Experiments › Chemistry
Why does hand sanitiser feel cold?
Evaporation of Alcohols
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a drop of sanitiser feel colder than plain water on your palm?
Show the answer
When liquids evaporate, escaping particles steal heat from your skin. Today you will race different liquids and discover how molecular stickiness controls cooling.

Introduction
The Chilling Disappearing Act
Rub hand sanitiser on your skin and you immediately feel an icy chill. Yet the bottle was sitting at normal room temperature! Why did it feel cold? As the liquid turns into gas and vanishes into the air, its fastest particles steal thermal energy from whatever they touch. In this experiment, you will watch two electronic temperature sensors track this cooling effect. You will discover why some liquids chill dramatically while others barely cool at all.
Driving question: Why does rubbing alcohol make your skin feel icy cold as it disappears?
What you will learn
Today you will discover
- I can explain why an evaporating liquid cools its surroundings.
- I can measure how much temperature drops when different liquids evaporate.
- I can tell which liquid has stronger particle attractions from its cooling curve.
- I can prepare sensor probes and collect data using Graphical Analysis.
- I can connect evaporative cooling to sweating and cooling machines.
Why it matters: Sweating keeps your body alive in summer, and refrigerators use evaporative cooling to chill food.
Safety first
Lab Rules for Volatile Liquids
- Wear safety goggles, lab coat and gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The liquids used today are flammable and volatile. No flames or hot surfaces anywhere.
- Never inhale vapours directly or taste any chemical. Work in a well-ventilated room.
- Look for the ADULT NEEDED badge. Only your teacher dispenses and pours these liquids.
- Keep capped bottles away from electrical outlets and tablet screens.
- Wash your hands fully with soap at the end of the lab.
What you need
- Go Direct Temperature Probe2
- Tablet running Graphical Analysis1
- circular filter paper6 squares (2.5 cm x 2.5 cm)
- rubber band2 small bands
- roll of tape1 roll of masking tape
- Test tubes and rack6 capped tubes in 1 rack · teacher
- Splash goggles and nitrile gloves1 set per person

Step 1 of 7
Wrap Probe 1 and Probe 2 tips with paper
- Slip a small rubber band onto the metal shaft of Probe 1 and Probe 2.
- Roll a 2.5 cm square of filter paper into a cylinder around each probe tip.
- Slide each rubber band down over the paper so it holds firmly.
- Both temperature probes are clean and dry.
- Filter paper squares are cut to 2.5 cm by 2.5 cm.
- Rubber bands fit snugly and do not tear the paper.
- Make sure the paper is even with the very end of each probe.
Careful: If the paper slips off, the metal tip will not hold enough liquid to measure the temperature drop. Position the rubber band near the middle of the paper roll so the wrap stays tight.

Step 2 of 7 Teacher does this
Place probes in ethanol and 1-propanol
- Stand Probe 1 in the ethanol tube.
- Stand Probe 2 in the 1-propanol tube.
- Room ventilation is active and no open flames exist.
- An adult wears protective gloves and opens the chemical tubes.
- The test tube rack rests on a sturdy level surface.
- Teacher places capped tubes in the rack and un-caps ethanol and 1-propanol under the ventilation area.
- Make sure the paper wraps are completely under the liquid level.
Careful: Alcohols are highly flammable and their vapours irritate eyes and lungs. Do not breathe vapours directly. Keep tubes firmly in the rack so they cannot tip.

Step 3 of 7
Prepare two tape strips on table edge
- Tear two strips of blue tape, each about 10 cm long.
- Stick one end of each tape lightly to the table edge.
- Keep the probes still in the liquids for at least 30 seconds.
- Table edge is clean and dry so tape sticks well.
- Probes have soaked in the liquids for 30 seconds.
Careful: If tape does not stick, the probe may fall off the table and crack. Press tape down firmly onto the dry wooden tabletop.

Step 4 of 7
Collect data and tape probes over edge
- Tap Collect in Graphical Analysis and watch the graph for 15 seconds.
- At 15 seconds, lift both probes out of the tubes together.
- Tape the probe handles flat to the table so tips hang 5 cm past the edge.
- Both partners know their job: one lifts, one tapes.
- Tape strips are ready on the bench edge.
- Probes have been in liquids for at least 30 seconds.
- Do not touch the wet paper tips with your fingers!
Careful: If you touch the paper, body heat warms it and ruins the temperature data. Hold only the plastic handles. Let the tips hang freely in the air.

Step 5 of 7
Find lowest temperatures and calculate Δt
- Watch the live temperature curves on your tablet screen.
- Find the maximum start temperature (t1) and lowest minimum temperature (t2) for each probe.
- Subtract t2 from t1 to calculate the temperature change: Δt = t1 - t2.
- Do not blow on the probes or fan them with paper.
- Keep hands away from the tips while you take measurements.
Careful: If you blow on the probe, you speed up evaporation artificially. Let air circulate naturally. Do not fan the tips or breathe directly on them.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 8: A Journey through States of Water
- Direct Class 9, Science, chapter 1: Matter in Our Surroundings
- Related Class 11, Chemistry, chapter 4: Chemical Bonding and Molecular Structure
- Related Class 11, Chemistry, chapter 6: Equilibrium
- Related Class 12, Chemistry, chapter 2: Alcohols, Phenols and Ethers
- Direct Level AS & A Level, Biology, chapter 2: Biological molecules
- Direct Level AS & A Level, Chemistry, chapter 4: Chemical bonding
- Direct Level DP, Chemistry, chapter Structure 2.2: The covalent model
Versions and what each needs
- Why does hand sanitiser feel cold? (Chemistry)
Chemistry with Vernier, 75 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe - Why does hand sanitiser feel cold? (Chemistry through Inquiry)
Chemistry through Inquiry, 45 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe - Why does hand sanitiser feel cold? (Physical Science)
Physical Science, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.