Experiments › Biology

Why does milk upset some stomachs?

Lactase Action

Grades 7-8Biology4 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glass bottle of fresh white milk and a carton of lactose-free milk on a table

Wonder

Why do millions of people get stomach aches when drinking milk?

Show the answer

Milk contains a tricky two-part sugar called lactose. People need a biological helper called lactase to chop it up. Today you will catch this enzyme working in real time!

Illustration of a double sugar ring being split in two by a pair of molecular scissors

Introduction

The Mystery of Milk Sugar

Milk is the very first food for every mammal baby on Earth. It is packed with energy from a sugar called lactose. But lactose is a double-ring sugar. Your body cannot absorb it whole! Your small intestine makes an enzyme called lactase to chop lactose into two smaller sugars: glucose and galactose. If you do not have enough lactase, bacteria in your gut ferment the sugar, creating painful gas. Today, you will use test strips and living yeast to test how lactase works.

Driving question: Why can babies digest milk easily, while many adults get sick from it?

What you will learn

Today you will discover

  • I can explain how the enzyme lactase cuts milk sugar into simple sugar.
  • I can test for glucose using color-changing test strips.
  • I can use CO2 gas data to show which sugars yeast can feed on.
  • I can set up the CO2 gas sensor and measure gas production over time.
  • I can explain how lactase drops make milk safe for lactose-intolerant people.

Why it matters: More than two thirds of adults on Earth cannot digest milk easily. Knowing how enzymes work helps doctors treat digestion and helps food companies make lactose-free treats.

Safety first

Lab Rules for Today

  • Wear safety goggles and protective gloves throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste or drink any sugar solution or yeast liquid. Lab solutions are not food.
  • The water bath is warm (37 °C, body temperature). Make sure that it is not too hot.
  • Glucose test strips contain chemicals that can stain surfaces. Discard used strips onto paper towels.
  • Keep all liquids away from laptops and sensor electronics.
  • Wash your hands fully with soap and warm water when finished.

What you need

  • Go Direct CO2 Gas Sensor1 per group
  • Sampling Chamber (250 mL / 2 L)1 per group
  • Tablet running Graphical Analysis1 per group
  • Test tubes and rack3 test tubes and 1 rack
  • 10 mL graduated cylinders1 per group
  • 600 mL beaker1 for water bath
  • glucose urinalysis test strips10 strips per group
  • Plastic Beral pipets3 per group
  • clear solution in a reagent bottleLactose, Glucose, Galactose (5% each)
  • yellow or orange liquid in a reagent bottleLactase enzyme solution with dropper
  • cloudy biological liquid10 mL warm active yeast suspension
  • protective lab gloves1 pair per student
Two test tubes labelled 1 and 2 in a test tube rack

Step 1 of 9

Label your test tubes

  1. Take two clean glass test tubes.
  2. Stick a label on the first tube and write 'Tube 1: Lactose + Lactase'.
  3. Stick a label on the second tube and write 'Tube 2: Lactose Only'.
  4. Place both tubes securely into your test tube rack.
Stop and check
  • Check tubes for cracks or chips.
  • Place tubes in the rack so they do not roll.
  • Goggles and gloves are on.

Careful: Glass tubes that roll off the table can shatter and cut skin. Always keep test tubes upright in the rack. Never lay them on the desk.

Pouring 2.5 mL of clear lactose liquid from a graduated cylinder into a test tube

Step 2 of 9

Add milk sugar (lactose) to both tubes

  1. Use your 10 mL graduated cylinder to measure 2.5 mL of 5% lactose solution.
  2. Carefully pour the 2.5 mL into Tube 1.
  3. Measure another 2.5 mL of lactose solution. Pour it into Tube 2.
  4. Do NOT add any enzyme yet!
Stop and check
  • Read the cylinder at eye level (bottom of curve).
  • Wipe any drips with a paper towel.

Careful: A fast pour can spill liquid over the outside of the tube. Rest the cylinder lip gently against the test tube mouth while you pour.

600 mL beaker with warm water and a thermometer showing 36 degrees Celsius

Step 3 of 9

Set up your warm water bath

  1. Fill your 600 mL beaker about halfway with warm water from the teacher station.
  2. Place the thermometer in the water.
  3. Adjust with small splashes of cool or warm water until the temperature stays between 35 °C and 37 °C.
  4. This matches the warm temperature inside your small intestine!
Stop and check
  • Water must feel warm, not hot.
  • Thermometer bulb stays submerged.

Careful: If water is hotter than 45 °C, it will kill the enzyme and spoil your test. Keep temperature strictly between 35 °C and 37 °C. Ask an adult if you need warm water.

A student placing one drop of liquid onto a yellow glucose test strip

Step 4 of 9

Test both tubes for starting glucose (Time 0)

  1. Take two glucose test strips.
  2. Use a clean dropper. Withdraw one drop from Tube 1 and touch it to the test pad on strip 1.
  3. Rinse the dropper. Withdraw one drop from Tube 2. Touch it to strip 2.
  4. Wait 30 to 60 seconds. Compare the pads to the color chart. Record the glucose level in your table.
Stop and check
  • Do not touch the coloured test pads with bare fingers.
  • Lay strips flat on a dry paper towel.

Careful: A dirty dropper between tubes can contaminate your sample. Rinse the dropper fully with distilled water between Tube 1 and Tube 2.

Adding two drops of lactase enzyme into Tube 1 then placing tubes into warm water bath

Step 5 of 9

Add lactase enzyme to Tube 1 and incubate

  1. Add exactly 2 drops of lactase enzyme solution into Tube 1 only.
  2. Do NOT add any enzyme to Tube 2.
  3. Gently flick the bottom of Tube 1 with your finger to mix the drops.
  4. Place both tubes into the warm 35 to 37 °C water bath. Start your stopwatch!
Stop and check
  • Add enzyme to Tube 1 ONLY.
  • Make sure the water bath level covers the bottom half of the tubes and does not tip them over.

Careful: If you add enzyme to Tube 2, you remove your control sample. Double-check the tube label before you release drops. Tube 2 must stay enzyme-free.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Chemistry, chapter 5: Biomolecules
ICSE (CISCE)
  • Direct Class 6, Biology, chapter 4: Digestive System
  • Direct Class 9, Biology, chapter 11: Digestive System
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 3: Enzymes
  • Related Level AS & A Level, Biology, chapter 16: Inheritance
IB Diploma
  • Direct Level DP, Biology, chapter C1.1: Enzymes and metabolism

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.