Salt grains scattered onto an ice cube melting a small pool of water

Wonder

Why do ice-cream trucks and snow trucks both spread salt on ice?

Show the answer

Dissolving extra particles inside a liquid gets in the way of freezing. It forces the liquid to get even colder before it can lock into ice. Today you measure this freezing point depression.

Sea waves splashing against icy rocks in freezing weather without turning solid

Introduction

Why Does Adding Stuff Lower Freezing Point?

Pure water freezes at zero degrees Celsius. But seawater stays liquid even when it is below zero! Why? Because salt particles get between water particles and block ice crystals from forming. Today, you will measure how adding a solute lowers the freezing point of an organic substance. You will watch temperature graphs freeze in real time.

Driving question: Why does tossing salt on an icy road make the ice melt?

What you will learn

Today you will find out

  • I can identify the flat freezing temperature on a cooling graph.
  • I can explain how dissolved particles make it harder for liquids to freeze.
  • I can calculate how many degrees the freezing point dropped.
  • I can safely handle clamped test tubes and temperature probes.
  • I can explain why salt melts ice on roads in winter.

Why it matters: Highway crews, ice cream makers, and car radiator designs all rely on freezing point depression.

Safety first

Laboratory Safety Rules

  • Wear chemical splash goggles and lab aprons at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hot water baths reach 90°C. Only your teacher removes hot test tubes from the heat station.
  • Never pull the temperature probe out of solidified acid. You will bend or break it.
  • Lauric acid and benzoic acid cause skin and eye irritation. Do not touch or taste them.
  • Always carry test tubes securely with a utility clamp. Never carry them with bare fingers.
  • Wash your hands fully with soap at the end of lab.

What you need

  • Go Direct Temperature Probe1 per group
  • Vernier Stir Station and stir bar1 per group
  • Tablet running Graphical Analysis1 per group
  • 400 mL beaker1 per group
  • utility clamp1 per group
  • Test tube of pure lauric acid (~8 g)1 per group · teacher
  • Test tube of lauric acid and benzoic acid mixture1 per group · teacher
  • Splash goggles and nitrile gloves1 set per student
  • paper towel1 pack per group
Teacher placing test tubes into an 80 degree Celsius water bath on a hot plate

Step 1 of 7 Teacher does this

Melt the sample tubes in hot water

  1. Have your teacher place test tubes into a 80-90°C hot water bath.
  2. Watch Tube A (pure lauric acid) and Tube B (lauric acid mixed with benzoic acid).
  3. Observe through the glass as both white solids melt into clear liquids.
Stop and check
  • Teacher wears heat-resistant gloves and goggles.
  • Water bath is stable on hot plate at 80-90°C.
  • Students remain behind the safety line.

Careful: Hot water or molten chemical splashes can cause skin burns. Only the teacher touches the hot water bath and heated glassware.

Beaker with water on Stir Station with gentle vortex and utility clamp attached to rod

Step 2 of 7

Prepare the cooling water bath

  1. Pour about 300 mL of room temperature tap water (20-25°C) into your 400 mL beaker.
  2. Place the beaker onto the platform of the Stir Station.
  3. Drop the magnetic stir bar inside. Turn the dial to stir gently.
Stop and check
  • Beaker is stable on the Stir Station platform.
  • Water temperature is between 20°C and 25°C.
  • Table is dry around electric cables.
  • Attach the utility clamp loosely to the support rod.

Careful: If the stir bar spins too fast, water splashes over the table. Turn the stir knob slowly until water swirls gently. Do not splash water.

Teacher handing clamped hot test tube to student stand, probe inserted into liquid

Step 3 of 7 Teacher does this

Receive hot lauric acid tube

  1. Fasten the utility clamp to the Stir Station rod so the tube hangs above the beaker.
  2. Insert the stainless steel probe into the melted liquid.
  3. Wait 30 seconds for the probe to warm up above 50°C.
Stop and check
  • Teacher uses clamp to hand tube to group.
  • Students wear goggles and blue nitrile gloves.
  • Do not touch the hot glass bottom of the test tube.

Careful: Contact with hot glass causes skin burns. If you drop the tube, hot organic acid spills. Tighten clamp screw securely. Hold only the clamp knob, never the tube.

Student gently moving temperature probe up and down in test tube immersed in water bath

Step 4 of 7

Lower into water bath and record

  1. Tap Collect in Graphical Analysis.
  2. Immediately lower the utility clamp so the test tube sits deep inside the water bath.
  3. Hold the top handle of the probe. Gently move the probe up and down.
Stop and check
  • Outside water level is higher than liquid inside tube.
  • The Stir Station gently stirs the beaker water.
  • Data collection has started on tablet.
  • Make sure beaker water is higher than the lauric acid inside the tube.
  • Stop probe movement immediately when solid forms and the probe sticks.

Careful: If you force a stuck probe, you damage the sensor. Incomplete immersion causes an uneven temperature drop. Move probe very gently. Let go of the probe handle as soon as it stiffens.

Tablet screen showing statistics box on flat graph plateau, and probe being wiped with paper towel

Step 5 of 7 Teacher does this

Find pure freezing point and release probe

  1. Highlight the flat plateau section to record the mean temperature: this is t1 (~44.0°C).
  2. Carry the clamped tube to your teacher's hot water bath to melt the probe free.
  3. Wipe melted acid off the probe with a dry paper towel.
Stop and check
  • Do NOT pull probe out of solid acid.
  • Teacher places tube into hot bath.
  • Paper towels ready to wipe probe.
  • Confirm data collection stops after 10 minutes (600 seconds).
  • Tap Graph Options, then View Statistics to display the mean temperature.

Careful: If you pull on a frozen probe, you can strip internal sensor wires. Wait until the solid melts completely before you lift the probe out.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 12, Chemistry, chapter 1: Solutions

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.