Experiments › Physical Science

Why do some mixes get hot or cold?

Endothermic and Exothermic Reactions

Grades 7-8Physical Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The complete lab is below, free, in View mode.

The complete lab, free

Free complete lab for CBSE Class 10 Science Alpha: being verified by teachers

Every screen of the lab as it appears in the Stemious app's View mode: all 10 steps, the data, observations, conclusions and quiz. Quiz answers stay in the app, so the quiz still works in class. To run it with the sensors and save each student's data, use the app.

An instant cold pack pouch and an air-activated hand warmer packet side by side

Wonder

Can mixing two room-temperature liquids make something freeze without a fridge?

Show the answer

Some mixtures soak up heat and turn icy cold, while others release heat and warm up. Scientists call these endothermic and exothermic reactions, and today you will measure both.

An instant cold pack pouch with droplets of condensation resting beside an activated pocket hand warmer on a wooden table

Introduction

The Mystery of Chemical Heat

When you strike a match, heat pours out into the air. But when you snap an emergency cold pack, it instantly turns icy cold. Neither one was plugged into electricity. Where does all that heat come from, and where does it vanish to? In this lab, you mix two pairs of chemicals and watch live graphs reveal the secret energy changes inside molecules.

Driving question: Why do some chemical reactions make things cold while others make them hot?

What you will learn

Today you will find out

  • I can explain the difference between endothermic and exothermic reactions.
  • I can set up a temperature probe and record temperature over time.
  • I can find the initial and peak temperatures on a graph to calculate the temperature change.
  • I can list visible signs that prove a chemical change happened.
  • I can name everyday examples of reactions that absorb or give off heat.

Why it matters: Engineers design self-heating meals, instant cold packs for injured athletes and energy-efficient engines using these exact principles.

An athlete holding an instant cold pack against an injured ankle

Try These

Instant Ice for Injured Athletes

  • Sports trainers squeeze a pouch inside an ice pack to mix water with ammonium nitrate or urea.
  • The pack drops to near freezing in seconds without ever touching a refrigerator.
A flameless ration heater bag steaming hot food outdoors

Try These

Flameless Ration Heaters

  • Soldiers and campers heat meals without fire using a small pouch containing magnesium and iron powder.
  • Adding a splash of water triggers a fast exothermic reaction that boils water in minutes.
Rocket engine test firing with intense flame exhaust

Try These

Spacecraft Heat Shields and Rocket Fuel

  • Rocket engines release enormous energy by combining hydrogen and oxygen into water vapor.
  • Spacecraft engineers calculate exact thermal outputs to ensure rocket nozzles survive the heat.

Warm-up question

When a campfire burns, what happens to the surrounding air?

  1. The air gets warmer because the wood releases thermal energy
  2. The air gets colder because the fire destroys heat
  3. The temperature stays exactly the same
  4. The air freezes because smoke blocks the sunlight

Warm-up question

What happens to the temperature of a liquid if a reaction inside it absorbs heat from the liquid?

  1. The temperature of the liquid decreases
  2. The temperature of the liquid increases
  3. The temperature cannot change once mixed
  4. The liquid boils instantly into steam
Diagram showing heat arrows exiting from a reaction beaker

Key idea

Exothermic: Heat exits into the surroundings

  • In an exothermic reaction, chemicals release thermal energy.
  • The word prefix 'exo-' means exit or outside.
  • This extra thermal energy warms up the surrounding liquid and air.
  • A thermometer in the mixture shows a rising temperature line.

Everyday example: A burning candle, a wood campfire, or a pocket hand warmer all release heat.

Diagram showing heat arrows entering into a reaction beaker

Key idea

Endothermic: Heat enters into the reaction

  • In an endothermic reaction, chemicals absorb thermal energy.
  • The word prefix 'endo-' means enter or inside.
  • The reaction pulls heat away from the surrounding liquid.
  • Because heat leaves the liquid, a thermometer shows a falling temperature line.

Everyday example: Squeezing an instant cold pack causes chemicals to soak up heat, turning the pack icy cold.

Safety first

Laboratory Safety Rules

  • Wear splash goggles, protective gloves and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hydrochloric acid is corrosive and can damage skin and eyes. Only your teacher pours 1.0 M HCl.
  • Magnesium produces hydrogen gas and warm acid mist. Do not lean over the cup or breathe vapors.
  • No open flames allowed anywhere in the laboratory during this experiment.
  • Look for the ADULT NEEDED badge. Only an adult handles those steps.
  • Wash your hands fully with soap and water after you clean up.

What you need

  • Go Direct Temperature Probe1
  • Tablet running Graphical Analysis1
  • foam cup2
  • 250 mL beaker1
  • ring stand with clamp1 set
  • 50 mL graduated cylinder1
  • glass stirring rod1
  • Digital balance (0.01 g precision)1 shared
  • citric acid solution30 mL
  • white chemical powder10.0 g
  • 0.1 M Hydrochloric acid solution30 mL
  • metal ribbon strip1 strip (0.10 g)
  • safety goggles1 per person
Foam cup placed inside a 250 mL beaker on a lab bench

Step 1 of 10

Assemble your calorimeter cup

  1. Place one foam cup securely inside the 250 mL glass beaker.
  2. The heavy glass beaker keeps the lightweight foam cup upright.
  3. The foam walls trap heat inside so the sensor can measure it accurately.
Stop and check
  • Foam cup has no cracks or holes.
  • Glass beaker is clean and dry.
  • Beaker sits flat on the table.

Careful: An unsupported foam cup can tip over and spill liquid across the bench. Always keep the foam cup inside the heavy glass beaker.

Student pouring citric acid from graduated cylinder into foam cup

Step 2 of 10

Measure 30 mL of citric acid

  1. Use the 50 mL graduated cylinder to measure exactly 30 mL of citric acid solution.
  2. Read the liquid level at eye level with the bottom of the curved meniscus.
  3. Pour the 30 mL of citric acid into the foam cup.
Stop and check
  • Splash goggles are on your eyes.
  • The graduated cylinder is clean and rests on the table.

Careful: Citric acid can irritate eyes or skin if splashed. Pour slowly. Wipe any drips on the outside of the cylinder immediately.

Temperature probe clamped in ring stand dipping into cup

Step 3 of 10

Clamp probe in the solution

  1. Attach the utility clamp to the ring stand and grip the Go Direct Temperature Probe handle.
  2. Lower the probe so the stainless steel tip dips 2 cm into the citric acid.
  3. Wait at least 45 seconds for the probe to equilibrate to the liquid temperature before you collect data.
Stop and check
  • The ring stand base rests flat on the bench.
  • Clamp thumbscrew is firmly tightened on the stand rod.
  • Make sure the probe tip does not touch the bottom or sides of the cup.

Careful: The clamp can slip and drop the probe. This can puncture the foam cup. Tighten the clamp wing nut securely before letting go of the probe.

Student spooning baking soda onto a digital balance

Step 4 of 10

Weigh 10.0 g of baking soda

  1. Place a square sheet of weighing paper on the digital balance.
  2. Press Tare or Zero so the balance reads 0.00 g.
  3. Carefully add baking soda with a spoon until the balance reads exactly 10.00 g.
Stop and check
  • The balance reads 0.00 g after you tare it.
  • Weighing paper is dry and centred on the balance pan.
  • Fold the paper gently into a V-shape crease so it pours easily.

Careful: If you spill powder on the balance mechanism, you can damage delicate sensors. Add small scoops slowly. Do not overload the balance pan.

Graphical Analysis app settings dialog showing 1 sample per second for 250 seconds

Set up the sensor

Configure data collection settings

Sensor
Go Direct Temperature Probe
App
Vernier Graphical Analysis
Why this mode
Time-based mode tracks temperature continuously every second so you can see the exact moment the reaction begins and ends.
Duration
250 seconds
Before you start
Ensure probe is submerged in solution for at least 45 seconds before starting collection.
Graphic showing question marks over a temperature graph curve

Predict

When you stir baking soda into citric acid, what will happen to the temperature?

Make your prediction based on what you know about chemical reactions. Your live graph will reveal the truth in moments.

  • The temperature will drop noticeably (colder)
  • The temperature will rise sharply (hotter)
  • The temperature will stay exactly the same
  • The liquid will freeze solid instantly into ice

Students record a prediction in the app before collecting data.

Student pouring baking soda into cup at 10 seconds mark

Step 5 of 10

Record baseline, then add baking soda

  1. Tap Collect to start data collection.
  2. Watch the graph for 10 seconds to establish a flat baseline line.
  3. At exactly 10 seconds, quickly slide all 10.0 g of baking soda into the cup.
Stop and check
  • Probe has been in the liquid for at least 45 seconds.
  • Baking soda is folded on paper ready to pour.
  • One teammate watches the tablet clock.
  • Wait until the probe has rested in the citric acid for 45 seconds.

Careful: If you pour before 10 seconds, you ruin the baseline needed to calculate temperature change. Watch the time counter on the tablet screen and pour right at 10 seconds.

Stirring fizzing mixture in foam cup while graph plunges downwards

Step 6 of 10

Stir gently and observe the cold drop

  1. Use the glass stirring rod to gently and continuously stir the mixture.
  2. Watch the tablet: the temperature curve plunges steeply downward.
  3. Stir gently until data collection automatically stops at 250 seconds.
Stop and check
  • Stir gently. Do not hit the probe or the foam cup.
  • Keep hands clear of foam that fizzes.

Careful: If you stir hard, acid foam can splash out of the cup or crack the cup. Stir in smooth, slow circles with the glass rod.

Student rinsing the stainless steel temperature probe with a wash bottle

Step 7 of 10

Record Part I data and rinse cup

  1. Find the initial temperature at 10 seconds and the lowest minimum temperature.
  2. Record both numbers in your lab notebook.
  3. Empty the liquid down the sink while water runs. Rinse the cup. Wipe the probe tip.
Stop and check
  • The sink tap runs before you pour the spent citric acid mix.
  • Rinse the probe tip fully with distilled water.

Careful: Residual citric acid on the probe will contaminate Part II. Rinse the metal shaft with distilled water and dry with a paper towel.

Teacher in purple gloves pouring 1.0 M HCl into the foam cup

Step 8 of 10 Teacher does this

Adult adds hydrochloric acid for Part II

  1. Your teacher measures and pours 30 mL of 1.0 M hydrochloric acid into the cup.
  2. Re-clamp the temperature probe so the tip dips 2 cm into the acid.
  3. Wait 45 seconds for the probe to reach equilibrium with the liquid.
Stop and check
  • The teacher wears purple gloves and splash goggles.
  • Students take one step back from the acid bottle.
  • Room ventilation or exhaust fan is turned on.
  • Place a fresh dry foam cup inside the 250 mL beaker.

Careful: 1.0 M Hydrochloric acid causes severe chemical burns on contact with skin or eyes. Only the teacher pours the hydrochloric acid. If splashed, flush immediately with water for 15 minutes.

Student dropping magnesium ribbon into acid solution with steam rising

Step 9 of 10 Teacher does this

Start data, then add magnesium ribbon

  1. Tap Collect in Graphical Analysis to start a new data run.
  2. Wait 20 seconds to establish a solid baseline temperature line.
  3. At 20 seconds, drop the magnesium ribbon into the acid and stir gently with the glass rod.
Stop and check
  • Goggles are tightly sealed on your eyes.
  • Magnesium ribbon strip is dry and uncoiled slightly.
  • Keep face at least 40 cm away from the cup mouth.
  • Receive one 0.10 g strip of magnesium ribbon from your teacher.

Careful: The reaction produces flammable hydrogen gas and acid mist. If you inhale vapors, you irritate your lungs. Do not lean over the cup. Stir gently. Do not inhale mist that rises.

Tablet graph showing red temperature curve climbing sharply from 22.7 °C to 35.1 °C

Step 10 of 10

Track the heat climb to maximum

  1. Stir gently as the magnesium fizzes vigorously and disappears.
  2. Watch the graph climb rapidly upward as thermal energy pours out.
  3. Collect data until data collection stops at 250 seconds.
Stop and check
  • Stir gently. Do not splash the liquid.
  • Keep your head back from the reaction vapors.

Careful: The cup becomes warm to the touch. If you drop the probe, acid can splatter. Touch only the glass stirring rod. Keep the probe firmly clamped.

Read your graph

Comparing Endothermic and Exothermic Curves

  • Part I drops from 22.7 °C down to 2.3 °C: a drop of 20.4 °C (Endothermic).
  • Part II climbs from 22.7 °C up to 35.1 °C: a rise of 12.4 °C (Exothermic).
  • Both reactions show a steady flat baseline before the solid reactant is added.

Troubleshoot

Solving Common Lab Issues

Temperature probe reading does not change when placed in liquid.
Wait at least 45 seconds for thermal equilibrium. If still frozen, check Bluetooth connection in Graphical Analysis.
Part I temperature barely dropped (less than 5 °C drop).
Make sure that you add all 10.0 g of baking soda and stir continuously. Unstirred powder settles to the bottom.
Part II temperature rose very slowly or ribbon did not dissolve.
Make sure that the magnesium ribbon was clean and submerged. Stir gently to keep fresh acid in contact with the metal.
Graph line looks jagged or full of random spikes.
Do not let the probe bump against the stirring rod or cup walls while stirring.
Student rinsing glassware at lab sink while teacher disposes of acid waste

Clean up

Clean up like a scientist

  1. Your teacher neutralizes and disposes of the hydrochloric acid mixture from Part II.
  2. Rinse the foam cups and graduated cylinders fully with tap water. Let them dry.
  3. Rinse the stainless steel probe shaft with distilled water and dry with a soft tissue.
  4. Turn off the Go Direct Temperature Probe. Return it to its storage case.
  5. Wipe your lab bench clean. Wash your hands fully with soap and water.

Disposal: Part I (citric acid and baking soda) is harmless sodium citrate. Flush it down the sink with water. Give Part II (HCl and magnesium) to your teacher for neutralization before disposal.

Observation

When baking soda was added to citric acid, the temperature dropped sharply by about 20 °C.

In the app, students agree or disagree from their own data.

Observation

In both reactions, vigorous fizzing and gas bubbles appeared immediately after mixing.

In the app, students agree or disagree from their own data.

Observation

When magnesium was dropped into hydrochloric acid, the temperature fell below room temperature.

In the app, students agree or disagree from their own data.

Observation

By the end of Part II, the shiny silver magnesium strip had completely dissolved and disappeared.

In the app, students agree or disagree from their own data.

Observation

The temperature graph stayed completely flat before any solid reactant was added.

In the app, students agree or disagree from their own data.

Conclusion

The reaction between citric acid and baking soda is endothermic because it absorbs heat from the liquid, making the temperature drop.

Conclusion

The reaction between hydrochloric acid and magnesium is exothermic because it releases thermal energy, warming up the liquid.

Conclusion

Temperature changes, gas bubbles, and disappearing solids are clear evidence that a chemical reaction produced entirely new substances.

Think back

Think like a scientist

  • Why was it important to wait 10 to 20 seconds before adding the solid reactant?
  • How does the polystyrene foam cup help you get a more accurate temperature reading?
  • If you mixed twice as much magnesium into the acid, what would you predict for the temperature change?

Question 1

What is the scientific term for a chemical reaction that releases thermal energy into its surroundings?

  1. Exothermic
  2. Endothermic
  3. Insulation
  4. Equilibrium

Question 2

In Part I, what happened to the temperature when baking soda was added to citric acid?

  1. It dropped from about 23 °C down toward 2 °C
  2. It rose from about 23 °C up to 35 °C
  3. It stayed completely constant at 23 °C
  4. It dropped below freezing and turned to solid ice

Question 3

A reaction started at 22.0 °C and reached a peak temperature of 36.5 °C. What is the temperature change (delta T)?

  1. 14.5 °C
  2. 58.5 °C
  3. 22.0 °C
  4. 36.5 °C

Question 4

Why did the mixture get icy cold when baking soda was stirred into citric acid?

  1. The reaction absorbed thermal energy from the surrounding liquid
  2. Baking soda released cold rays into the cup
  3. The stirring rod cooled down the liquid by moving quickly
  4. The foam cup sucked heat away from the beaker

Question 5

What would happen to the temperature curve if you forgot to add the magnesium ribbon to the hydrochloric acid?

  1. The graph would stay as a flat line at room temperature
  2. The graph would climb up to 35 °C on its own
  3. The graph would drop down to 2 °C
  4. The graph line would disappear completely

Question 6

Which of these is clear visual evidence that a chemical reaction took place in Part II?

  1. Gas bubbles formed and the solid magnesium ribbon disappeared
  2. The liquid changed from clear to dark purple
  3. The foam cup melted into a puddle
  4. The volume of liquid doubled instantly

Question 7

Why do we place the foam cup inside a heavy glass beaker during the experiment?

  1. To keep the light foam cup steady so it does not tip over
  2. To heat up the reaction from underneath
  3. To absorb all the acid fumes produced
  4. To make the temperature probe record faster

Question 8

A student added baking soda at 0 seconds instead of waiting 10 seconds. What problem does this cause?

  1. There is no flat baseline to accurately find the starting temperature
  2. The temperature probe will stop working
  3. The reaction will change from endothermic to exothermic
  4. The baking soda will not dissolve at all

Question 9

What is the correct order of actions when setting up Part I?

  1. Pour citric acid, clamp probe in cup, wait 45 seconds, tap Collect, add baking soda at 10 seconds
  2. Add baking soda, pour acid, tap Collect, then put the probe in
  3. Tap Collect, add baking soda, wait 45 seconds, then clamp the probe
  4. Clamp the probe, add baking soda, tap Collect, then pour the acid

Question 10

Why does an adult pour the 1.0 M hydrochloric acid instead of students?

  1. Hydrochloric acid is corrosive and can cause severe skin and eye burns
  2. Hydrochloric acid is too heavy for students to lift
  3. Acid evaporates instantly into thin air if students touch it
  4. The temperature probe will only connect when a teacher pours

Question 11

Which everyday product works using the exact same endothermic principle as Part I?

  1. An emergency squeeze cold pack used for sprains
  2. An iron-powder pocket hand warmer
  3. A wax candle burning on a table
  4. An electric hair dryer blowing warm air

Question 12

Campers and soldiers use 'flameless ration heaters' to warm their meals. Based on today's lab, what type of reaction do they rely on?

  1. An exothermic reaction that releases heat when water reacts with metal
  2. An endothermic reaction that pulls cold out of the food
  3. A physical change where water freezes onto the pouch
  4. A nuclear reaction that splits atoms inside the meal

Question 13

A student's Part I graph shows the temperature stayed at 22.5 °C the entire time. What is the most likely error?

  1. The baking soda was never added or sat at the bottom unstirred
  2. The student used too much citric acid
  3. The room was too bright for the temperature probe
  4. The foam cup was too cold to begin with

Question 14

Comparing the two graphs, which statement correctly describes the energy flow?

  1. Part I absorbed energy from the surroundings, while Part II released energy into the surroundings
  2. Both reactions absorbed equal amounts of thermal energy
  3. Both reactions released thermal energy into the air
  4. Part I released heat and Part II absorbed heat

Question 15

Why did we rinse the temperature probe thoroughly with distilled water between Part I and Part II?

  1. To prevent leftover citric acid and baking soda from contaminating the hydrochloric acid
  2. To cool the stainless steel probe shaft down to 0 °C
  3. Because water is required to power the probe battery
  4. To remove the blue color from the sensor handle

Question 16

What gas was produced during the exothermic reaction between hydrochloric acid and magnesium?

  1. Hydrogen gas
  2. Carbon dioxide gas
  3. Oxygen gas
  4. Helium gas
Baking soda and household white vinegar bottle with temperature probe

Try These

Kitchen Vinegar Cold Challenge

  • Try replacing 1.5 M citric acid with 30 mL of ordinary household vinegar (acetic acid).
  • Add 10 g of baking soda and record the temperature drop. Is vinegar as cold as citric acid?
Yeast packet and bubbling hydrogen peroxide foam in a beaker

Try These

Yeast and Peroxide Warm-Up

  • Mix 30 mL of 3% hydrogen peroxide with a spoonful of active dry baker's yeast in a foam cup.
  • Watch the thick foam rise and measure the exothermic heat climb. How many degrees does it gain?
Steel wool wrapped around temperature probe tip inside a cup

Try These

Slow Rusting Heat

  • Soak a pad of fine steel wool in vinegar for two minutes to strip its protective coating.
  • Squeeze it dry, wrap it tightly around the tip of the temperature probe, and slide both into a cup.
  • Track the temperature for 15 minutes as iron reacts with oxygen. Rusting is an exothermic reaction!
Three cups with different amounts of baking soda lined up for comparison

Challenge

Design the Ultimate Cold Pack

  • Can you make the temperature drop even further by changing the ratio of baking soda to citric acid?
  • Plan an experiment testing 5 g, 10 g, and 15 g of baking soda while keeping citric acid volume at 30 mL.
  • Find the exact combination that reaches the lowest temperature without wasting powder!

Run this lab with your class

Students follow the same screens in the Stemious app, record live sensor data and take the quiz, and their work is saved to their record.

Get the app for my class

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 7, Science, chapter 5: Changes Around Us: Physical and Chemical
  • Related Class 8, Science, chapter 8: Nature of Matter: Elements, Compounds, and Mixtures
  • Direct Class 10, Science, chapter 1: Chemical Reactions and Equations
ICSE (CISCE)
  • Related Class 7, Chemistry, chapter 2: Physical and Chemical Changes
IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 1.1: Measuring enthalpy changes