Experiments › Physical Science
Why do two cool liquids get warm?
Neutralization Reactions
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does mixing two cool liquids suddenly make the cup feel warm?
Show the answer
When an acid and a base mix, they cancel each other out to make water and salt while releasing warmth. Scientists call this neutralization, and today you will measure it.

Introduction
The Fiery Clash Inside Plain Water
Pour vinegar on baking soda, and you get fizz. But what happens when you mix pure acids and bases? They cancel each other out in a reaction called neutralization. Along the way, invisible chemical bonds break and reform to create ordinary salt and water. This reaction also releases heat energy that you can measure in real time. Today, you will discover why some acid-base pairs release a big burst of heat while others produce only a gentle warm-up.
Driving question: Why do some acid and alkali mixtures heat up much faster than others?
What you will learn
Your Science Goals
- I can test unknown liquids with litmus paper to find acids and bases.
- I can explain why strong acids and bases conduct electricity better.
- I can use a temperature probe to record the heat released in a reaction.
- I can show that strong acid-base pairs release more heat than weak pairs.
- I can explain how neutralization helps in farming and medicine.
Why it matters: Neutralization saves lives during acid spills, balances agricultural soil for crops, and calms heartburn inside your stomach.
Safety first
Chemical Safety Guidelines
- Wear chemical splash goggles and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Acids and bases can cause painful chemical burns on skin and eyes.
- Never taste or smell any solution. Waft gently if you need to smell a solution.
- Keep sensor electronics and tablets at least 30 cm away from all liquid containers.
- If any chemical touches your skin, rinse immediately with cold tap water for 15 minutes.
What you need
- Go Direct Temperature Probe1
- Go Direct Conductivity Probe1 for teacher demo · teacher
- Tablet running Graphical Analysis1
- Polystyrene foam cup and 250 mL beaker2 cups, 1 beaker
- 50 mL graduated cylinder1
- Ring stand with utility clamp1 set
- Glass stirring rod1
- Red and blue litmus paper strips4 strips each
- 1.0 M Acid and Base test solutions60 mL each of NaOH, HCl, NH4OH, HC2H3O2
- Distilled water wash bottle1

Step 1 of 6 Teacher does this
Observe Teacher Conductivity Demonstration
- Your teacher dips the Go Direct Conductivity Probe into 0.05 M solutions of each chemical.
- Watch the live readings on the screen and record the conductivity value for each liquid.
- Notice which solutions conduct thousands of micro-Siemens and which stay very low.
- The teacher wears goggles and purple nitrile gloves.
- Probe is rinsed with distilled water between test solutions.
- Students stand one step back from the demo bench.
Careful: Chemical solutions can splatter when you move the probe or contaminate other beakers. Move the probe slowly. Rinse it fully into a separate waste beaker.

Step 2 of 6
Assemble the Calorimeter and Clamp the Probe
- Place a clean polystyrene foam cup inside a 250 mL glass beaker on the ring stand base. This prevents tips.
- Attach the utility clamp to the stand and secure the Go Direct Temperature Probe.
- Adjust the clamp so the probe tip hangs 1 cm above the cup bottom.
- The ring stand sits flat and firm on the bench.
- The foam cup sits level inside the glass beaker.
- The clamp screw is tight enough that the probe will not slip.
Careful: Foam cups are lightweight and tip easily when empty. Always keep the foam cup inside the heavy glass beaker for stability.

Step 3 of 6
Measure and Test Sodium Hydroxide (NaOH)
- Carefully measure 50 mL of 1.0 M NaOH solution in your graduated cylinder. Pour the 50 mL into the foam cup.
- Dip the glass rod into the liquid. Touch one drop to red litmus paper. Touch another drop to blue litmus paper.
- Record the colour changes. Rinse the glass rod with distilled water into your waste beaker.
- Wear splash goggles and gloves.
- Check the bottle label reads 1.0 M NaOH.
- Pour at eye level to measure exactly 50 mL.
Careful: Sodium hydroxide is caustic and causes skin irritation and eye damage. Pour slowly over a tray. If any spills on skin, wash under cold water immediately.

Step 4 of 6
Measure and Test Hydrochloric Acid (HCl)
- Rinse your 50 mL graduated cylinder fully with distilled water. Measure out exactly 50 mL of 1.0 M HCl solution.
- Use your clean glass rod. Transfer a drop of HCl to red litmus paper. Transfer a drop to blue litmus paper.
- Record the results. Set the cylinder next to the ring stand so that you are ready to mix.
- The cylinder was rinsed clean of any leftover base.
- Goggles and gloves stay firmly on.
- The cylinder of acid rests on a flat, stable surface.
Careful: Hydrochloric acid is corrosive and emits fumes that irritate if you splash it. Do not breathe over open containers. Keep the cylinder stable.

Step 5 of 6
Neutralize NaOH with HCl (Trial 1)
- Tap Collect to start the record of baseline temperature.
- After 5 seconds, smoothly pour the 50 mL of HCl into the cup.
- Stir the mixture gently and continuously with the glass rod until collection stops automatically after 3 minutes.
- Everyone has goggles on.
- The probe tip is in the solution and does not touch the cup wall.
- You are ready to stir immediately after you pour.
- Check that the probe sat in the NaOH cup for at least 30 seconds.
Careful: If you pour too fast, hot acid-base liquid can splash onto hands or sleeves. Pour smoothly in one continuous stream so liquid does not splash. Then stir gently.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 7, Science, chapter 2: Exploring Substances: Acidic, Basic, and Neutral
- Direct Class 10, Science, chapter 2: Acids, Bases and Salts
- Direct Class 7, Chemistry, chapter 7: Chemical Reaction and Chemical Equation
- Direct Class 10, Chemistry, chapter 3: Acids Bases and Salts
- Direct Class 10, Chemistry, chapter 8: Hydrogen Chloride
Versions and what each needs
- Why do two cool liquids get warm?
Physical Science, 60 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.