Experiments › Physics

Why does one bulb go out?

Series and Parallel Circuits

Grades 7-8Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glowing string of holiday lights with one dark socket making several bulbs stay unlit

Wonder

Why does removing one holiday light make all the other lights turn off?

Show the answer

Old holiday lights share one single loop. If one bulb breaks, the whole loop opens! Modern house lights have separate branches. Today you will measure the electrical flow in both setups.

Split comparison showing a single line of vehicles versus multiple branching road lanes

Introduction

Why Does One Bulb Go Out?

Imagine a highway where cars can only drive in single file. If one car breaks down, every car behind it stops. Now imagine a highway that splits into three lanes. If one lane blocks, cars can still drive down the other two! Electric circuits work the same way. In this experiment, you will use wireless sensors to measure electrical push and flow in single-loop series circuits and branched parallel circuits.

Driving question: Why does one burnt-out holiday bulb sometimes turn off every single light on the string?

What you will learn

Today you will discover

  • I can measure voltage and current at different points in a series circuit.
  • I can show that current is the same throughout a single-loop circuit.
  • I can explain how voltage splits up across parts in a series loop.
  • I can explain how current splits across branches in a parallel circuit.
  • I can explain why household lights are wired in parallel.

Why it matters: Every building, computer and smartphone relies on circuits. Wiring them correctly prevents fires and keeps devices powered.

Safety first

Lab Rules for Electrical Circuits

  • Turn off the board switch (SW1) before you move any wire clips. Never adjust live circuits.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never connect the current probe directly across battery terminals without a resistor. That causes a short circuit.
  • Check components for warmth. If any resistor or battery holder feels hot to touch, switch off SW1 immediately.
  • Keep water, wet hands and drinks away from the circuit board and sensors.
  • Always place alligator clip jaws firmly on the metal turret posts, not on insulated plastic.

What you need

  • Vernier Circuit Board 21
  • Go Direct Current Probe1
  • Go Direct Voltage Probe1
  • dry cell battery4 AA cells · teacher
  • electrical wire with alligator clips6 clip leads
  • Tablet running Graphical Analysis1
Student fingers touching voltage probe alligator clips together to zero the probe

Step 1 of 8

Set up board power and connect sensors

  1. Slide switch SW4 on the left to x2 to select two AA batteries.
  2. Make sure that switch SW1 is in the OFF position (middle position).
  3. Turn on both Go Direct probes. Connect them in Graphical Analysis.
  4. Touch the red and black clips of the voltage probe together. Tap Zero.
Stop and check
  • The board is flat on a clean dry table.
  • Switch SW1 is set to OFF before you make any connections.
  • Batteries are seated correctly with positive terminals aligned.

Careful: If you zero the voltage probe when connected to a live battery, it gives false voltage readings. Touch the two voltage probe alligator clips together before you tap Zero.

Circuit Board 2 with red and black leads forming a series loop through resistors R1 and R3

Step 2 of 8

Wire the series circuit with two resistors

  1. Connect a red clip lead from battery positive post 1 to post 2 on resistor R1 (10 ohm).
  2. Connect a second clip lead from post 3 on R1 to post 6 on resistor R2 (51 ohm, formerly R3).
  3. Connect a third clip lead from post 7 on R2 (formerly R3) back to battery negative post 35.
Stop and check
  • Switch SW1 remains OFF while you attach wires.
  • Clip jaws grip only the metal turret posts, not nearby components.
  • Check that you have created a single unbroken loop with no branches.

Careful: If you clip directly across post 1 and post 35, you short out the batteries and make them warm. Always include both resistors R1 and R3 in the loop before you turn on the switch.

Voltage probe clips connected to battery terminals 35 and 1 on Circuit Board 2

Step 3 of 8

Measure battery voltage in the series circuit

  1. Attach the black clip of the voltage probe to post 35 (battery negative).
  2. Attach the red clip of the voltage probe to post 1 (battery positive).
  3. Tap Collect. Slide SW1 to Battery. Wait 5 seconds.
  4. Slide SW1 back to OFF and highlight the steady graph section to record the mean voltage.
Stop and check
  • Voltage probe clips are firmly attached to posts 35 and 1.
  • SW1 is in the OFF position before you tap Collect.
  • One partner operates the tablet while the other controls the switch.

Careful: If you leave the switch ON between runs, the AA batteries drain quickly. Switch SW1 back to OFF as soon as the 5-second data collection stops.

Voltage probe measuring across resistor R1 terminals on Circuit Board 2

Step 4 of 8

Measure voltage drop across each resistor

  1. Keep black clip at post 2 and red clip at post 3 across R1 (10 ohm).
  2. Tap Collect, slide SW1 to Battery for 5 seconds, then switch OFF. Record V1.
  3. Move black clip to post 6 and red clip to post 7 across R3 (51 ohm).
  4. Tap Collect, slide SW1 to Battery for 5 seconds, then switch OFF. Record V2.
Stop and check
  • Always connect black lead at the start of current and red lead at the exit.
  • Switch SW1 is OFF when you disconnect and move leads.
  • Do not unhook the main loop wires.

Careful: If you disconnect the loop wire by accident, the circuit breaks and gives a 0 V reading. Clip the probe directly to the turret post next to the attached wire clip.

Current probe connected in series between post 1 and resistor R1

Step 5 of 8

Measure current at three spots in the series loop

  1. Break the loop between post 1 and R1. Route the red wire to Current probe RED. Connect the black probe lead to post 2.
  2. Collect 5 seconds with SW1 on Battery. Record current I_before.
  3. Move the probe between R1 and R3 (posts 3 and 6). Collect I_middle.
  4. Move the probe between R3 and post 35 and collect I_after. Remember to switch OFF each time!
Stop and check
  • The current probe MUST be wired in series (part of the loop).
  • Current enters probe red terminal and exits probe black terminal.
  • Switch SW1 is OFF whenever you disconnect wires.

Careful: If you connect current probe clips across a resistor in parallel, you bypass the resistor and trip the board fuse. Always break the loop wire and insert the current probe so all loop current flows through it.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Physics, chapter 3: Current Electricity
Cambridge AS & A Level
  • Related Level AS & A Level, Physics, chapter 10: D.C. circuits
IB Diploma
  • Related Level DP, Physics, chapter 8: B.5 Currents and Circuits

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.