Why do mixed liquids warm up?
Enthalpy
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can mixing two cool liquids create instant heat?
Show the answer
When an acid meets a base, they cancel out and release hidden chemical heat. Today you will trap and measure that heat jump.

Introduction
The Heat Hidden in Clear Liquids
Imagine pouring two clear, cool liquids together. Neither liquid is hot. Yet seconds after they touch, the mix gets noticeably warm. Where did that heat come from? When an acid meets a base, they break old bonds and make new ones. This chemical reaction sets trapped energy free. Today you will trap this released heat inside an insulated cup and measure the exact jump using a digital temperature sensor.
Driving question: Can mixing two room-temperature liquids create heat out of nowhere?
What you will learn
Today you will find out
- I can explain why an acid and a base release heat when they mix.
- I can explain how an insulated cup traps reaction heat.
- I can track baseline and peak temperatures on a real-time graph.
- I can calculate the temperature jump from my lab graph.
- I can follow safety rules around acids and bases.
Why it matters: Engineers design self-heating food pouches and hand warmers using reaction heat. Chemical plants also control reaction heat to keep factory tanks safe.
Safety first
Lab Rules for Acids and Bases
- Wear chemical splash goggles, protective lab aprons and gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- 1.00 M hydrochloric acid and 1.05 M sodium hydroxide cause severe skin and eye damage.
- An adult dispenses and pours the acid and base solutions.
- If any chemical touches skin, rinse immediately with cold water for 15 minutes and tell the teacher.
- Keep tablet and sensor cables at least 30 cm away from all open liquids.
- Wash your hands with soap and water at the end of the lab.
What you need
- Go Direct Temperature Probe1
- Vernier Stir Station and stir bar1
- Electrode Support1
- foam cup1 (200-250 mL)
- 400 mL beaker1
- two 50 mL graduated cylinders2
- 0.1 M Hydrochloric acid solution50.0 mL of 1.00 M HCl · teacher
- 0.10 M Sodium hydroxide solution50.0 mL of 1.05 M NaOH · teacher
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 8
Assemble the calorimeter cup
- Place the polystyrene foam cup snugly inside the 400 mL glass beaker.
- Drop one clean magnetic stir bar gently into the bottom of the cup.
- Place the nested cup directly in the centre of the Stir Station platform.
- The foam cup sits flat and does not tip inside the beaker.
- The glass beaker has no cracks or chips.
Careful: If you drop a stir bar forcefully into a glass beaker, you can crack glassware. Slide the stir bar down the side of the foam cup gently.

Step 2 of 8 Teacher does this
Adult measures and adds the acid
- The adult measures exactly 50.0 mL of 1.00 M hydrochloric acid in a 50 mL graduated cylinder.
- Pour the acid carefully into the nested foam cup.
- Students read the cylinder volume from eye level to confirm exactly 50.0 mL.
- The adult wears splash goggles and purple chemical-resistant gloves.
- Spill paper towels are nearby.
- Students stand one step back from the station where the adult pours.
Careful: 1.00 M HCl causes chemical burns to eyes and skin if splashed. Adult pours slowly with cylinder spout close to the cup rim. Never lean over the cup.

Step 3 of 8
Position the temperature probe
- Attach the Electrode Support to the upright rod on the Stir Station.
- Snap the Go Direct Temperature Probe handle securely into the support arm.
- Lower the support so the metal probe tip dips 2 to 3 cm into the acid. Do not touch the stir bar.
- The probe handle is tightly clamped.
- The metal tip does not hit the bottom stir bar.
Careful: If the stir bar spins and hits the probe tip, it can jam or splash acid. Position the probe tip halfway down in the liquid, slightly off-centre.

Step 4 of 8 Teacher does this
Adult measures the sodium hydroxide
- The adult measures 50.0 mL of 1.05 M sodium hydroxide in the second graduated cylinder.
- Place the filled cylinder carefully next to the Stir Station on the lab bench.
- Keep this cylinder still until you are ready for the reaction step.
- The adult wears purple gloves and splash goggles.
- The graduated cylinder is clean and dry before you fill it.
- The base bottle has a cap immediately after you pour.
Careful: Sodium hydroxide solution is corrosive and feels slippery, which can cause drops or spills. Adult holds cylinder firmly with two gloved hands and wipes any exterior drip with paper towel.

Step 5 of 8
Record steady baseline temperature
- Tap Collect in Graphical Analysis.
- Watch the graph for about 10 seconds while the stir bar spins gently.
- Make sure 3 to 4 points plot at the exact same baseline temperature (around 23.5 to 24.0 degrees Celsius).
- The stir bar rotates smoothly on low speed.
- The temperature line is steady and flat.
Careful: If you add the base before the baseline stabilizes, the start temperature becomes inaccurate. Wait until at least 4 consecutive dots plot in a flat horizontal line.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
Versions and what each needs
- Why do mixed liquids warm up?
Chemistry through Inquiry, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe