Experiments › Earth Science
Why does acid rain hurt some lakes more?
Acid Rain Water
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does identical acid rain kill trout in one lake but spare another?
Show the answer
Some lakes carry a secret chemical shield called a buffer. Today you test natural waters and discover how minerals defend against acid rain.

Introduction
Why Does Acid Rain Hurt Some Lakes More?
When factories and cars burn fuels, sulfur gases rise and mix with raindrops to make acid rain. In some areas, entire fish populations vanish when lake water turns acidic. Yet neighboring lakes stay healthy. What protects them? Today, you will make water acidic using your own breath. Then you will add real acid drops to different waters to uncover nature's secret water shield.
Driving question: Why does acid rain poison some lakes while leaving others completely unharmed?
What you will learn
Today you will find out
- I can measure how blowing carbon dioxide into water changes its pH.
- I can explain how gases in the air make rain acidic.
- I can explain why hard water resists pH drops better than soft water.
- I can rinse the pH electrode properly and test liquids safely.
- I can explain why lakes in some regions suffer more harm from acid rain than others.
Why it matters: Environmental scientists monitor lake buffering so they can treat endangered fisheries with limestone before water life dies.
Safety first
Scientist Rules for Today
- Wear safety goggles and protective gloves at all times. Dilute sulfuric acid can burn eyes and irritate skin.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never inhale or suck through the straw. Only blow gentle, steady bubbles into the beaker.
- Look for the ADULT NEEDED badge. An adult dispenses drops of dilute acid; you count and stir.
- Keep all liquids at least 30 cm away from your Chromebook or tablet. Report any spill immediately.
- The pH sensor tip is thin glass. Never strike the bulb against the bottom or sides of the glass beaker.
- Wash your hands with soap and water after you complete the experiment.
What you need
- Go Direct pH Sensor1 per group
- Tablet running Graphical Analysis1 per group
- 100 mL beakers1 per group
- 250 mL beaker1 per group (for waste)
- ring stand with clamp1 per group
- drinking straw1 per group
- Distilled water wash bottle1 per group
- clear solution in a reagent bottle50 mL each of distilled, soft, hard, and buffer water
- dilute H2SO4 in dropper bottle1 dropper bottle (0.05 M) · teacher
- Splash goggles and nitrile gloves1 set per student

Step 1 of 8
Set up your stand and clamp the pH sensor
- Put on your safety goggles and light blue nitrile gloves.
- Clamp the Go Direct pH Sensor into the utility clamp on your ring stand.
- Unscrew the cap. Slide the storage bottle off.
- Rinse the glass bulb tip fully with distilled water into the waste beaker.
- Everyone has safety goggles and gloves on.
- The ring stand sits flat and sturdy on the table.
- The waste beaker is placed under the sensor tip.
Careful: If you drop the pH sensor or bump its glass bulb, the glass breaks. Tighten the clamp gently around the black plastic shaft, not the glass tip.

Step 2 of 8
Blow breath into distilled water
- Pour 50 mL of distilled water into your clean 100 mL beaker.
- Lower the pH sensor so the glass bulb is completely underwater.
- Insert a straw into the water alongside the sensor.
- Tap Collect. Blow steady, gentle bubbles through the straw for 60 seconds.
- The student who blows has safety goggles firmly on.
- Only blow air outward: never suck in or inhale through the straw.
- Blow gently so water does not splash out of the beaker.
Careful: If you blow too hard, water splashes onto the table and electronics. If you inhale, water enters your mouth. Blow steady, small bubbles outward. Take breaths away from the straw.

Step 3 of 8
Record your breath results and switch to drop mode
- In Graphical Analysis, tap Graph Tools and choose View Statistics.
- Note your Maximum pH (around 6.4) and Minimum pH (around 4.8).
- Calculate the difference: ΔpH = Maximum pH minus Minimum pH.
- Tap File, New Experiment. Set Mode to Event Based with Event Name 'Drops'.
- Data collection has stopped after 60 seconds.
- You wrote down the maximum and minimum pH numbers.
Careful: If you switch experiments before you record statistics, you delete your numbers. Write down your maximum, minimum, and change in pH before you start a new file.

Step 4 of 8 Teacher does this
Test acid drops in distilled water
- Rinse the pH bulb into the waste beaker. Fill the 100 mL beaker with fresh 50 mL distilled water.
- Lower the pH sensor into the water and tap Collect.
- When the reading steadies, tap Keep and enter 0 drops.
- The adult adds 1 drop of dilute sulfuric acid. Stir gently with a glass rod.
- When the pH steadies, tap Keep. Type 1. Repeat up to 10 drops. Tap Stop.
- Everyone has safety goggles and gloves on.
- The adult holds the dilute sulfuric acid dropper bottle.
- A glass stir rod is ready.
Careful: Dilute sulfuric acid can splash into eyes or irritate bare skin. Only the adult dispenses acid drops from close above the beaker. Rinse any splashes with plenty of tap water.

Step 5 of 8 Teacher does this
Test acid drops in soft water
- Empty the 100 mL beaker. Rinse the beaker. Rinse the pH sensor fully with distilled water.
- Pour 50 mL of soft water into the beaker and lower the pH sensor into it.
- Tap Collect (the app automatically saves your first graph as Run 1).
- Record 0 drops. Then the adult adds 1 drop of acid at a time up to 10 drops.
- Stir after each drop, wait for the number to settle, and tap Keep with the drop count.
- The electrode is fully rinsed so no leftover acid carries over.
- Soft water sample measured to exactly 50 mL.
Careful: Splashes from the dropper bottle if held too high. Keep the dropper tip 2 cm above the water surface. Squeeze one drop slowly.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 9, Chemistry, chapter 8: Atmospheric Pollution
- Related Level DP, Environmental Systems and Societies, chapter 6: Atmospheric systems and societies
Versions and what each needs
- Why does acid rain hurt some lakes more?
Earth Science, 50 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.