Why does adding acid make electricity vanish?
Conductimetric
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can mixing two liquids that carry electricity create a liquid that stops electricity?
Show the answer
Both liquids carry electric current because they are full of free moving charges. When mixed, the charges lock into solid crystals and pure water. Scientists call this electrical conductivity, and today you will measure it.

Introduction
The Disappearing Electric Current
Imagine two liquids. Both conduct electricity easily because they are full of swimming charged particles called ions. What happens if you pour one into the other? You might expect double the electricity! Instead, as you drip acid into the base, the electric current plummets. At one special moment, electricity drops almost to zero while a cloud of white powder appears. Today you will track this vanishing act with a conductivity probe and find the exact turning point.
Driving question: Why does adding a conductive acid into a conductive base make the electricity disappear?
What you will learn
Today you will discover
- I can explain why some liquids conduct electricity while pure water does not.
- I can describe how conductivity falls to a minimum and then rises again.
- I can find the exact turning point on a conductivity graph.
- I can safely set up the Stir Station, drop counter, and conductivity probe.
- I can filter, dry, and weigh the solid powder created in the reaction.
- I can explain how water treatment plants use conductivity to detect dissolved minerals.
Why it matters: Water treatment plants and environmental scientists use conductivity every day to test water purity and remove dissolved toxins.
Safety first
Lab Rules for Working with Acids and Bases
- Wear chemical splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sulfuric acid and barium hydroxide irritate skin and eyes. Report any splash immediately.
- Look for the ADULT NEEDED badge. Only an adult handles stock acid and heats with the hot plate.
- Keep all liquids strictly away from tablets, computer keyboards, and sensor charging ports.
- Never taste any lab liquid or touch the white chemical precipitate with bare hands.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct Conductivity Probe1
- Go Direct Drop Counter1
- Vernier Stir Station and stir bar1
- plastic 60 mL reagent reservoir1 · teacher
- Tablet running Graphical Analysis1
- 250 mL beaker2
- 0.100 M Sulfuric acid solution60 mL · teacher
- clear solution in a reagent bottle10 mL · teacher
- glass funnel1
- circular filter paper2 sheets
- Digital balance (0.01 g precision)1 per class
- laboratory hot plate1 per class · teacher
- Distilled water wash bottle1 bottle

Step 1 of 10 Teacher does this
Prepare the base in the beaker
- Have an adult measure 10.0 mL of clear barium hydroxide solution into a clean 250 mL beaker.
- Measure 50 mL of distilled water with a graduated cylinder.
- Pour the distilled water into the beaker. Place the magnetic stir bar inside.
- Everyone wears splash goggles and gloves.
- The 250 mL beaker is clean and free of cracks.
- Adult dispenses the barium hydroxide solution.
Careful: Barium hydroxide can splash and cause skin irritation. Pour slowly down the inside wall of the beaker. Never splash.

Step 2 of 10
Mount the drop counter and probe
- Slide the Drop Counter onto the Stir Station support rod.
- Place the 250 mL beaker onto the illuminated Stir Station platform.
- Insert the Go Direct Conductivity Probe through the large slot of the Drop Counter.
- The Stir Station rests flat on a stable bench.
- The probe cord or wireless antenna is dry and clear of liquids.
- The stir dial is currently switched OFF.
- Lower the probe into the liquid so its hole is submerged, but safely above the stir bar as it spins.
Careful: The stir bar can strike and crack the plastic probe tip when it spins. Position the probe near the side wall of the beaker. Keep it 1 cm above the stir bar.

Step 3 of 10 Teacher does this
Set up the acid reservoir
- Clamp the reagent reservoir above the Drop Counter.
- Have an adult pour about 60 mL of 0.100 M sulfuric acid into the reservoir.
- Momentarily open both valves to fill the dropper tip.
- The adult wears chemical splash goggles and gloves.
- Both blue valve handles are horizontal (closed).
- A waste beaker is placed beneath the tip to catch any drips.
- Turn both blue valve handles on the reagent reservoir sideways to the closed position.
- Place a waste beaker below the tip to catch drips.
Careful: Sulfuric acid solution can leak from an open valve onto the benchtop. Make sure that both valves are horizontal before you pour acid. Keep paper towels ready.

Step 4 of 10
Align dropper tip and start stirring
- Position the reservoir tip roughly 1 to 2 cm directly above the Drop Counter slot.
- Switch on the Stir Station to a steady, medium spin at speed 3 or 4.
- The reservoir tip is centered directly over the rectangular drop slot.
- The stir bar spins smoothly and does not rock.
- The liquid in the beaker is calm and does not splash.
- Make sure drops will fall straight through the slot and plunge directly into the beaker.
- Make sure that the liquid does not splash or pull bubbles into the conductivity probe hole.
Careful: The sensor will not count drops that land on the Drop Counter plastic instead of pass through. Look directly from above to make sure that the dropper tip points straight into the open window.

Step 5 of 10 Teacher does this
Run titration and record drops
- Tap Collect on Graphical Analysis to prepare for data collection.
- Have an adult adjust the top valve to set a flow of 1 drop every 2 seconds.
- Open the bottom valve fully to release drops.
- The tablet runs Graphical Analysis and is ready.
- Adult operates the reservoir flow valves.
- Students watch the graph and count drops.
Careful: If you release drops too quickly in a continuous stream, the drop counter cannot count accurately. Fine-tune the top valve until single drops fall steadily at roughly 1 drop every two seconds.
5 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
Versions and what each needs
- Why does adding acid make electricity vanish?
Advanced Chemistry, 75 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Drop Counter