A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 11 steps. To run it with the sensors, record data and take the quiz, students use the app.

A bicycle tyre in frosty winter grass with a pressure gauge showing lower pressure

Wonder

Why do bicycle and car tyres seem flatter on cold winter mornings?

Show the answer

Cold air particles slow down, hitting the tyre walls with less energy. Today you will trap air in a flask, heat and chill it, and measure the exact change in gas pressure.

Two tyres side by side, one in hot summer sun and one on cold winter ice

Introduction

Why Do Tyres Deflate in Winter?

On a frosty morning, you might notice your bicycle tyres feel softer. Did air leak out overnight? Not usually. The air is still trapped inside, but cold air particles move slower. They bump into the tyre walls less often and with less push. In this lab, you trap an air sample in a sealed glass flask. You will submerge it in ice water, room water, warm water, and boiling water. Using digital sensors, you will discover the exact rule connecting gas pressure and temperature.

Driving question: Why do car and bicycle tyres lose pressure on cold winter mornings?

What you will learn

Today you will find out

  • I can explain how temperature changes gas particle collisions and pressure.
  • I can collect steady temperature and gas pressure data using two sensors at the same time.
  • I can observe the pattern of rising pressure as temperature goes up.
  • I can show that gas pressure is directly proportional to Kelvin temperature.
  • I can connect gas pressure changes to car tyres in winter and pressure cookers in kitchens.

Why it matters: Engineers designing aircraft cabins, doctors filling oxygen tanks, and drivers checking tyre safety all depend on the rule connecting temperature and gas pressure.

Safety first

Lab Rules for Hot Baths and Glassware

  • Wear safety goggles throughout the entire lab. Thermal shock can cause glassware to crack.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The hot plate and water that boils can cause severe burns. Only the teacher handles the bath of water that boils.
  • Never twist or yank the rubber stopper while the flask is hot. Hot air under pressure can pop it loose.
  • Keep all sensor electronic bodies and tablets at least 30 cm away from water beakers.
  • Use utility clamps or heat-resistant gloves when you lift glassware out of warm water.

What you need

  • Go Direct Temperature Probe1
  • Go Direct Gas Pressure Sensor1
  • 125 mL Erlenmeyer flask1
  • Two-hole rubber stopper with valve and tubing1 set
  • 1 L beaker4
  • Ring stand with clamp1 stand, 2 clamps
  • Laboratory hot plate1 · teacher
  • Ice cubesAbout 300 mL
  • Protective lab gloves1 pair heat-resistant
  • Tablet running Graphical Analysis1
  • Safety goggles1 per person
An adult hand in a purple glove placing a 1 L beaker with water on a hot plate

Step 1 of 11 Teacher does this

Have an adult start the boiling bath

  1. Put on your safety goggles.
  2. Have an adult pour about 800 mL of hot tap water into a 1 L beaker.
  3. Place the beaker on the hot plate. Turn the heat to high.
Stop and check
  • Everyone has safety goggles on.
  • The hot plate power cord does not hang over the edge.
  • The beaker has no chips or cracks.
  • Leave the hot plate under adult supervision while you prepare the other baths.

Careful: Hot plates can cause serious burns. A dry or cracked beaker can shatter under heat. Only an adult touches the hot plate and hot beaker. Keep hands at a safe distance.

Three 1 L beakers lined up: one with ice water, one with room water, one with warm water

Step 2 of 11

Prepare the three cool water baths

  1. Prepare Bath 1 (ice water). Pour 700 mL cold tap water into a second 1 L beaker. Add ice cubes.
  2. Prepare Bath 2 (room temp): pour 800 mL room-temperature water into a third 1 L beaker.
  3. Prepare Bath 3 (warm water): pour 800 mL warm tap water into a fourth 1 L beaker.
Stop and check
  • Beakers stand steady on the lab bench.
  • The bench surface is wiped dry.
  • Line the three beakers up in order on your lab bench.

Careful: If you spill water near tablets or sensors, you can damage electronics. Pour slowly over a tray or sink. Keep electronics at least 30 cm away.

Student fingers connecting clear tubing to the gas pressure sensor using a Luer-lock twist

Step 3 of 11

Attach tubing to the gas pressure sensor

  1. Take the clear plastic tube connected to the rubber stopper assembly.
  2. Align the white Luer-lock connector at the free end with the Go Direct Gas Pressure Sensor stem.
  3. Gently twist the connector clockwise half a turn until it locks snug.
Stop and check
  • The sensor rests on a dry bench.
  • Do not force the Luer-lock connector; it turns easily.
  • Leave the blue two-way valve on the stopper open for now (handle aligned with the tube stem).

Careful: If you tighten too much, you can crack the plastic connector stem. Twist gently by hand until snug. Do not use tools.

A student twisting the stopper into the flask and turning the valve perpendicular

Step 4 of 11

Trap the air sample inside the flask

  1. Insert the rubber stopper into the flask neck with a firm twist to make an airtight fit.
  2. Turn the blue handle perpendicular across the valve stem to close the two-way valve.
Stop and check
  • The flask has no cracks around the neck.
  • The stopper is twisted in firmly.
  • Check that the 125 mL flask is dry inside.

Careful: A loose stopper or open valve lets air escape. This causes flat pressure readings. Twist firmly. Make sure that the valve handle forms a cross with the stem.

A student finger tapping the green Collect button on the tablet screen

Step 5 of 11

Start data collection in the app

  1. Tap Collect at the top of the Graphical Analysis screen.
Stop and check
  • Both sensors are connected.
  • The app screen shows live meter boxes.
  • Check that both sensors show green battery and connection lights.
  • No data point is saved until you tap Keep in the next steps.

Careful: If you close the app by accident, you lose your run. Leave the tablet propped up where everyone can see it clearly.

6 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 7, Science, chapter 7: Heat Transfer in Nature
  • Related Class 8, Science, chapter 7: Particulate Nature of Matter
  • Direct Class 11, Physics, chapter 3: Thermal Properties of Matter
  • Direct Class 11, Physics, chapter 4: Thermodynamics
ICSE (CISCE)
  • Related Class 7, Physics, chapter 10: Heat Energy and Its General Effects
  • Related Class 7, Physics, chapter 12: Thermal Expansion and Its Applications
  • Direct Class 8, Physics, chapter 1: States of Matter on the Basis of Kinetic Theory of Matter
  • Related Class 8, Physics, chapter 14: Heat Transfer

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.