Experiments › Earth Science
Why does a cold drink sweat?
Dew Point
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Where do the water droplets on a cold glass really come from?
Show the answer
The cold glass is not leaking or sweating. Invisible water gas in the air chills when it touches the glass. Today you will find the exact temperature where that invisible gas turns to liquid: the dew point.

Introduction
The Mystery of the Sweating Glass
On a hot afternoon, pour ice water into a shiny cup. Minutes later, the outside is covered in wet droplets. People say the cup is sweating, but glass and metal do not have sweat glands! The liquid comes entirely from the air touching the cold cup. In this experiment, you will measure how cold that surrounding air gets. Then you will slowly chill water in a shiny can to discover the exact dew point temperature of your room.
Driving question: Why does a cold drink start sweating on a warm day?
What you will learn
Today you will discover
- I can measure and compare room temperature to air beside cold ice water.
- I can spot the exact moment dew forms on a cold metal can.
- I can find the dew point temperature from my temperature graph.
- I can explain how cooling air creates dew and clouds.
Why it matters: Meteorologists track dew point to forecast sticky summer heat, thick morning fog, frost, and towering thunderstorms.
Safety first
Laboratory Safety Rules
- Wear safety goggles and an apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Check the rim of your metal can. If any edge feels sharp, ask your teacher to tape or smooth it.
- Keep all water, ice that melts, and wet spoons at least 30 cm away from tablets and laptops.
- Wipe up any spilled water immediately with paper towels to prevent slippery lab benches.
- Wash your hands with soap and water after you clean up.
What you need
- Go Direct Temperature Probe1
- small metal can1 (clean, shiny, smooth rim)
- ring stand with clamp1
- Tablet running Graphical Analysis1
- room temperature waterabout 300 mL in a beaker
- ice cubes5 to 6 cubes (for Part 1)
- ice chips1 cup finely crushed
- plastic spoon1
- paper towel4 to 5 sheets
- safety goggles1 per student

Step 1 of 8
Clamp the temperature probe
- Attach the utility clamp to the ring stand.
- Gently tighten the clamp around the handle of the Go Direct Temperature Probe.
- Adjust the height so the probe tip hangs straight down, about 1 cm above the table.
- The ring stand base is stable on the tabletop.
- The clamp grips the black handle, not the metal rod.
Careful: If you tighten a metal clamp too much onto the probe handle, you can crack the plastic case. Tighten the thumbscrew with your fingers until snug; never force it.

Step 2 of 8
Connect and set data collection
- Turn on your Go Direct Temperature Probe. Connect with Bluetooth in Graphical Analysis.
- Tap Mode: set Rate to 0.1 samples/s and End Collection to 900 s.
- Tap Done. The live meter on screen now shows the current room temperature.
- Your hands are dry before you touch the tablet.
- The sensor LED flashes green.
Careful: If you keep data collection at default speed (2 samples/s), the graph becomes overcrowded. Make sure the rate is 0.1 samples per second (one reading every 10 seconds).

Step 3 of 8
Record room temperature and prepare ice water
- Read the room temperature from the live meter on your screen.
- Write this room temperature in Table 1.
- Place 5 to 6 ice cubes in the metal can. Fill the can half full with water.
- Keep the can away from the probe for now while the water chills.
- The metal can is placed on a dry paper towel.
- The can is placed at least 20 cm away from the probe for now.
Careful: If you splash cold ice water onto the probe, you change the baseline room temperature reading too early. Fill the can carefully away from the stand. Keep the probe in open air.

Step 4 of 8
Measure air beside the cold can (Part 1)
- Tap Collect to start data collection. Wait 30 seconds.
- Slide the can of ice water next to the probe so the can is 1 mm from the probe tip.
- Do NOT let the probe touch the metal can.
- Watch the outside of the can. When condensation forms, tap Stop.
- Click the last data point. Record the chilled air temperature in Table 1.
- The probe tip does not touch the metal can.
- The probe tip hangs about 1 mm away from the shiny outer wall.
Careful: If the probe touches the cold metal, it measures the metal surface instead of the air around it. Leave a tiny 1 mm gap of open air between the probe tip and the can wall.

Step 5 of 8
Empty and dry the can completely
- Empty the ice and water from the can into the sink.
- Use paper towels to dry the inside and outside of the can completely.
- Check that the outer surface is shiny, clean, and free of all water droplets.
- Fill the dry can half full with fresh room temperature water.
- The outside of the can is completely dry.
- The water added is at room temperature, not from the cold tap.
Careful: If moisture remains on the can, you can mistake old droplets for new condensation. Rub the outside with a dry paper towel until the metal is completely shiny.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 8: A Journey through States of Water
- Direct Class 6, Chemistry, chapter 10: Atmosphere and Constituents of Air
Versions and what each needs
- Why does a cold drink sweat? (temperature)
Earth Science, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe - Why does a cold drink sweat? (surface temperature)
Climate and Meteorology, 50 min, Based on a Vernier lab
Needs: Go Direct Surface Temperature Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.