Experiments › Chemistry and Physical Science

Why do pressure cookers cook faster?

Under Pressure

Grades 7-8Chemistry and Physical Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A stainless steel kitchen pressure cooker with a steaming release valve on a counter

Wonder

How does trapping hot steam cut cooking time by three quarters?

Show the answer

Trapped air particles push harder against their walls as they get hotter. Today you test this gas law to solve a mystery about a faulty cooker.

A stainless steel kitchen pressure cooker on a stove with steam puffing from its lid valve

Introduction

The Case of the Slow Cooker

Customers bought a new kitchen pressure cooker that promised to cook meals in record time. But families complained their dinner stayed raw, and the pressure valve never hissed! A consumer testing team asks you to investigate: was the cooker reaching the right pressure? You will build a model cooker using trapped air, test it across five temperatures, and discover how pressure changes when heat rises.

Driving question: Why does heating trapped air make its pressure climb so fast?

What you will learn

Today you will discover

  • I can explain how temperature changes the pressure of a trapped gas.
  • I can safely collect temperature and pressure data from water baths.
  • I can describe the straight-line shape of a pressure versus temperature graph.
  • I can use my data line to find out if the kitchen appliance worked as advertised.
  • I can name everyday machines that rely on gas pressure and temperature.

Why it matters: Engineers rely on gas pressure laws to design car tires, airplane cabins, rocket engines, and hospital steam sterilizers.

Safety first

Lab Rules for Today

  • Wear splash goggles and lab aprons at all times around water baths.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hot water baths must never exceed 50°C. Water above 50°C can burn skin and pop out stoppers.
  • Keep tablets and electronic sensors at least 30 cm away from all water beakers.
  • Glassware gets heavy and slippery when wet. Always hold beakers with two hands.
  • Never force the stopper or syringe past resistance. Call an adult if fittings feel stuck.
  • Wash your hands fully with soap at the end of class.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • Tablet running Graphical Analysis1
  • Stir Station1
  • Electrode Support1
  • 125 mL Erlenmeyer flask1
  • Two-hole rubber stopper with valve and tubing1
  • 1 L beaker5
  • ice cubes1 bowl of ice and 50 g salt
  • clear solution in a reagent bottle1 thermal jug (hot water up to 50°C) · teacher
  • protective lab gloves1 set per student
Five 1 L beakers showing a temperature progression from salt ice to hot water

Step 1 of 6 Teacher does this

Prepare five water baths

  1. Line up five 1 L beakers on your lab bench and label them 1 to 5.
  2. Bath 1: fill with ice, water, and 3 spoonfuls of salt (below 0°C).
  3. Bath 2: fill with ice and cold water (0°C to 10°C). Bath 3: cool tap water (10°C to 20°C).
  4. Bath 4: warm water (20°C to 35°C). Bath 5: hot water under 50°C added by your teacher.
Stop and check
  • All five beakers are clean and placed safely back from table edges.
  • Students wear goggles and aprons.
  • Teacher dispenses hot water for Bath 5.

Careful: Water hotter than 50°C can cause scalds and build excessive pressure in the flask. Only your teacher adds hot water. Never let bath temperatures exceed 50°C.

A student pairing the pressure sensor and temperature probe to a tablet

Step 2 of 6

Power and connect the sensors

  1. Turn on the Go Direct Gas Pressure Sensor and Go Direct Temperature Probe.
  2. Open Graphical Analysis on your tablet and pair both sensors over Bluetooth.
  3. Make sure both live meters show up on your screen: Pressure and Temperature.
Stop and check
  • Table surface is dry around the tablet.
  • Sensors are charged with green indicator lights.

Careful: Water splashes on the tablet or sensor ports can damage electronics. Keep electronics 30 cm away from all water beakers.

A student twisting a two-hole rubber stopper firmly into a dry 125 mL flask

Step 3 of 6

Assemble the airtight flask

  1. Check that the 125 mL flask neck and rubber stopper are completely dry.
  2. Turn the blue lever in line with the tube to open the stopper valve.
  3. Push and twist the stopper firmly into the flask neck to create an airtight seal.
  4. Now close the valve lever crosswise. Connect the tube to the pressure sensor.
Stop and check
  • Flask glass has no cracks or chips.
  • Stopper and flask rim are wiped bone dry with a paper towel.

Careful: A wet stopper slips out easily. Trapped air leaks during tests. Twist with firm downward pressure. Do not slam the stopper against the glass.

Flask and temperature probe clamped securely inside a 1 L beaker on the Stir Station

Step 4 of 6

Mount the flask and temperature probe

  1. Place Bath 1 on the base of your Stir Station.
  2. Attach the Electrode Support clamp to the metal support rod.
  3. Clamp the flask assembly so the water bath covers its entire bulb.
  4. Slide the temperature probe through the support clamp into the water bath.
Stop and check
  • The Stir Station rests flat and stable.
  • The tube reaches the pressure sensor without tension or bends.

Careful: An un-submerged flask neck chills or warms at different speeds than the water. Lower the clamp until the flask bulb is deep in the water. Do not hit the bottom.

Student tapping Keep on the tablet after recording stable readings from the ice salt bath

Step 5 of 6

Record Bath 1 (Ice and Salt)

  1. Tap Collect on the tablet to begin data collection.
  2. Wait at least 2 full minutes for the air inside the flask to match the cold water.
  3. Watch the live meters. Tap Keep when both temperature and pressure no longer drop.
  4. A single point appears in your data table and on the graph near 267 K and 92 kPa.
Stop and check
  • Flask is submerged in the ice and salt bath.
  • The timer or clock is ready to count 2 minutes.

Careful: If you tap Keep too early, you get a pressure reading from room air rather than the chilled bath. Be patient! Wait a full 2 to 3 minutes until both meter numbers hold steady.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
  • Related Class 11, Physics, chapter 3: Thermal Properties of Matter
  • Direct Class 11, Physics, chapter 5: Kinetic Theory
ICSE (CISCE)
  • Related Class 9, Chemistry, chapter 7: Study of Gas Laws
IB Diploma
  • Related Level DP, Physics, chapter 6: B.3 Gas Laws
  • Direct Level DP, Chemistry, chapter Structure 1.5: Ideal gases

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.