Experiments › Chemistry
Why do scrapes fizz and foam?
Rxn Rate
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does first-aid liquid bubble and foam on a scrape?
Show the answer
Tiny helper particles in blood quickly turn the liquid into oxygen gas. Scientists call this reaction rate, and today you will measure it.

Introduction
How Fast Does Fizz Build Up?
Rust takes months to form on an iron nail, while a firework explodes in a second. What controls how fast chemical reactions happen? Hydrogen peroxide breaks down on its own over months into water and oxygen gas. But add a tiny bit of catalyst, and oxygen gas bursts forth in seconds! In this experiment, you trap that oxygen gas in a sealed flask and use a digital sensor to clock the speed of the reaction.
Driving question: Why do some chemical reactions happen in a flash while others take years?
What you will learn
Today you will discover
- I can explain how a catalyst speeds up a reaction.
- I can measure gas pressure rise as oxygen forms.
- I can compare reaction speeds under different conditions.
- I can connect gas tubing and vent pressure safely.
- I can describe why controlling reaction speed matters in industry and daily life.
Why it matters: Rocket engines, car exhaust converters, and bread-baking all depend on controlling the exact speed of chemical reactions.
Safety first
Laboratory Safety Rules
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hydrogen peroxide can irritate skin and eyes. Flush immediately with water if spilled.
- Never let the flask pressure exceed 130 kPa. If it reaches 130 kPa, open the valve or loosen the stopper immediately.
- Handle glass flasks and cylinders gently to prevent breaks.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct Gas Pressure Sensor1
- Go Direct Temperature Probe1
- Vernier Stir Station and stir bar1
- 125 mL Erlenmeyer flask and clamp1 set
- Two-hole rubber stopper with valve and tubing1 set
- 10 mL graduated cylinders2
- 50 mL graduated cylinder1
- 3% hydrogen peroxide, H2O2, solution40 mL
- 0.5 M potassium iodide, KI, solution30 mL
- Distilled water wash bottle200 mL
- Cold water bath1 tub
- Tablet running Graphical Analysis1

Step 1 of 8
Chill cold liquids for Trial 4
- Pour 15 mL of 3% hydrogen peroxide into a small container.
- Pour 10 mL of 0.5 M potassium iodide and 50 mL of distilled water into separate tubes.
- Place all three containers into the cold ice water bath so they chill for later.
- Wear your safety goggles and gloves.
- Check that your ice bath is stable and will not tip over.
Careful: Hydrogen peroxide can splash onto skin or clothes. Pour slowly. Wipe any drips immediately with a wet paper towel.

Step 2 of 8
Assemble the Stir Station and flask
- Place the magnetic stir bar inside the clean 125 mL Erlenmeyer flask.
- Clamp the flask neck to the support rod centered on the Stir Station platform with the utility clamp.
- Turn the speed knob to choose a smooth, moderate speed. Then turn it off.
- The Stir Station cord is kept away from water sinks.
- The flask is centered directly over the magnetic drive.
Careful: If you clamp the glass neck too tightly, you can crack the flask. Tighten the clamp fingers gently until snug. Do not overtighten.

Step 3 of 8
Connect the gas tubing and sensor
- Attach the clear tube to one rubber stopper stem with a half-turn twist.
- Connect the opposite end of the tube to the Gas Pressure Sensor port.
- Rest the sensor flat on the table beside the Stir Station.
- The tube has no kinks or sharp bends.
- Luer-lock twist fittings are snug.
- Make sure the blue stopcock valve on the stopper is closed.
Careful: Loose fittings allow gas to escape and cause flat, zero-slope data. Twist each Luer-lock connector half a turn until firmly locked.

Step 4 of 8
Measure reactants for Trial 1
- Add 45 mL distilled water using the 50 mL cylinder and 10 mL 3% hydrogen peroxide using a clean 10 mL cylinder into the flask.
- Insert the Go Direct Temperature Probe into the flask to measure and record the initial temperature, then remove it.
- Measure 5 mL of 0.5 M potassium iodide in a second cylinder.
- Graduated cylinders are clean and labeled.
- Make sure the temperature probe is clean before you insert it.
- Insert the temperature probe into the flask, measure and record the liquid temperature, then remove the probe.
Careful: If you mix potassium iodide before you seal the flask, initial oxygen gas escapes. Keep the measured potassium iodide in its cylinder until you are ready to seal.

Step 5 of 8
Add catalyst and seal the flask
- Quickly pour the 5 mL of potassium iodide solution into the flask.
- Immediately press the rubber stopper firmly into the flask neck to create an airtight seal.
- Switch on the Stir Station to your preset speed. Tap Collect on the tablet.
- The rubber stopper is pushed down firmly.
- The blue valve on the stopper is tightly closed.
- The partner is ready to tap Collect instantly.
Careful: If you delay the stopper, early oxygen escapes and causes a slow start. One partner pours while the second partner pushes the stopper firmly in.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 12, Chemistry, chapter 3: Chemical Kinetics
- Related Level AS & A Level, Chemistry, chapter 6: Enthalpy changes
- Direct Level AS & A Level, Chemistry, chapter 9: Rates of reaction
- Direct Level AS & A Level, Chemistry, chapter 22: Reaction kinetics
- Direct Level AS & A Level, Chemistry, chapter P1: Practical skills 1
- Direct Level AS & A Level, Chemistry, chapter P2: Practical skills 2
- Direct Level DP, Chemistry, chapter Reactivity 2.2: How fast? The rate of chemical change
Versions and what each needs
- Why do scrapes fizz and foam?
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.