Slide it back to 20 cm over 10 seconds.
  3. Observe whether the peak goes UP (positive) or DOWN (negative).
Stop and check
  • Magnet stays flat on the table.
  • Do not hit or ram the plastic tip of the sensor wand.

Careful: If you hit the sensor tip, you can crack the plastic wand or loosen the tape. Stop the magnet smoothly about 1 to 2 cm before it touches the sensor tip.

Student sticking a small red dot sticker on the positive end of the bar magnet

Step 5 of 8

Test Trial 2: Flip the magnet around

  1. Turn the bar magnet around so the opposite end faces the sensor tip, lined up 20 cm away.
  2. Tap Collect. Repeat the same 10-second slide toward the tip and back.
  3. Place a small sticker on the end of the magnet that gave a POSITIVE reading.
Stop and check
  • Magnet has been rotated 180 degrees.
  • Have a small sticker ready to label the positive pole.

Careful: If you forget which end you tested, you cannot identify the poles. Stick the dot sticker immediately on the end that produces a positive peak.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 6, Science, chapter 4: Exploring Magnets

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.