Experiments › Chemistry

Why are some drain cleaners stronger?

NaOH

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two colourful plastic bottles of household drain cleaner standing side by side near a kitchen sink

Wonder

Why can two bottles of drain cleaner have different strengths?

Show the answer

Solid pellets soak up moisture directly from the air like a sponge, adding hidden water weight. Scientists call the real chemical strength concentration, and today you will measure it.

White chemical pellets on a watch glass attracting moisture droplets from surrounding air

Introduction

The Sponge Chemical

Sodium hydroxide is one of the most useful bases on Earth. It helps make soap, paper, and drain cleaners. But solid sodium hydroxide has a tricky secret: it grabs invisible water vapour straight out of the air! If you weigh 4 grams of solid pellets, some of that weight is just trapped water. That means you cannot know the exact strength of the liquid just by weighing it. To find its real strength, we must test it against a pure, stable acid standard.

Driving question: Why does a factory test its cleaning chemicals before selling them?

What you will learn

Today you will discover

  • I can explain why we must test a base solution to find its true strength.
  • I can spot the steep pH jump on a graph when an acid is neutralized.
  • I can find the exact volume where acid and base cancel each other out.
  • I can safely set up the sensors and Stir Station for drop-by-drop testing.
  • I can give examples of real industries that verify chemical concentrations.

Why it matters: Medicine factories, soap makers, and food labs must know the exact strength of their chemicals to keep products safe.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab aprons, and protective gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Solid sodium hydroxide causes severe skin burns. Only your teacher handles solid pellets and prepares the stock.
  • Never taste or touch any lab liquid. Sodium hydroxide is corrosive to skin and eyes.
  • Keep all liquids at least 30 cm away from the tablet and electronics.
  • If any liquid splashes on skin, rinse immediately under tap water for 15 minutes. Alert an adult.
  • Look for the ADULT NEEDED badge on teacher-managed steps.

What you need

  • Go Direct pH Sensor1
  • Go Direct Drop Counter1
  • Stir Station with magnetic stir bar1
  • Plastic 60 mL reagent reservoir with dual valves1
  • 0.10 M Sodium hydroxide solution (prepared by adult)70 mL · teacher
  • Solid potassium hydrogen phthalate (pre-weighed 0.20 g)0.20 g in weighing dish
  • 100 mL beaker and 250 mL waste beaker2 beakers
  • Ring stand with utility clamp1 set
  • Distilled water wash bottle1
  • Tablet running Graphical Analysis app1
Adult gloved hands swirling a glass flask as white pellets dissolve

Step 1 of 9 Teacher does this

Adult prepares the target base solution

  1. An adult weighs 4.0 g of solid sodium hydroxide pellets in a fume area.
  2. The adult dissolves the pellets in distilled water and makes 1.0 L of liquid base.
  3. You watch from a safe distance as the solid completely dissolves.
  4. The flask feels warm because sodium hydroxide releases heat when it dissolves.
Stop and check
  • The adult wears heavy nitrile gloves and chemical splash goggles.
  • Solid pellets are kept away from moisture until mixed.
  • Students stand at least 1 metre back.

Careful: Solid NaOH causes rapid, painful skin burns and permanent eye injury if splashed. Only an adult handles solid pellets and concentrated solutions. Keep vinegar or eyewash nearby.

Student gloved hand pouring white powder into a 100 mL beaker

Step 2 of 9

Dissolve the standard acid sample

  1. Pour 40 mL of distilled water into your clean 100 mL beaker.
  2. Add the pre-weighed 0.20 g of white KHP standard acid powder.
  3. Gently drop the white magnetic stir bar into the beaker.
  4. Swirl gently until all white crystals dissolve completely.
Stop and check
  • You wear safety goggles and blue gloves.
  • The beaker sits flat on the table, not on an edge.
  • Distilled water was measured with a clean graduated cylinder.

Careful: If you drop the stir bar too hard, you can crack the glass beaker bottom. Tilt the beaker slightly and slide the magnetic stir bar down the inner wall gently.

Drop Counter mounted to the ring stand directly above the Stir Station platform

Step 3 of 9

Assemble the Drop Counter and Stir Station

  1. Place the Stir Station flat on your bench.
  2. Attach the vertical ring stand rod firmly to the back of the Stir Station.
  3. Slide the Go Direct Drop Counter onto the rod and tighten its knob.
  4. Place the beaker of dissolved acid on the white round stir plate.
Stop and check
  • The Stir Station cord is tucked away from walkways.
  • The ring stand rod is screwed on tight and does not wobble.

Careful: A loose clamp can slip down and smash the glassware below. Hand-tighten the clamp screws firmly before you put glass underneath.

Student inserting pH probe through the Drop Counter slot into the beaker

Step 4 of 9

Insert and position the pH Sensor

  1. Unscrew the storage bottle from the pH sensor and rinse the tip with distilled water.
  2. Slide the pH sensor shaft down through the large hole in the Drop Counter.
  3. Position the glass bulb tip deep in the liquid. Turn on the Stir Station knob to stir gently.
Stop and check
  • Storage bottle cap is safe and upright on your tray.
  • Sensor tip was rinsed over the waste beaker.
  • The glass bulb tip is positioned above the bottom.
  • Make sure the stir bar will not strike the glass bulb while it spins!

Careful: The magnetic stir bar can hit the thin glass sensor bulb and shatter it while it spins. Keep the sensor bulb at least 5 mm away from the path of the stir bar.

Adult pouring base solution into the upper reservoir clamped above the Drop Counter

Step 5 of 9 Teacher does this

Adult fills the reagent reservoir

  1. Turn both blue valve handles sideways to close them. Clamp the reservoir to the ring stand above the Drop Counter window.
  2. The adult pours about 60 mL of the prepared sodium hydroxide base into the top.
  3. Temporarily set aside the acid beaker. Place a 250 mL waste beaker below the tip. Open both valves to flush air bubbles.
Stop and check
  • Both valve handles are horizontal (closed).
  • Waste beaker is placed directly under the reservoir tip.
  • The adult wears purple gloves and splash goggles.

Careful: Base liquid that leaks past an open valve can spill on hands or tables. Make sure the valves are closed before the adult pours. The adult must pour all base liquid.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.