Experiments › Chemistry

Why do reactions stop halfway?

Equilibrium Constant

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A playground seesaw resting in perfect horizontal balance on a sunny day

Wonder

Can two opposing forces settle into a perfect, steady balance?

Show the answer

When forward and backward changes happen at the exact same speed, everything stays in balance. Scientists call this chemical equilibrium, and today you will measure it.

A colourful playground seesaw resting completely level and balanced on its fulcrum in a sunny outdoor park

Introduction

Can Reactions Balance Like a Seesaw?

When you bake a cake, you cannot turn it back into raw flour and eggs. That reaction only goes one way! But in chemistry, many reactions are two-way streets. Reactants combine to form products, and products break apart back into reactants. When both directions happen at the exact same speed, the reaction reaches a balance called chemical equilibrium. Today, you will mix two pale solutions to create a ruby-red compound, measure its depth of color with a light sensor, and uncover the secret balance number.

Driving question: Can two chemicals react and settle into a predictable balance point?

What you will learn

Today you will find out

  • I can explain what chemical equilibrium means in a reaction.
  • I can relate the depth of red color to the amount of product formed.
  • I can calibrate and use a colorimeter correctly with clean cuvettes.
  • I can show that the reaction settles at a predictable balance point.
  • I can describe real-world examples of reversible reactions and chemical balance.

Why it matters: Industrial factories use equilibrium to manufacture fertilizers and medicines efficiently without wasting starting materials.

Safety first

Laboratory Safety Rules

  • Wear chemical splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Iron solutions contain 1.0 M nitric acid: this is corrosive and can cause skin burns.
  • Potassium thiocyanate causes eye and skin irritation. Avoid all skin contact.
  • If any liquid touches your skin, rinse immediately with cold tap water for 15 minutes.
  • Keep all test tubes in racks. Never pipette liquids by mouth; use pipette pumps only.
  • Never pour solutions down the regular drain without teacher direction.

What you need

  • Go Direct Colorimeter1 per group
  • Plastic cuvette (4 clear sides)1 per group
  • Go Direct Temperature Probe1 per group
  • Test tubes and rack5 large tubes and 1 rack
  • 0.0020 M Fe(NO3)3 in 1.0 M HNO330 mL in 100 mL beaker · teacher
  • 0.0020 M KSCN solution25 mL in 100 mL beaker
  • Distilled water wash bottle25 mL in 100 mL beaker
  • Pre-mixed Standard Red Solution20 mL in labeled test tube · teacher
  • measuring pipetFour 10 mL pipettes with bulbs
  • Lint-free tissue box1 box
  • glass stirring rod1
Pipetting 5 mL of pale yellow iron solution into four test tubes

Step 1 of 6 Teacher does this

Label your tubes and get iron solution

  1. Label four large test tubes 1, 2, 3, and 4. Place them in your rack.
  2. An adult dispenses 30 mL of pale yellow iron nitrate solution into a 100 mL beaker.
  3. Use a clean 10 mL pipette and pump. Add exactly 5.0 mL of iron solution to each tube.
  4. Wipe any accidental drips immediately with a damp towel.
Stop and check
  • Everyone wears splash goggles and gloves.
  • The adult pours the acid-based iron stock solution.
  • Pipette bulb is attached securely; never use your mouth.

Careful: Nitric acid causes skin burns and damages clothes. Splashes cause eye damage. Work slowly at eye level. Keep beaker flat on the bench. Notify adult of any drip.

Adding drops of clear liquid to tubes causing red color formation

Step 2 of 6

Add thiocyanate and water to each tube

  1. Use a dedicated clean pipette for clear thiocyanate (KSCN) solution.
  2. Add 2.0 mL KSCN to Tube 1, 3.0 mL to Tube 2, 4.0 mL to Tube 3, and 5.0 mL to Tube 4.
  3. Use another clean pipette for distilled water: add 3.0 mL to Tube 1, 2.0 mL to Tube 2, 1.0 mL to Tube 3, and 0 mL to Tube 4.
  4. Every tube now has a total volume of exactly 10.0 mL.
Stop and check
  • Use separate pipettes for thiocyanate and distilled water.
  • Check your recipe table before you release liquid into each tube.

Careful: If you mix up pipettes, you cross-contaminate stock beakers and ruin the concentration ladder. Keep pipettes inside their labeled beakers.

Measuring temperature of the red solution with Go Direct Temperature Probe

Step 3 of 6

Mix thoroughly and measure temperature

  1. Stir each tube with a clean glass rod. Rinse the rod between tubes. Dry the rod.
  2. Place the metal tip of the Go Direct Temperature Probe into Tube 1.
  3. Wait 10 seconds until the reading is steady. Record the solution temperature in your notebook.
  4. Rinse the probe tip with distilled water. Wipe the tip dry.
Stop and check
  • Stir gently so you do not crack the glass tube bottom.
  • Wipe the glass rod with tissue between tubes so you do not carry liquid over.

Careful: Unmixed solutions have dense layers that give false readings in the colorimeter. Stir until the color is completely uniform from top to bottom.

Pressing the CAL button on Go Direct Colorimeter with cuvette inserted

Step 4 of 6

Calibrate the Colorimeter with a blank

  1. Fill a clean cuvette three-quarters full with 0.0020 M iron nitrate solution (this is your blank).
  2. Handle the cuvette only by the ribbed top edges. Wipe the clear sides with a lint-free tissue.
  3. Place the cuvette into the Colorimeter slot so clear sides align with the light beam. Close the lid.
  4. Press the CAL button on the Colorimeter. When the indicator LED no longer flashes, calibration is complete.
Stop and check
  • The cuvette is three-quarters full and does not overflow.
  • The outside of the cuvette is completely dry and free of fingerprints.

Careful: Fingerprints on the clear plastic block blue light and make all measurements inaccurate. Touch only the ribbed upper edges. Wipe both clear optical faces with lint-free tissue.

Student placing cuvette into colorimeter while tablet plots absorbance points

Step 5 of 6

Measure Tubes 1 through 4

  1. Empty the blank into your acid waste container. Tap Collect in Graphical Analysis.
  2. Rinse the cuvette twice with 1 mL portions of Tube 1. Fill it three-quarters full.
  3. Wipe the sides of the cuvette. Put it into the Colorimeter. Close the lid. Wait for the reading to stabilize.
  4. Tap Keep. Repeat this process for Tube 2, Tube 3, and Tube 4.
Stop and check
  • Always rinse the cuvette with a small splash of the new solution before you measure.
  • Keep all liquids away from the tablet and sensor electronics.

Careful: Drops of previous solution dilute the new solution and cause a false absorbance reading. Do two quick rinses with ~1 mL of liquid from the next tube before you fill the cuvette.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Chemistry, chapter 6: Equilibrium
Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 8: Equilibria

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.