Experiments › Chemistry
Why did the medicine tablets crack?
Tablet Testing
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why would brand new medicine tablets break apart in a sealed bottle?
Show the answer
Pure medicines have strict crystal recipes. If an unexpected chemical creeps in, the whole crystal weakens. Today you use a precision heat station to discover the secret flaw.

Introduction
The Mystery of the Cracking Tablets
Customers opened new bottles of pain relief medicine and found crumbling tablets. Every pure solid melts at an exact, sharp temperature. When an unwanted chemical mixes in, the solid melts at a lower temperature and turns brittle. Today, you will measure melting points to find out what ruined the tablets.
Driving question: Why did the medicine tablets crack inside their bottles?
What you will learn
Goals for this lab
- I can explain what happens to the melting point of a pure substance.
- I can observe the melting range of pure and mixed solids.
- I can pack a capillary tube with solid powder safely.
- I can find the melting temperature on a real-time graph.
- I can explain how factories use melting points to test product purity.
Why it matters: Pharmaceutical factories and forensic labs check melting points daily to ensure medicines are completely pure and safe.
Safety first
Laboratory Safety Rules
- Wear safety goggles, lab coats, and protective gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The Melt Station heat block reaches over 180°C. Never touch the metal heat slots.
- Glass capillary tubes are very thin and fragile. Never squeeze or force them into slots.
- Never taste or swallow any chemical powders, even if they look like common medicine.
- Wash your hands fully with soap and water after you complete the lab.
What you need
- Go Direct Melt Station1 per station
- Tablet running Graphical Analysis1 per group
- glass capillary melting tubes6 per group
- mortar and pestle1 per group
- white chemical powder3 small weigh boats (aspirin, acetaminophen, tablet sample)
- laboratory spatula1 per group
- Splash goggles and nitrile gloves1 set per person

Step 1 of 10 Teacher does this
Power on the Melt Station
- The teacher plugs the Melt Station power cord into an electrical wall outlet.
- Turn the dial to the cool fan symbol to test that the fan spins.
- The bench surface is completely dry.
- The power cable is safely tucked away from walkways.
- The Melt Station control knob is in the Off position.
- Check that the temperature dial is turned to the Off position.
- Students keep hands clear of the power cable.
Careful: Mains electricity cables can present shock or trip hazards in a wet lab. Only the adult connects mains electrical power.

Step 2 of 10
Connect Melt Station to your tablet
- Open the Graphical Analysis app on your tablet.
- Press the power button on the Go Direct Melt Station once.
- Tap Sensor Data Collection, find your Melt Station, and tap Connect.
- Bluetooth is enabled on your tablet.
- The LED status light on the sensor blinks gently.
- The screen displays a live temperature reading in Celsius.
Careful: A connection to the wrong classroom sensor gives incorrect temperature data. Match the sensor serial code on the back of your Melt Station.

Step 3 of 10
Grind samples to a fine powder
- Place a small scoop of pure aspirin crystals into the clean mortar.
- Use the pestle to crush the crystals into a very fine flour-like powder.
- Repeat with fresh mortars for pure acetaminophen and the cracked tablet sample.
- Mortar and pestle are clean and completely dry.
- Goggles and gloves are securely on.
Careful: Dust can blow toward your face if you crush too aggressively. Grind with gentle circular motions. Do not pound the mortar.

Step 4 of 10
Pack the capillary tubes
- Press the open end straight down into the small pile of aspirin powder.
- Invert the tube so the sealed end points down.
- Gently tap the sealed end on the bench to pack 2 to 3 millimetres of powder.
- The tube is not cracked or chipped.
- You hold the tube gently between your fingers.
- Take a capillary tube and confirm one end is sealed glass.
Careful: If you tap glass too hard on a stone bench, you can snap the fragile capillary tube. Tap gently against a rubber mat or paper towel pad on the table.

Step 5 of 10
Prepare tubes for all three samples
- Repeat the pack procedure for pure acetaminophen in a second tube.
- Pack a third capillary tube with the mystery cracked tablet powder.
- Wipe the outside of each tube clean with a dry tissue.
- All three tubes have 2 to 3 mm of packed powder.
- Cards are labelled: Aspirin, Acetaminophen, Tablet Sample.
- Keep each tube on a clearly labelled paper index card so you do not mix them up.
Careful: If you mix up the tubes, you get incorrect and invalid conclusions. Lay each tube across its correct labelled index card.
5 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
Versions and what each needs
- Why did the medicine tablets crack?
AP Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Melt Station
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.