Experiments › Physics
Why does more push mean more flow?
Voltage, Current, and Resistance
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does turning a knob make a lamp shine brighter?
Show the answer
Turning the knob gives a stronger electrical push. Scientists call this push voltage, and today you will measure how it drives electric current.

Introduction
The Push, the Flow, and the Squeeze
Imagine water rushing through a pipe. If a pump pushes twice as hard, you expect twice as much water to pour out. Electricity behaves in a very similar way. Voltage is the electrical push, current is the flow of charge, and resistance is the pipe size holding it back. In this lab, you will measure whether pushing twice as hard really doubles the flow, and what happens when parts get hot.
Driving question: If you push electricity twice as hard through a circuit, does twice as much current flow?
What you will learn
Today you will discover
- I can explain what voltage, current, and resistance mean in a circuit.
- I can connect voltage and current probes properly into a circuit.
- I can find the resistance from the slope of a voltage-current graph.
- I can explain why a hot light bulb filament makes a curved graph instead of a straight line.
- I can identify everyday tools that rely on resistance and Ohm's law.
Why it matters: Every smartphone charger, electric car throttle, and dimmer switch uses Ohm's law to control electrical energy safely.
Safety first
Electricity Safety Rules
- Wear safety goggles throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never turn on the power supply until your teacher checks your circuit wires.
- Do not exceed 5.0 V on the power supply. Higher voltage can overheat resistors.
- Resistors and light bulbs can become hot during operation. Do not touch them immediately after you run current.
- Always turn the voltage knob to 0 V before you switch off the power supply or change wires.
What you need
- Vernier Circuit Board 21
- Go Direct Current Probe1
- Go Direct Voltage Probe1
- benchtop DC power supply1 · teacher
- electrical wire with alligator clips4
- miniature light bulb with base socket1 (7.5 V)
- Tablet running Graphical Analysis1
- safety goggles1 per student

Step 1 of 10
Connect and zero the sensors
- Slide the switch on the Go Direct Current Probe to ±1 A.
- Open Graphical Analysis and pair both Go Direct probes over Bluetooth.
- Touch the two leads of the voltage probe together. Tap Zero on the meter.
- Leave the current probe leads unclipped in the air and tap Zero.
- Both probes are charged and switched on.
- The app shows live readings for both probes.
- Leads are untangled.
Careful: Unzeroed sensors will add an offset to your readings and skew the line away from zero. Zero the voltage when clips touch. Zero the current when clips are separate.

Step 2 of 10
Set up the circuit board switches
- Place the Vernier Circuit Board 2 flat on your lab table.
- Locate Switch 1 (SW1) below the battery compartment.
- Slide Switch 1 to the 'External' position.
- Confirm the power supply is switched OFF and turned to 0 V.
- Power supply switch is OFF.
- Voltage dial is turned fully counterclockwise to 0.
- Circuit board is dry and on a stable surface.
Careful: If you leave the power turned on while you set switches, sudden sparks or blown fuses can occur. Always make sure that power is OFF before you change board configuration switches.

Step 3 of 10
Wire the 10-ohm resistor circuit
- Connect a wire from the red positive (+) power supply terminal to board terminal 1.
- Connect board terminal 1 to terminal 2 with a short wire jumper.
- Resistor R1 (10 Ω) sits between terminal 2 and terminal 3.
- Connect the red current probe lead to terminal 3, and its black lead to terminal 22.
- Connect a wire from terminal 23 to terminal 35. Connect terminal 35 back to the negative (-) power supply.
- Power supply remains turned OFF.
- Wires are clipped securely onto the metal turret posts.
- Red leads point toward the positive side of the power supply.
Careful: Incorrect wire connections create short circuits that can trip the board fuse or overheat wires. Double check terminal numbers against the diagram before you move to the next step.

Step 4 of 10
Attach the voltage probe across the resistor
- Connect the red lead of the Go Direct Voltage Probe to terminal 2.
- Connect the black lead of the Go Direct Voltage Probe to terminal 3.
- The voltage probe is now connected across the 10 Ω resistor in parallel.
- Notice: the current probe is in series (in line), while the voltage probe is in parallel (across).
- Red voltage lead is on terminal 2 (positive side).
- Black voltage lead is on terminal 3 (negative side).
- Alligator clips do not touch adjacent posts.
Careful: If you reverse red and black voltage leads, voltage readings become negative. Keep the red clip towards the positive side of the circuit (terminal 2).

Step 5 of 10 Teacher does this
Adult checks the circuit before powering on
- Do NOT turn on the power supply yet.
- Ask your teacher to examine the wire layout.
- The teacher confirms the loop, checks the switch settings, and approves the power turn-on.
- Once approved, turn the power supply knob to 0 V and switch on the power unit.
- No bare clips touch each other.
- Current probe is in series and voltage probe is in parallel.
- Power supply knob is set to 0.0 V.
Careful: If you turn on power to a short-circuited setup, wires can overheat or damage the power supply. Only turn on power after teacher confirmation. Start strictly at 0.0 V.
5 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 10, Science, chapter 11: Electricity
- Direct Class 12, Physics, chapter 3: Current Electricity
- Direct Class 7, Physics, chapter 17: Electric Circuit and Its Components
- Related Class 9, Physics, chapter 9: Electricity and Magnetism 1
- Direct Class 10, Physics, chapter 7: Electric Circuits Resistance and Ohms Law
- Direct Level AS & A Level, Physics, chapter 9: Electricity
- Direct Level DP, Physics, chapter 8: B.5 Currents and Circuits
Versions and what each needs
- Why does more push mean more flow? (Agricultural Science)
Agricultural Science, 45 min, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Voltage Probe - Why does more push mean more flow? (Physics)
Physics with Vernier, 45 min, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Voltage Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.