Experiments › Chemistry
Why do two pale liquids turn ruby red?
Keq
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a red mixture stop changing colour before all the ingredients are used?
Show the answer
Some changes run in both directions at once until both sides match in speed. Scientists call it chemical equilibrium, and today you will find out how it works.

Introduction
The Chemical Tug-of-War
When you bake a cake, you cannot un-bake it. But some chemical reactions are two-way streets. Iron ions and thiocyanate ions combine to form a deep red compound. At the exact same time, the red compound breaks apart back into starting ingredients. When both processes run at the exact same speed, the colour stops changing! Scientists call this balance chemical equilibrium. Today, you will discover how this reaction settles into its steady point.
Driving question: Why does a chemical reaction settle into a steady colour instead of using up all its parts?
What you will learn
Today you will find out
- I can explain what chemical balance or equilibrium means.
- I can identify which colour of light the red product absorbs.
- I can use standard samples to measure an unknown balance mixture.
- I can calibrate a colorimeter and handle a cuvette without fingerprints.
- I can follow safety rules when handling laboratory chemicals.
Why it matters: Reversible reactions control how oxygen binds to your blood, how batteries hold charge, and how medicines work inside your body.
Safety first
Laboratory Safety Rules
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Iron(III) nitrate and nitric acid cause skin and eye irritation. Report any splashes immediately.
- Do not sniff, touch, or taste any chemical solution.
- Keep all liquid containers at least 30 cm away from the tablet and colorimeter.
- Handle glass beakers and cylinders with care. If glassware chips or cracks, alert your teacher.
What you need
- Go Direct Colorimeter1
- Plastic cuvette (4 clear sides)1 with lid
- 10 mL graduated cylinders4
- 50 mL graduated cylinder1
- 100 mL beakers7
- Plastic Beral pipets4
- 0.200 M iron (III), Fe3+, solution in 1.0 M HNO325 mL (in teacher bottle) · teacher
- 0.0020 M iron (III), Fe3+, solution in 1.0 M HNO320 mL (in teacher bottle) · teacher
- 0.0020 M thiocyanate, SCN–, solution30 mL
- Distilled water wash bottle250 mL
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 set per student

Step 1 of 7 Teacher does this
Label your beakers and get chemicals
- Label four small beakers 1, 2, 3, and 4.
- Your teacher will pour stock solutions into labelled supply cups at your station.
- Keep each liquid with its own cylinder and pipet to prevent accidental mixture.
- Everyone has goggles and gloves on.
- Beakers 1 to 4 are clean and labelled.
- The teacher dispenses the solutions that contain acid.
Careful: Nitric acid solution can irritate skin or eyes upon accidental contact. Only the teacher pours concentrated stock liquids. Students wear gloves and keep distance.

Step 2 of 7
Prepare the four standard solutions
- Measure liquids carefully with graduated cylinders. Follow the table.
- Beaker 1 gets 5.0 mL Fe3+ (0.200 M), 4.0 mL SCN-, and 41.0 mL distilled water.
- Beakers 2, 3, and 4 get 3.0 mL, 2.0 mL, and 1.0 mL SCN- with matching water amounts.
- Swirl each beaker gently. Notice how the red shade becomes lighter from Beaker 1 to Beaker 4.
- Read cylinder markings at eye level at the bottom of the meniscus.
- Do not cross-contaminate cylinders or pipets.
Careful: Incorrect volumes change the colour strength and skew results. Check the volume chart before you pour each liquid into the beaker.

Step 3 of 7
Prepare the blank and calibrate the Colorimeter
- Fill a clean cuvette 3/4 full with the blank solution: 0.200 M Fe(NO3)3.
- Handle the cuvette only by the ribbed top edges. Wipe clear faces with a lint-free tissue.
- Place the cuvette into the Colorimeter. Close the lid.
- Press the arrow button until the 470 nm (blue) LED lights up.
- Hold down the CAL button until the red light flashes. Release the button. When it stops, calibration is complete!
- Cuvette clear sides are completely dry and free of smudges.
- Colorimeter is connected to Graphical Analysis on your tablet.
Careful: Fingerprints or droplets on cuvette walls block light and ruin the baseline. Wipe outer walls fully with a lint-free tissue before you insert the cuvette.

Step 4 of 7
Measure the four standard solutions
- Empty the blank cuvette. Rinse it twice with 1 mL of solution from Beaker 1. Fill it 3/4 full.
- Wipe the cuvette clean. Place it in the Colorimeter. Close the lid.
- Tap Collect on your tablet. When the absorbance reading steadies, tap Keep.
- Enter 160 for Beaker 1. Tap Keep Point.
- Repeat for Beaker 2 (enter 120), Beaker 3 (enter 80), and Beaker 4 (enter 40). Tap Stop when finished.
- Measure within 2 to 5 minutes after you mix the solutions. Solutions slowly fade in light.
- Rinse the cuvette with each new solution before you fill it.
Careful: If you wait longer than 5 minutes, red particles slowly decompose in room light. Work efficiently and keep beakers away from bright sunlight.

Step 5 of 7
Fit a straight line through your standards
- In Graphical Analysis, tap Graph Tools and select Apply Curve Fit.
- Choose Linear fit. A straight reference line will appear across your four dots.
- Tap Graph Options. Set Left to 0 and Bottom to 0 so the line passes through (0,0).
- Do not delete this line! It is your reference ruler to measure the equilibrium mixtures.
- All four standard data points are plotted on screen.
- The curve fit line is set to Linear.
Careful: If you delete the curve fit by accident, you cannot measure the unknown mixtures later. Leave the curve fit active on your tablet screen.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 6: Equilibrium
- Related Class 12, Chemistry, chapter 5: Coordination Compounds
- Related Level AS & A Level, Chemistry, chapter 8: Equilibria
Versions and what each needs
- Why do two pale liquids turn ruby red? (colorimeter)
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Colorimeter - Why do two pale liquids turn ruby red? (spectrophotometer)
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.