Experiments › Physical Science

Why do distant lights look dim?

How Bright is Light

Grades 7-8Physical Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A lone streetlight glowing in the night with light spreading out and fading into the distance

Wonder

Why does a bright car headlight look like a tiny firefly from a kilometer away?

Show the answer

Light spreads out in every direction as it travels. Today you will measure how fast brightness fades and discover the geometric rule behind it.

A flashlight shining on a wall, showing a small bright circle close up and a huge dim circle far away

Introduction

Why Do Lights Look Dimmer Far Away?

Have you ever held a flashlight right up against a wall? The beam is small, sharp, and blindingly bright. Back up across the room, and the beam covers the whole wall, but the glow is much weaker. The bulb did not lose power. Instead, the same amount of light spread across a much bigger area. Today, you will use a Go Direct Light Sensor to measure this fading effect with precision. You will discover the exact mathematical pattern that controls light everywhere in the universe.

Driving question: Why does a flashlight beam look so bright up close but dim across the street?

What you will learn

Your Mission Today

  • I can use a light sensor to measure how bright a lamp is at different distances.
  • I can subtract background light to find the true light from the bulb.
  • I can explain why light gets four times dimmer when distance doubles.
  • I can test whether my data matches the one-fourth inverse square pattern.
  • I can connect the spread of light to how flashlights and spacecraft solar panels work.

Why it matters: Engineers designing streetlights, photographers setting studio flashes, and space scientists powering probes to Jupiter all use this rule.

Safety first

Lab Rules for Today

  • Wear safety goggles throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Incandescent bulbs and the foil enclosure become very hot during use. Never touch the bulb or the top of the box.
  • Look for the ADULT NEEDED badge. Only your teacher adjusts the lamp or opens the foil box.
  • Keep cables neatly on the table so nobody trips in the darkened classroom.
  • Let the lamp cool fully before you pack it away.

What you need

  • Go Direct Light and Color Sensor1
  • Tablet running Graphical Analysis1
  • ring stand2
  • utility clamp2
  • meter stick1
  • roll of tape1 roll of masking tape
  • desk lamp with light bulb1 lamp with 60 W bulb · teacher
  • sheet of aluminum foil1 foil enclosure box with 5 mm pinhole · teacher
  • safety goggles1 pair per person
Student hands taping a wooden meter stick flat on a clean table

Step 1 of 7

Tape down your meter stick track

  1. Place the wooden meter stick flat across the centre of your lab bench.
  2. Use two strips of tape to fix both ends securely to the table.
  3. Check that the 0 cm mark is at one end and the numbers increase cleanly toward your side.
Stop and check
  • Bench top is clear of books and clutter.
  • The meter stick lies completely flat.

Careful: A loose meter stick shifts when you move the sensor. This causes inaccurate distance measurements. Press tape down firmly at the 0 cm and 100 cm ends.

Teacher placing a foil box over a lamp at the 0 cm mark on a meter stick

Step 2 of 7 Teacher does this

Set up the lamp and foil enclosure

  1. Have your teacher place the lamp at the 0 cm mark of the meter stick.
  2. Enclose the lamp inside the aluminum foil box. Point the hole down the meter stick.
  3. Place the loose foil lid on top. Do not crimp the lid so hot air can escape.
Stop and check
  • Lamp is turned OFF during setup.
  • Bulb glass does not touch foil directly.
  • The power cord passes safely through the rear slot and does not pull.
  • The 5 mm pinhole must face directly along the meter stick, level with the bulb filament.

Careful: Incandescent bulbs get extremely hot and can overheat if enclosed tightly. Hot foil causes burns if you touch it. Only the teacher positions the lamp and lid. Keep the lid loose so heat vents freely.

Student clamping the light sensor on a ring stand lined up with the pinhole at 10 cm

Step 3 of 7

Clamp and align the light sensor

  1. Clamp the Go Direct Light and Color Sensor in the utility clamp on your second ring stand.
  2. Position the sensor tip directly over the 10 cm line on your meter stick.
  3. Aim the front of the sensor straight at the pinhole so it catches the light beam head-on.
Stop and check
  • The base of the ring stand rests flat on the bench.
  • Utility clamp thumbscrew is tightened firmly around the sensor.
  • Adjust clamp height until the sensor aperture is at the exact same height as the foil pinhole.

Careful: If the clamp slips, the sensor could drop or point at the table instead of the light. Tighten the clamp thumbscrew gently by hand until snug. Do not over-tighten.

Teacher switching on the lamp inside the foil box in a darkened room with a glowing pinhole

Step 4 of 7 Teacher does this

Darken room and turn on the lamp

  1. Have your teacher draw the window blinds and turn off the main ceiling lights.
  2. Have your teacher switch ON the lamp inside the foil enclosure.
  3. Watch the front of the box. Look for a bright round beam that shines through the pinhole.
Stop and check
  • Aisle paths are clear before you turn off the room lights.
  • All students are seated and ready.
  • Students remain in their assigned seats so body shadows do not change stray light.

Careful: If you walk in a dark room, you can trip over cords or hit ring stands. Stay at your lab station. Only the teacher moves around to switch lights.

Student hand carefully sliding the ring stand base along the meter stick while tapping the tablet screen

Step 5 of 7

Measure light intensity from 10 cm to 40 cm

  1. In Graphical Analysis, tap Collect to start. At 10 cm, tap Keep. Type 10. Tap Keep Point.
  2. Slide the sensor stand to 15 cm, wait until stable, tap Keep, type 15, and tap Keep Point.
  3. Repeat every 5 cm (20, 25, 30, 35, 40 cm) until you store seven points. Tap Stop.
Stop and check
  • Keep hands clear of the hot foil box.
  • Slide the ring stand by its base. Do not pull the sensor cord.
  • Wait until the lux number stabilizes. Make sure that the alignment is correct at each distance.

Careful: If you tilt the sensor when you move it, readings become low because the sensor misses the central beam. Always keep the sensor perfectly level and pointed straight at the pinhole.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 7, Science, chapter 11: Light: Shadows and Reflections
  • Direct Class 8, Science, chapter 13: Light
  • Related Class 9, Science, chapter 12: Improvement in Food Resources
ICSE (CISCE)
  • Direct Class 6, Physics, chapter 9: Light and General Terms used in Understanding Light
Cambridge AS & A Level
  • Direct Level AS & A Level, Physics, chapter 25: Astronomy and cosmology

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.