Experiments › Chemistry
Whose powder is it?
Mystery Powder
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a pinch of white powder help solve a jewelry safe mystery?
Show the answer
Every powder has a hidden chemical fingerprint. Today you measure conductivity, pH, fizzing, and melting point to identify unknown evidence.

Introduction
The Case of the Missing Jewelry
An open safe was discovered in an empty room, and valuable jewelry was gone. The only clue left behind on the table was a tiny spill of mystery white powder. To the eye, many white powders look identical: baking soda, powdered sugar, aspirin, starch, or citric acid. But forensic scientists never guess. By testing how the powder conducts electricity, its pH, how it reacts with acid, and the exact temperature it melts, we can find its true identity.
Driving question: Can we identify a mystery white powder by testing its chemical and physical properties?
What you will learn
Today you will find out
- I can explain the difference between physical and chemical properties.
- I can measure and compare the conductivity and pH of different powder solutions.
- I can identify which powders react chemically with acid to release gas.
- I can find the melting temperature of a solid from a graph.
- I can match evidence data to known substances to solve a forensic mystery.
Why it matters: Forensic chemists, pharmaceutical labs, and food inspectors test unknown powders every day to protect health and solve crimes.
Safety first
Laboratory Safety Rules
- Wear splash goggles and lab aprons at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hydrochloric acid (1.0 M HCl) causes severe burns. Only the teacher handles the acid bottle.
- The Melt Station heat block gets hotter than water that boils (up to 200 °C). Never touch the metal block.
- Never taste any laboratory powder or drink from lab glassware.
- Capillary tubes are thin glass. Handle them gently so they do not snap.
What you need
- Go Direct Conductivity Probe1 per group
- Go Direct pH Sensor1 per group
- Go Direct Melt Station1 or 2 per class · teacher
- glass capillary melting tubes2 to 3 tubes per group
- Test tubes and rack7 tubes (13 x 100 mm) in 1 rack
- white chemical powder7 labeled sample dishes
- 0.1 M Hydrochloric acid solution1 dropper bottle (1.0 M HCl) · teacher
- Distilled water wash bottle1 bottle per group
- Tablet running Graphical Analysis1 per group

Step 1 of 6
Prepare your 7 solution tubes
- Add 15 mL of distilled water into each test tube.
- Add a small pinch (about 0.1 g) of each powder to the correct tube.
- Stir each tube with a clean glass rod.
- All 7 test tubes are securely in the rack.
- You rinse the stir rod so powders do not mix.
- Wear goggles and blue gloves.
- 7 test tubes are labeled: Baking Powder, Baking Soda, Aspirin, Sucrose, Cornstarch, Citric Acid, and Mystery.
- Rinse the rod with distilled water between tubes.
Careful: A dirty stir rod contaminates the powders and gives false readings. Rinse the stir rod with distilled water between every tube. Wipe it dry.

Step 2 of 6
Measure solution conductivity
- Dip the Go Direct Conductivity Probe into the first test tube.
- When the reading stabilizes, tap Keep and type the powder name.
- Rinse the probe with distilled water between tubes. Repeat this test for all 7 tubes and the mystery tube. Tap Stop.
- Distilled water wash bottle is full.
- A waste beaker sits under the probe when you rinse it.
- Probe tip is completely submerged in each liquid.
- Tap Collect to start data collection in Graphical Analysis.
- Rinse the probe fully over the waste beaker with distilled water.
Careful: If you do not rinse the probe, ions transfer between tubes and give falsely high readings. Rinse the probe tip with distilled water before you insert it into each tube.

Step 3 of 6
Measure solution pH
- Dip the glass bulb into the first test tube.
- When steady, tap Keep and type the powder name.
- Rinse the glass bulb fully with distilled water between tubes. Measure all 7 tubes and the mystery tube. Tap Stop.
- pH sensor storage bottle is set safely aside.
- The delicate glass bulb at the tip is handled gently.
- Waste beaker is ready for rinses.
- Unscrew the storage bottle from the Go Direct pH Sensor and rinse the glass bulb with distilled water.
- Connect the pH sensor in Graphical Analysis and start a new data set.
- Rinse the glass bulb fully between each tube.
Careful: If the glass bulb hits the bottom of the tube, the electrode can crack. Lower the sensor gently into the tube. Do not hit the glass walls or bottom.

Step 4 of 6 Teacher does this
Add hydrochloric acid with your teacher
- Have your teacher add 10 drops of 1.0 M hydrochloric acid (HCl) to each test tube.
- Watch closely as the drops hit the liquid. Look for bubbles that fizz or foam.
- Stir gently with the clean rod and record whether each tube reacts.
- The adult wears purple nitrile gloves and goggles.
- Students keep hands back and wear safety goggles.
- 1.0 M HCl bottle is handled only by the adult.
Careful: 1.0 M HCl is corrosive and causes severe skin burns and eye damage. Only the adult dispenses acid drops. In case of skin contact, rinse with water immediately.

Step 5 of 6
Pack the capillary melting tube
- Press the open end of a clean capillary tube into dry mystery powder to push a little inside.
- Turn the tube with the sealed end down. Tap gently until powder packs 3 mm (about 1/8 inch) deep.
- Wipe any loose powder from the outside with a tissue.
- Capillary tube is handled gently so the glass does not snap.
- Powder is completely dry.
- Wear gloves and goggles.
- Take a clean glass capillary tube: one end is sealed and one end is open.
Careful: A hard tap on a hard desk can shatter the fragile glass tube. Tap gently upright. You can drop it down an empty straw to pack it safely.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level DP, Chemistry, chapter Structure 2.2: The covalent model
Versions and what each needs
- Whose powder is it?
Forensic Chemistry, 90 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Melt Station, Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.