Experiments › Chemistry

Why do sealed bottles hiss when warm?

Vapor

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

A plastic bottle warming in the sun with vapour arrows pushing outward

Wonder

Why does a bottle of hand sanitiser hiss when opened on a hot day?

Show the answer

Alcohol inside the bottle turns into an invisible gas. Trapped gas particles bounce against the plastic walls, creating pressure. Today, you will measure this hidden push.

A sealed clear plastic bottle sitting on a sunny wooden windowsill

Introduction

Why Does a Sealed Bottle Push Harder When Warmed?

When you leave rubbing alcohol or perfume open, it vanishes into thin air. Where does it go? The liquid evaporates into invisible gas particles. If the bottle has a tight cap on, the evaporating gas gets trapped inside. As the liquid warms up, its particles zoom around faster and crash against the walls, pushing outwards. Scientists call this push vapor pressure. In this experiment, you will warm a sealed liquid and measure how hard its vapour pushes.

Driving question: Why does liquid inside a sealed bottle push harder against the walls when warmed?

What you will learn

Today you will discover

  • I can explain how evaporating liquid creates vapor pressure.
  • I can record pressure and temperature changes using digital sensors.
  • I can show that heating a liquid increases its vapor pressure.
  • I can name real-life systems where vapour pressure matters.
  • I can follow safety steps when working with warm glassware and alcohol.

Why it matters: Understanding vapour pressure helps engineers build pressure cookers, prevents car fuel tanks from leaking, and explains how clouds form in the sky.

Safety first

Lab Rules for Today

  • Wear splash goggles, protective gloves, and a lab apron throughout the activity.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Denatured ethanol is flammable and poisonous. Keep it away from all heat sources and never inhale its fumes.
  • Only your teacher dispenses and injects ethanol with the syringe.
  • Never heat the water bath above 40°C. High pressure can pop the stopper out of the flask.
  • Open the stopper valve before you remove the stopper to release gas pressure gently.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • Vernier Stir Station and stir bar1
  • 125 mL Erlenmeyer flask1
  • Two-hole rubber stopper with valve and tubing1 set
  • 1 L beaker1
  • 400 mL beaker1
  • plastic syringe1 (20 mL) · teacher
  • commercial liquids5 mL denatured ethanol · teacher
  • plastic spoon1 spoon or dipper
  • Splash goggles and nitrile gloves1 set per person
An adult heating water in a 400 mL beaker on a laboratory hot plate

Step 1 of 10 Teacher does this

Prepare the warm water source

  1. Your teacher warms about 200 mL of water in a 400 mL beaker with a hot plate or hot tap.
  2. Keep the water comfortably warm around 50°C. Never let it boil.
  3. Place the warm beaker safely away from table edges.
Stop and check
  • Hot plate cord is safely tucked in.
  • Hot plate is well away from any alcohol bottles.
  • The adult wears heat-resistant gloves.

Careful: Hot water splashes can cause burns. Hot surfaces can ignite flammable vapours. Only the adult handles the hot plate. Keep alcohol bottles far away from heat sources.

1 L beaker with water and stir bar resting on the Stir Station

Step 2 of 10

Set up the room-temperature water bath

  1. Fill the 1 L beaker about halfway with room-temperature tap water.
  2. Place the magnetic stir bar inside the beaker.
  3. Set the 1 L beaker on top of the Stir Station platform.
Stop and check
  • Stir Station is turned off while setting up.
  • Beaker is placed squarely in the centre of the stir platform.

Careful: Beaker can tip if placed off-centre. Centre the 1 L beaker on the platform and pour water steadily.

Connecting clear tubing from rubber stopper to the pressure sensor

Step 3 of 10

Connect the sensors and tubing

  1. Connect the clear plastic tube to the rubber stopper and the Gas Pressure Sensor.
  2. Twist the rubber stopper snugly into the dry 125 mL Erlenmeyer flask.
  3. Open the two-way valve on the stopper so air can move freely.
Stop and check
  • Flask is dry inside.
  • The tube has no kinks or sharp bends.
  • Valve lever is set to OPEN.
  • Threaded fittings are turned half a turn to lock them airtight.

Careful: Loose fittings cause gas to leak. This causes pressure readings to drop. Twist fittings firmly until hand-tight. Do not over-tighten plastic threads.

Temperature probe and open flask resting on lab table with tablet display

Step 4 of 10

Record initial air conditions

  1. Place the Temperature Probe on the bench near the flask.
  2. Wait until the pressure and temperature readings on the tablet do not change.
  3. Record this initial air pressure and room temperature in your notebook as Initial.
Stop and check
  • Flask valve is open to room air.
  • Readings on the tablet are steady.

Careful: If you touch the probe tip with warm fingers, you alter the room temperature reading. Rest the probe tip on the bench surface. Do not hold it.

Flask held submerged in water bath with temperature probe beside it

Step 5 of 10

Submerge the flask and close the valve

  1. Lower the Erlenmeyer flask into the 1 L room-temperature water bath.
  2. Hold or clamp the flask so water reaches just below the bottom of the stopper.
  3. Place the Temperature Probe into the water bath.
  4. After 30 seconds, close the valve on the stopper tightly.
Stop and check
  • Water level does not spill over the top of the 1 L beaker.
  • The stopper stays above water level so water does not enter the flask.
  • Valve is closed after 30 seconds.

Careful: Water can enter the flask and spoil the test if you submerge the stopper. Keep the water level 1 cm below the stopper line at all times.

5 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 11, Chemistry, chapter 6: Equilibrium
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 5: States of matter

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.