Why do sliced apples turn brown?
Enzyme Kinetics and Tyrosinase Activity
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a freshly sliced apple or potato turn brown after just a few minutes?
Show the answer
Damaged plant cells unleash an enzyme called tyrosinase. It turns clear plant chemicals into protective dark pigments. Today you will measure how fast this reaction happens!

Introduction
The Browning Mystery
When you slice an apple or drop a potato, the bruised spot turns brown. This is not dirt. It is a defence reaction made by living cells! Damaged cells release an enzyme named tyrosinase. In the presence of oxygen, tyrosinase turns clear helper molecules into orange and brown pigments. Today, we extract this enzyme from a potato and measure how fast it works using a light sensor.
Driving question: Why do freshly cut apples and potatoes turn brown, and how fast does this chemical reaction happen?
What you will learn
Today you will discover
- I can explain what an enzyme does in living things.
- I can explain why bruised or sliced fruit turns brown.
- I can track how fast colour forms on a live graph.
- I can find the speed of an enzyme reaction from a graph slope.
- I can handle cuvettes and micropipettes cleanly and safely.
Why it matters: Enzymes run almost every chemical process in your body, from digesting dinner to copying DNA. Food scientists study plant enzymes to keep fresh fruit looking delicious.
Safety first
Lab Rules for Today
- Wear chemical splash goggles and protective gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- DOPA solution can irritate eyes and skin. Avoid contact and never touch your face.
- Keep all liquids at least 30 cm away from the spectrophotometer and tablet.
- Hold cuvettes only by the ribbed sides near the top edge.
- Wash your hands fully with soap and water after you clean up.
What you need
- Go Direct SpectroVis Plus Spectrophotometer1 · teacher
- Plastic cuvette (4 clear sides)2 cuvettes with lids
- Tablet running Graphical Analysis1
- 15 mL centrifuge tube5 mL 0.1 M phosphate buffer (pH 6.8)
- 15 mL centrifuge tube5 mL 20 mM DOPA solution
- cloudy biological liquid1 mL potato enzyme extract in ice cup
- micropipette100–1000 µL and 20–200 µL micropipettes with tips
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 set per person

Step 1 of 5
Prepare the blank cuvette
- Use the 1000 µL micropipette. Transfer two 1000 µL aliquots (2.0 mL, 2000 µL total) of phosphate buffer into a clean cuvette.
- Wipe the clear sides of the cuvette gently with a lint-free tissue.
- Tap the cuvette gently on the table to remove air bubbles that stick to the sides.
- Wear splash goggles and gloves.
- Micropipette set to 1000 µL (pipette twice for 2.0 mL).
- Cuvette handled only by top edges.
- Handle the cuvette only by the ribbed top edges.
Careful: Fingerprints or dust on the cuvette will scatter light and give wrong numbers. Wipe the clear optical faces with a lint-free wipe before you test.

Step 2 of 5 Teacher does this
Connect sensor and calibrate blank
- Switch on the Go Direct SpectroVis Plus. Open Spectral Analysis on the tablet.
- Place the buffer cuvette into the sensor slot with clear sides in the light path.
- Select Calibrate in the app. Wait for the lamp warm-up countdown. Tap Finish Calibration.
- Connect the SpectroVis Plus with Bluetooth or USB.
- Clear cuvette sides face the light beam arrows.
- Work area is dry.
- Pure buffer will be calibrated to zero absorbance.
Careful: If you calibrate with dirty buffer, you get false absorbance readings for all later steps. Make sure the cuvette contains only pure buffer before you tap Finish Calibration.

Step 3 of 5 Teacher does this
Find the peak wavelength for dopachrome
- Transfer 2.0 mL of 20 mM DOPA. Use a 20–200 µL micropipette to add 100 µL of potato enzyme.
- Cap the cuvette, gently invert it twice to mix, and let it stand for 2 minutes until orange.
- Place the orange cuvette into the sensor. Select the peak wavelength near 475 nm. Tap Done.
- Enzyme extract was kept cold in ice until right now.
- Make sure the cuvette cap is tight before you invert the cuvette.
- An adult oversees as you use the pipette.
- Empty the blank cuvette before you add solutions.
Careful: DOPA or enzyme can spill if the cap is loose. If you invert too vigorously, foam bubbles form. Press cap tightly and invert gently twice. Wipe off any drips.

Step 4 of 5
Mix enzyme and start collection quickly
- Pipette 1000 µL of 20 mM DOPA solution twice (2.0 mL total) into the clean dry cuvette.
- Pipette 100 µL of potato enzyme extract into the cuvette.
- Cap firmly, invert twice, insert cuvette into SpectroVis Plus, and tap Start to collect for 200 seconds.
- Cuvette is clean and dry.
- Both team members ready: one adds enzyme, one taps Start.
- Enzyme tip is fresh and seated firmly.
Careful: The reaction starts the instant enzyme touches DOPA. If you delay, you miss the fastest part of the reaction. Cap, invert twice, insert cuvette, and tap Start without delay.

Step 5 of 5
Find the reaction rate using linear fit
- Click on the initial linear portion (the first 0 to 60 seconds). Drag across this section.
- Select Linear Fit from the graph tools menu.
- Record the slope (m) from the pop-up box as reaction rate in Δ abs/s.
- The full 200-second run is complete.
- The curve is smooth without spikes.
- Only the first 60 seconds are highlighted.
- Make sure data collection finishes at 200 seconds before you look at your graph.
Careful: If you highlight the whole curve, the slope is too low because the reaction slows down later. Select only the first 60 seconds where the line is straightest.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level AS & A Level, Biology, chapter 16: Inheritance
Versions and what each needs
- Why do sliced apples turn brown?
Investigating Biology, 60 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.