Experiments › Biology

Why are cells so tiny?

Limits on Cell Size

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

An elephant and a tiny mouse side by side, with a glowing magnifying bubble showing their cells are the exact same size

Wonder

Why are elephants made of trillions of microscopic cells instead of one huge cell?

Show the answer

Every cell feeds through its outer skin. When a cell gets bigger, its inside outgrows its skin! Today you will prove why cells must stay tiny.

A large cell struggling to feed its deep interior compared to small cells feeding easily

Introduction

Why Are Cells So Tiny?

Look at an elephant and a mouse. The elephant is thousands of times heavier. Yet, an elephant kidney cell is almost the exact same size as a mouse kidney cell! Why cannot a living cell simply grow to the size of a football? Every cell must take in food and push out waste through its outer surface. In this experiment, you will use salty jelly cubes as cell models. A conductivity sensor will measure how fast salt escapes into water, revealing why big cells cannot survive.

Driving question: Why are all living cells microscopic instead of giant?

What you will learn

Today you will find out

  • I can calculate and compare the surface-area-to-volume ratio of different sized cubes.
  • I can show that dividing a solid into smaller pieces gives it more outside surface.
  • I can use a conductivity probe and tablet to measure how fast salt enters water.
  • I can explain why smaller cells exchange materials faster than larger cells.
  • I can explain how real organs fold their membranes to speed up absorption.

Why it matters: Understanding surface area explains how lungs take in oxygen, how intestines absorb food, and why living cells divide instead of swelling.

Safety first

Scientist Rules for Today

  • Wear safety goggles and nitrile gloves throughout the lab.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Sharp blade warning: Scalpels and razor blades are extremely sharp. An adult must cut the agar or directly supervise you.
  • Never eat or taste the agar cubes, even though they contain kitchen salt. Lab materials are never food.
  • Keep water at least 30 cm away from laptops and tablets.
  • Wipe up any spilled water immediately with paper towels to prevent slippery floors.

What you need

  • Go Direct Conductivity Probe1
  • Tablet running Graphical Analysis1
  • 600 mL beaker1
  • ring stand with clamp1 set
  • agar cubes3 cubes (2 cm each, salty)
  • glass stirring rod1
  • Distilled water wash bottle1 bottle (1 L)
  • ruler1 metric ruler
  • paper towel1 roll
  • safety goggles1 per person
Adult gloved hands slicing an agar cube with a scalpel on a cutting board

Step 1 of 7 Teacher does this

Prepare the three cube samples

  1. Get three identical 2 cm agar cubes.
  2. Leave Cube 1 whole (1 piece).
  3. Have an adult cut Cube 2 into 8 equal cubes (1 cm each) and Cube 3 into 64 equal cubes (0.5 cm each).
Stop and check
  • An adult handles the scalpel or closely supervises its use.
  • Agar rests flat on a firm board and not in your hand.
  • Fingers stay at least 5 cm away from the blade.

Careful: Scalpel blades can slip on wet agar and cause cuts. Slice straight downward onto a firm board. Only adults handle the sharp blade.

A student using a clear ruler to measure an agar cube next to a lab notebook with math tables

Step 2 of 7

Calculate surface area and volume

  1. Measure the side length of each piece with your metric ruler.
  2. Calculate the total surface area and total volume of each sample.
  3. Divide surface area by volume to find the surface-to-volume ratio.
Stop and check
  • Wear gloves when you touch agar cubes.
  • Keep agar cubes on their clean labeled trays.
  • Surface area formula: area of 1 face times 6 faces times number of pieces.
  • Volume formula: length times width times height times number of pieces.

Careful: If you confuse cm and mm, you get incorrect ratio numbers. Use centimetres for all measurements. Check your math with your lab partner.

Conductivity probe clamped above the bottom of a 600 mL beaker filled with 300 mL water

Step 3 of 7

Clamp probe and prepare beaker

  1. Attach the utility clamp to the ring stand and clamp the Go Direct Conductivity Probe straight down.
  2. Pour exactly 300 mL of distilled water into your 600 mL beaker.
  3. Lower the probe until its tip is in water, exactly 2 cm above the beaker bottom.
Stop and check
  • The ring stand base rests flat and steady on the lab bench.
  • The clamp holds the probe firmly but does not crush the plastic body.
  • The probe tip is 2 cm above the bottom to leave room to stir.

Careful: If the probe rests on the bottom, the glass rod can hit it or block water flow through its slot. Keep the probe tip 2 cm above the beaker bottom so liquid circulates freely.

Student gently stirring water with a glass rod as a whole agar cube dissolves at the bottom

Step 4 of 7

Run 1: Test the single whole cube

  1. Place the whole 2 cm agar cube into the beaker.
  2. Immediately tap Collect in Graphical Analysis.
  3. Stir continuously and gently with your glass rod until collection stops at 120 seconds.
Stop and check
  • Pure distilled water is in the beaker (initial value under 15 µS/cm).
  • The rod is glass. Stir gently and do not strike the beaker walls.
  • Do not bump the probe with the glass rod.

Careful: If you stir vigorously, you can splash water onto the tablet or hit the probe. Stir with smooth, steady circles around the outside of the probe.

Tablet screen showing a linear curve fit on the conductivity graph with slope m highlighted

Step 5 of 7

Find the rate of ion exchange

  1. In Graphical Analysis, drag your finger across the straightest part of the graph line.
  2. Tap Graph Tools. Choose Apply Curve Fit. Select Linear. Tap Apply.
  3. Write the slope m (rate in µS/cm/s) from the equation y = mx + b into your table.
Stop and check
  • The 120-second run has finished.
  • The highlighted region covers the straight upward portion of data.

Careful: If you select curved ends, you can get an inaccurate rate slope. Select the middle region where the line is straightest.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

ICSE (CISCE)
  • Direct Class 9, Biology, chapter 2: The Cell
  • Direct Class 10, Biology, chapter 1: Cell An Independent Unit of Life
Cambridge AS & A Level
  • Direct Level AS & A Level, Biology, chapter 4: Cell membranes and transport
IB Diploma
  • Direct Level DP, Biology, chapter B2.3: Cell specialization

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.