Experiments › Chemistry

Why do liquids push as they evaporate?

Vapor Pressure

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A sealed plastic bottle containing liquid showing tiny outward pressure arrows

Wonder

Why does a bottle of rubbing alcohol hiss when you open it?

Show the answer

Liquids evaporate even at room temperature. In a closed container, the trapped gas particles bounce and push outward. Today you will measure that invisible push.

A thin layer of hand sanitiser evaporating quickly on a wooden school desk

Introduction

The Push of Evaporating Liquid

When you leave a puddle of hand sanitiser on your desk, it disappears. Its particles escape into the air. But what happens if the liquid is trapped inside a sealed container? The particles cannot escape. They bounce off the walls and create an outward push called vapor pressure. In this experiment, you will trap evaporating liquid and measure the exact push of its trapped vapor.

Driving question: Why does a closed container of liquid build up pressure even when nobody heats it?

What you will learn

Today you will find out

  • I can explain how an evaporating liquid creates vapor pressure.
  • I can spot when pressure levels off into a steady balance.
  • I can calculate vapor pressure from total pressure and air pressure.
  • I can assemble an airtight flask setup with valves and tubing.
  • I can give everyday examples where vapor pressure matters.

Why it matters: Engineers designing fuel tanks, medicine sprays, and aerosol cans must understand vapor pressure so containers do not burst or leak.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Denatured ethanol is flammable and poisonous. Keep it away from heat, sparks, and open flames.
  • Do not breathe ethanol vapors directly or touch the liquid with bare skin.
  • Only an adult measures, handles, and injects ethanol with the syringe.
  • Handle all glassware gently. Keep the water bath steady on the table.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • 125 mL Erlenmeyer flask1 (clean and dry)
  • Two-hole rubber stopper with valve and tubing1 set
  • plastic syringe1 (20 mL) · teacher
  • 1 L beaker1
  • clear solution in a reagent bottle5 mL denatured ethanol · teacher
  • Tablet running Graphical Analysis1
  • Splash goggles and nitrile gloves1 set per person
A 1 L beaker filled with water containing a temperature probe

Step 1 of 7

Assemble the water bath

  1. Fill the 1 L beaker with about 800 mL of room-temperature tap water.
  2. Place the Go Direct Temperature Probe into the water bath.
  3. Check the temperature on your tablet. It should stay steady around 20 to 23 °C.
  4. The water bath keeps the flask at a constant temperature throughout the test.
Stop and check
  • Water is at room temperature, not hot or ice-cold.
  • The beaker sits firmly in the middle of the table, away from edges.

Careful: Do not spill water near electronic tablets or sensor ports. Pour water slowly. Keep the tablet at least 30 cm away from the beaker.

Student inserting rubber stopper into dry Erlenmeyer flask with tubing attached

Step 2 of 7

Connect tubing and stopper to the flask

  1. Check that the 125 mL flask is completely dry inside.
  2. Connect the clear plastic tube from the stopper to the Gas Pressure Sensor with a half-turn.
  3. Make sure that you open the two-way valve on the stopper.
  4. Twist the rubber stopper firmly into the neck of the flask to make sure that the seal is airtight.
Stop and check
  • The Erlenmeyer flask is dry inside.
  • The stopper fits snugly. Do not force the stopper or crack the glass neck.

Careful: A loose stopper lets air leak out. This causes incorrect pressure readings. Twist the stopper gently while you press down to seat it securely.

Erlenmeyer flask submerged in beaker water bath with stopper above water line

Step 3 of 7

Submerge the flask in the water bath

  1. Lower the sealed flask into the 1 L beaker water bath.
  2. Keep the entire flask body submerged in the water, as shown in the diagram.
  3. Leave the two-way valve open to the room air for 30 seconds so temperatures match.
  4. After 30 seconds, close the two-way valve completely.
Stop and check
  • Water does not overflow the 1 L beaker when the flask enters.
  • The two-way valve stays above the water line so no water enters the flask.

Careful: Water in the valve or flask will ruin the experiment. Keep the top of the stopper and valve dry above the water surface.

Teacher threading a syringe containing 3 mL ethanol onto the stopper valve

Step 4 of 7 Teacher does this

Adult loads ethanol into the syringe

  1. An adult puts on gloves and draws exactly 3 mL of ethanol into the 20 mL syringe.
  2. With the two-way valve closed, thread the syringe securely onto the valve.
  3. Students stand back and observe. Do not touch the ethanol bottle.
  4. The sealed flask is now ready for baseline measurement.
Stop and check
  • No open flames or hot plates anywhere in the room.
  • Close the ethanol stock bottle tightly after you remove liquid.
  • Make sure the valve is closed before you attach the syringe.

Careful: Denatured ethanol is flammable and irritates eyes and skin. Ethanol spills create hazardous fumes. Only the adult measures ethanol. Keep syringe upright and screw tightly into the valve.

Tablet screen showing first 10 seconds of flat pressure data at 98.3 kPa

Step 5 of 7

Record baseline air pressure

  1. Tap Collect on the tablet to begin data collection.
  2. Watch the pressure reading for the first 10 seconds. Do not touch the apparatus.
  3. The reading should stay almost perfectly flat near 98 to 101 kPa.
  4. This flat line is the atmospheric pressure of the air trapped inside your flask.
Stop and check
  • Nobody touches or shakes the beaker or flask.
  • The syringe valve is still closed.

Careful: If you bump the flask, false pressure jumps appear on the graph. Keep hands off the glassware while you record the baseline.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 11, Chemistry, chapter 6: Equilibrium
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 5: States of matter

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.