Experiments › Physics

Why do crossed sunglasses go dark?

Polarization of Light

Grades 7-8Physics2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two pairs of sunglasses overlapping where the overlapped lens turns dark black

Wonder

How can two completely clear sheets turn totally black when stacked together?

Show the answer

Light waves wiggle in all directions. Special filters let only one wiggle direction through. Turn them sideways, and they block all light!

Two circular optical filters being rotated until their overlap blocks light

Introduction

The Magic of Crossed Filters

Have you ever looked through two pairs of polarized sunglasses at once? Look through both, and everything seems normal. But twist one pair sideways by 90 degrees, and the lenses turn pitch black! No paint was added, and neither lens is broken. How can two clear pieces of plastic block light completely? Today, you will use precision optics and a digital light sensor to crack the mystery.

Driving question: Why do two clear plastic lenses turn pitch black when you twist one of them?

What you will learn

Today you will find out

  • I can explain what polarized light means using a picket-fence model.
  • I can observe how turning a filter makes light brighter or dimmer.
  • I can find which angles give the brightest light and which angles block it.
  • I can set up the track, line up filters, and record light intensity at each angle.
  • I can explain how polarized sunglasses and screen filters block unwanted glare.

Why it matters: Polarization makes car windshields safer, gives pilot sunglasses glare protection, and powers everyday phone screens.

Safety first

Lab Rules for Today

  • Do not stare directly into the bright LED light source at close range. It can dazzle your eyes.
  • Handle the dynamics track with care. Keep hands clear when you slide mounts along the aluminium rail.
  • Never drop or scratch the polarizer disks. Scratches scatter light and ruin your readings.
  • Keep cables neatly on the table so nobody trips or drags the track to the floor.
  • Purple gloves = teacher does it. Blue gloves = you do it.

What you need

  • Vernier Dynamics Track (1.2 m)1
  • Optics Expansion Kit1 light source assembly with power supply
  • Mirror Set for OEK2 Adjustable Analyzers with degree dials
  • Go Direct Light and Color Sensor1
  • Light sensor holder and cradle from Optics Expansion Kit1
  • Tablet running Graphical Analysis1
Student clipping the LED light source to the 20 cm mark on the dynamics track

Step 1 of 7

Set up the track and light source

  1. Clip the light source assembly onto the track at the 20 cm mark.
  2. Turn the front disk to its open circle to uncover the white LED.
  3. Connect the power adapter. Turn on the light source.
Stop and check
  • The track sits firmly on the table and will not rock.
  • Power cord is routed neatly away from walkway areas.
  • Nobody stares straight into the open LED from up close.
  • The aluminium dynamics track is placed flat and steady on the lab bench.
  • Wait 15 minutes before you measure so the LED brightness becomes steady.

Careful: The LED beam is intensely bright up close and can dazzle your vision. Look at the track from the side, never look directly into the bare LED.

Student setting the first polarizer ring to 0 degrees on the track

Step 2 of 7

Mount the first polarizer at 0 degrees

  1. Rotate the pointer ring of the first Adjustable Analyzer to 0 degrees.
  2. Clip it onto the track right next to the light source (around 25 cm).
  3. Turn the degree scale to face downstream toward where you will work.
Stop and check
  • The filter ring turns smoothly without force.
  • The polarizer film is clean and free of fingerprints.

Careful: If you touch the clear film, you leave oily finger marks that scatter light. Touch only the outer black plastic rim and the degree ring.

Two filter holders mounted on the track in line with the light beam

Step 3 of 7

Mount the second filter (the analyzer)

  1. Clip the second Adjustable Analyzer onto the track around the 35 cm mark.
  2. Turn its degree scale to face toward the sensor.
  3. Look through both filters and gently twist the dial.
Stop and check
  • Both filter holders stand upright and square to the track.
  • The degree markings on both filters are clearly visible.
  • Light passes directly through both filters.
  • Notice how the view brightens and darkens as the angle changes.

Careful: If you tilt the filter holder, light passes through at an angle and changes the path length. Press firmly down until the mount snaps straight onto the track rails.

Student placing the Go Direct Light and Color Sensor into the track cradle

Step 4 of 7

Mount the Go Direct Light and Color Sensor

  1. Attach the sensor cradle to the light sensor bracket.
  2. Clip the bracket onto the track downstream of the analyzer (near 45 cm).
  3. Slide the Go Direct Light and Color Sensor horizontally into the cradle.
Stop and check
  • The sensor sits firmly in its cradle and does not wobble.
  • The sensor aperture lines up directly with the centre of the filters.
  • The small light sensor aperture on the end points straight at the light source.
  • Keep parts close together to minimize stray room light that enters the sensor.

Careful: If the sensor is bumped during rotation, the distance changes and ruins the graph. Clamp the bracket securely to the track rail. Do not nudge it while you turn dials.

Tablet screen showing Graphical Analysis connected to Go Direct Light and Color Sensor

Step 5 of 7

Connect sensor to Graphical Analysis

  1. Press the power button on the Go Direct Light and Color Sensor.
  2. Open Vernier Graphical Analysis on your tablet or laptop.
  3. Tap Sensor Data Collection. Find your sensor name. Tap Connect.
Stop and check
  • The sensor LED flashes green to show active Bluetooth.
  • The Graphical Analysis app detects the sensor.
  • Confirm the sensor measures Illuminance in lux on the live meter.

Careful: If you connect to another group's sensor by accident, you get unclear readings. Match the serial number printed on the back of your sensor box.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 12, Physics, chapter 2: Wave Optics
Cambridge AS & A Level
  • Direct Level AS & A Level, Physics, chapter 7: Waves

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.