A colourful playground merry-go-round spinning with motion blur

Wonder

Why do you feel thrown sideways on a spinning playground ride?

Show the answer

To turn in a circle, an object must constantly change direction. That requires an inward pull. Today you will measure this inward acceleration on a spinning platter.

Top down view of an old vinyl record player spinning smoothly

Introduction

The Secret Pull of the Circle

Have you ever ridden a spinning playground carousel? The faster it spins, the harder you must grip the bars to stay on. If you move toward the centre, the ride feels much easier. In this activity, you will attach a wireless motion sensor to a spinning turntable. You will measure the secret inward push that keeps things moving in a circle.

Driving question: Why do you feel pulled inward when moving around a curve?

What you will learn

Today you will discover

  • I can explain which way acceleration points when an object turns in a circle.
  • I can measure how acceleration increases when the turntable spins faster.
  • I can show that sitting farther from the centre increases the inward acceleration.
  • I can set up and zero a wireless motion sensor on a spinning platter safely.
  • I can name real-world machines and vehicles that use circular motion.

Why it matters: Roller coaster engineers, car designers, and satellite trackers use circular acceleration every single day.

Safety first

Scientist Rules for Today

  • Wear safety goggles while the turntable turns.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Tape the sensor firmly to the platter so it cannot fly off when the platter spins.
  • Keep hands, loose clothes, hair, and ruler away from the platter when it turns.
  • Look for the ADULT NEEDED badge: the adult turns on the turntable and adjusts speeds.
  • Never stop the platter with your bare fingers when it spins. Let it coast to a stop.

What you need

  • Go Direct Acceleration Sensor1
  • turntable with 33 1/3 and 45 rpm settings1 · teacher
  • Tablet running Graphical Analysis1
  • masking tape1 roll
  • meter stick1
  • level1
  • safety goggles1 per student
Student hand sliding the acceleration sensor flat along a table surface

Step 1 of 4

Find which way the sensor reads positive

  1. Rest the sensor flat on your benchtop. Point its Y-axis arrow to the right.
  2. Zero the Y-axis reading in Graphical Analysis so it reads near 0.00 m/s2.
  3. Tap Collect. Slide the sensor sharply 30 cm to your right along the arrow and stop.
Stop and check
  • The benchtop is clear of obstacles.
  • The sensor moves horizontally and does not tilt.

Careful: If you tilt the sensor, you mix the gravity of Earth into your horizontal reading. Slide the sensor flat on the table along a straight line.

Sensor taped securely on the turntable platter pointing at the centre spindle

Step 2 of 4 Teacher does this

Level the turntable and mount the sensor

  1. Place the bubble level on the platter while an adult adjusts the bench feet until level.
  2. Tape the sensor near the platter outer edge. Point its Y-arrow directly at the centre pin.
  3. Measure from the centre pin to the sensor case edge. Add 1.2 cm for the inside chip.
Stop and check
  • The turntable platter is level.
  • The tonearm is taped completely out of the way.
  • Tape holds the sensor firmly on both sides.
  • The tonearm is taped back securely so it cannot touch the platter.

Careful: A loose sensor will fly off when it spins and will cause damage or injury. Press strong tape firmly across both ends of the sensor.

Turntable spinning with Go Direct sensor mounted while tablet records data

Step 3 of 4 Teacher does this

Spin the turntable at two speeds

  1. Tap Collect in Graphical Analysis. Wait 20 seconds while the sensor is still.
  2. Have the adult turn the turntable on at 33 1/3 rpm, then switch to 45 rpm after 20 seconds.
  3. After another 20 seconds, have the adult turn the platter off and let it stop.
Stop and check
  • All persons wear safety goggles.
  • Hands stay at least 20 cm back from the platter when it turns.
  • Tape holds the sensor firmly.

Careful: If you reach near a platter that turns, you can cause bumps or pull cables loose. Students watch hands-off while the adult flips the speed switches.

Student measuring radius with a ruler on the turntable platter

Step 4 of 4

Test different distances from the centre

  1. Peel the tape, move the sensor 3 cm closer to the centre, and re-tape securely.
  2. Measure the new distance to the chip: case distance plus 1.2 cm.
  3. Tap Collect. Let the platter spin for 25 seconds. Record the mean acceleration.
Stop and check
  • The turntable stops completely before you touch the sensor.
  • New tape strips are pressed down tight.
  • Y-arrow still points directly at the centre pin.
  • Turntable speed is kept at 45 rpm and collection duration is shortened to 30 seconds.

Careful: If you change position without fresh tape, the sensor can become loose. Use fresh tape every time you move the sensor inward.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 9, Science, chapter 7: Motion
  • Direct Class 11, Physics, chapter 3: Motion in a Plane
IB Diploma
  • Direct Level DP, Physics, chapter 2: A.2 Forces and momentum

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.