Experiments › Physics

Why does distance protect you?

Distance and Radiation

Grades 7-8Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Hospital medical worker standing behind a barrier operating an X-ray scanner

Wonder

Why do X-ray doctors step behind a wall or stand far away?

Show the answer

Invisible rays spread out in every direction like blowing soap bubbles. As you step back, the energy spreads thin very fast. Today you will measure how distance weakens radiation.

Rays spreading outward in a 3D sphere from a central glowing point

Introduction

Why Does Distance Protect You?

When doctors take an X-ray, they do not just stand beside the patient. They take several steps back or walk behind a protective screen. Even a small increase in distance makes a huge difference in radiation exposure. But why? In this experiment, you will use a radiation counter and a small gamma ray source to find out how radiation strength changes with distance.

Driving question: Why does stepping just a little further away make radiation so much safer?

What you will learn

Today you will find out

  • I can measure how many radiation counts hit a sensor at different distances.
  • I can explain why radiation gets weaker so quickly as distance increases.
  • I can find background radiation and subtract it to get true counts.
  • I can show that doubling distance cuts radiation down to one quarter.
  • I can explain how distance protects doctors and workers from radiation.

Why it matters: Understanding distance and radiation keeps hospital staff, airport workers, and space astronauts safe from high-energy rays.

Safety first

Scientist Rules for Radiation Labs

  • Only your teacher handles the Cobalt-60 button source with tweezers. Never touch it with bare hands.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Keep the source inside its lead container until measurements begin.
  • Look for the ADULT NEEDED badge on steps where an adult handles the source.
  • Never bring food, drinks, or water bottles near the lab bench.
  • Stay behind the tape line at the bench when the source is out of its box.
  • Wash your hands with soap after you finish lab work.

What you need

  • Go Direct Radiation Monitor1
  • radiation button source1 (Cobalt-60 1 µCi in lead container) · teacher
  • meter stick1
  • Tablet running Graphical Analysis1
  • metal tweezers1 pair · teacher
  • roll of tape1 roll
Student hands taping meter stick to clean lab bench

Step 1 of 7

Tape the meter stick to the bench

  1. Lay the meter stick flat along the bench away from edges.
  2. Use two strips of tape to secure both ends so it cannot slide.
  3. Make sure that the numbers face up so you can read centimeters easily.
Stop and check
  • Bench is clean and clear of clutter.
  • Meter stick lies straight and flat.

Careful: A loose meter stick shifts during measurement and gives inaccurate distance values. Press tape down firmly at both the 0 cm and 100 cm ends.

Radiation Monitor lined up with the 0 cm mark of the meter stick

Step 2 of 7

Position the Radiation Monitor at zero

  1. Place the Go Direct Radiation Monitor at the 0 cm end of the meter stick.
  2. The round metal screen window must face directly down the length of the meter stick.
  3. Align the front face of the window right above the 0.00 m mark.
  4. Use a piece of tape to hold the monitor body securely in place.
Stop and check
  • Front metal screen faces toward the 100 cm end.
  • Do not push anything through the protective metal screen.

Careful: A poke to the circular window can puncture the delicate thin mica tube inside. Never touch or press the circular wire screen on the sensor.

Radiation monitor blinking red during 300 second background test with tablet counting

Step 3 of 7

Measure natural background radiation

  1. Make sure that all radiation sources stay safely inside their closed lead boxes across the room.
  2. In Graphical Analysis, start a background run set to count for 300 seconds (5 minutes).
  3. Watch the red LED blink occasionally as cosmic rays and natural particles strike the sensor.
  4. When 300 seconds finish, divide the total count by 5 to find average counts per minute.
  5. Write this background rate in your table (usually 8 to 12 cpm).
Stop and check
  • The radioactive source is still safely sealed in its lead container far away.
  • The bench is steady and undisturbed.

Careful: If you leave a source on the table, the background reading becomes falsely high. Make sure that the Cobalt-60 lead box stays closed and at least 3 meters away.

Teacher placing Cobalt-60 button source at 6 cm with tweezers

Step 4 of 7 Teacher does this

Adult places the source at 0.06 m

  1. An adult opens the lead container with tweezers and lifts the Cobalt-60 button source.
  2. The adult places the center of the source disc exactly on the 6 cm (0.06 m) line.
  3. The flat face of the disc faces straight toward the sensor screen.
  4. Do not place the source closer than 6 cm; the sensor window is too large for point math up close.
Stop and check
  • Teacher wears purple gloves and safety glasses.
  • Students keep hands behind the bench edge.
  • Tweezers are used to hold the disc.

Careful: You drop the radioactive button source or touch it with bare hands. Handle only with tweezers. Place gently on the meter stick.

Student tapping tablet while sensor flashes rapidly in front of source at 6 cm

Step 5 of 7

Count radiation at 0.06 m for 60 seconds

  1. A student taps Collect and then Keep on the tablet.
  2. The sensor counts gamma rays for 60 seconds while the red LED blinks rapidly.
  3. Do not touch the bench or lean over the source while the sensor counts.
  4. When 60 seconds finish, type 0.06 for distance in meters and tap OK.
  5. Write the count in your table.
Stop and check
  • Everyone keeps hands clear of the meter stick.
  • The sensor LED flashes rapidly.

Careful: An accidental bump to the table moves the source during the 60-second count. Stand still and watch the screen timer count down.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

ICSE (CISCE)
  • Related Class 10, Physics, chapter 11: Radioactivity
IB Diploma
  • Related Level DP, Physics, chapter 18: E.3 Radioactive decay

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.