Experiments › Chemistry and Physics

Why did the rocket bottle burst?

Avogadros Law and Order

Grades 7-8Chemistry and Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

A burst clear plastic soda bottle on an outdoor launch pad with a notebook beside it

Wonder

Can a smaller tabletop model solve a mystery about a burst bottle rocket?

Show the answer

A plastic bottle rocket burst during a science launch. Today you build a tabletop model to uncover how much pressure burst it, and whether the gas inside mattered.

A plastic bottle water rocket sitting pressurized on a launch stand in an open grassy field

Introduction

The Rocket Bottle Mystery

During a science club launch, a 2-litre plastic bottle rocket suddenly burst before take-off. The bottle has a safe pressure limit of 150 psi. Some wondered if students used too many bicycle pump strokes, while others claimed effervescing tablets made a different, dangerous gas. Testing a full-sized bottle to explosion is unsafe. Instead, you will act as forensic scientists: test a safe glass flask scale model, inject equal puffs of air and carbon dioxide, and find the real cause.

Driving question: Why did a bottle rocket burst, and does using carbon dioxide change the pressure inside?

What you will learn

Your Mission Objectives

  • I can explain why adding gas makes pressure go up in a straight line.
  • I can compare pressure changes when adding air versus carbon dioxide.
  • I can use my model to predict when a plastic bottle will burst.
  • I can assemble gas tubing and valves safely to measure pressure without leaks.
  • I can explain how gas pressure models help investigate engineering failures.

Why it matters: Engineers and forensic scientists use scale models and gas laws to design spacecraft, test scuba tanks, and prevent pressure accidents.

Safety first

Forensic Lab Safety Rules

  • Wear safety goggles and lab gloves throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never over-tighten glass fittings or force the syringe plunger.
  • Do not shake the Alka-Seltzer generator flask when the stopper seals the flask.
  • Keep water and reaction flasks at least 30 cm away from tablets and sensors.
  • If a stopper pops off, stop, lower the syringe, and call your teacher.
  • Wash your hands with soap and water after you clean up.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • Tablet running Graphical Analysis Pro1
  • 125 mL Erlenmeyer flasks2
  • 20 mL gas syringe with luer tip1
  • Rubber stoppers with two-way valves and tubing2 sets
  • 10 mL graduated cylinder1
  • Alka-Seltzer tablet (quartered)1 tablet (cut into quarters)
  • Distilled water wash bottle1 bottle
  • Splash goggles and nitrile gloves1 set per student
Student hand holding temperature probe in room air next to tablet

Step 1 of 10

Record the room temperature

  1. Switch on the Go Direct Temperature Probe. Connect it to Graphical Analysis.
  2. Hold the probe tip in the open room air away from heat sources or drafts.
  3. Wait 10 seconds until the reading settles. Write the room temperature in your notes.
  4. Disconnect the temperature probe so you are ready to connect the pressure sensor.
Stop and check
  • Tablet is turned on with Bluetooth active.
  • Temperature probe tip is clean and dry.

Careful: If you hold the metal tip with bare fingers, you warm the probe and get a false room temperature. Hold the probe only by its plastic handle. Let the metal stem sit in air.

Connecting clear tubing from rubber stopper to the gas pressure sensor

Step 2 of 10

Assemble the test flask model

  1. Take one clean, empty 125 mL Erlenmeyer flask.
  2. Firmly press the two-hole rubber stopper into the flask neck with a gentle twist.
  3. Connect one stopper stem to the Go Direct Gas Pressure Sensor with the clear tube.
  4. Screw the white two-way valve onto the second stopper stem.
  5. Turn the valve handle open to the air for now.
Stop and check
  • Flask is dry and free of cracks.
  • Stopper is seated snugly and cannot wobble.

Careful: If you push glass tubes roughly, you can snap glass or damage luer-lock threads. Grip the stopper firmly and twist gently. Tighten plastic luer locks finger-tight only.

Student closing the two-way valve on the stopper assembly

Step 3 of 10

Record initial baseline pressure at 0 mL

  1. Turn the valve handle sideways to close the two-way valve on your flask.
  2. Watch the live pressure meter on the screen.
  3. When the reading stays steady, tap Keep.
  4. Type 0 for Total Volume Added. Tap Keep Point.
  5. This point records the natural room air pressure trapped inside your flask.
Stop and check
  • The valve is fully turned perpendicular to the tube (closed).
  • No syringe is connected yet.

Careful: If you leave the valve open, gas leaks and baseline readings change. Make sure that you turn the handle fully across the valve stem.

Student pressing syringe plunger to inject air into the sealed flask

Step 4 of 10

Inject 5 mL of air into the flask

  1. Pull the syringe plunger back to draw exactly 5 mL of room air.
  2. Twist the syringe tip securely onto the valve on the flask.
  3. Turn the valve handle open. Align the handle with the tube.
  4. Smoothly push the plunger down all the way to 0 mL to inject the air.
  5. Turn the valve handle sideways to close it, then untwist the syringe.
Stop and check
  • Plunger starts exactly at the 5 mL mark.
  • Close the valve after injection before you remove the syringe.

Careful: If you detach the syringe while the valve is open, the injected air rushes back out with a hiss. Always close the valve first before you unscrew the syringe.

Tablet screen showing the second data point plotted at 5 mL

Step 5 of 10

Record pressure at 5 mL total added

  1. Wait 5 seconds for the pressure reading to stabilize.
  2. Tap Keep on your screen.
  3. Enter 5 for Total Volume Added. Tap Keep Point.
  4. Notice the new data dot appear higher on your graph screen.
Stop and check
  • The valve is tightly closed.
  • The pressure number stays steady.

Careful: If you tap Keep while the number still moves, you create an inaccurate data point. Wait until the number stops drift before you record.

5 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

IB Diploma
  • Direct Level DP, Chemistry, chapter Structure 1.4: Counting particles by mass: The mole

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.