Experiments › Chemistry
Why does one drop change everything?
Titration Curves
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does one extra drop make a liquid flip completely?
Show the answer
When an alkaline liquid slowly cancels out an acid, very little changes at first. Then, just one extra drop causes a sudden, giant jump. Scientists call this the equivalence point or turning point, and today you will track it live.

Introduction
The Acid-Base Turning Point
Imagine filling a seesaw with weights. At first, it stays tilted to one side. Then, you place one single marble, and the seesaw suddenly slams down the other way! Neutralizing an acid works just like that. As you add an alkaline liquid to an acid, the mixture fights to stay acidic. But once the acid is almost gone, just a few extra drops cause the pH to shoot upward. Today, you will discover the turning point where acid and base cancel each other out.
Driving question: Why does a single drop of liquid suddenly flip an entire solution from acid to base?
What you will learn
Today you will find out
- I can find the turning point where pH jumps on a graph.
- I can compare the curve shapes made by strong and weak acids and bases.
- I can tell if a color indicator changes at the right time during neutralization.
- I can safely run a titration setup with a pH sensor and stirrer.
- I can explain how neutralizing acids matters in stomach medicines and water care.
Why it matters: Balancing acids and bases keeps swimming pools safe, stops indigestion, and helps factories treat wastewater before it reaches rivers.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hydrochloric acid and sodium hydroxide can irritate skin and eyes. Never touch your face.
- Look for the ADULT NEEDED badge: the adult fills the buret and handles stock chemicals.
- Never taste or drink anything in the lab.
- Position the fragile glass pH sensor so the stir bar never strikes it.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct pH Sensor1
- Stir Station1
- Electrode Support1
- buret1 (50 mL) · teacher
- buret clamp1
- 250 mL beaker1
- 0.10 M Sodium hydroxide solution50 mL · teacher
- 0.1 M Hydrochloric acid solution10 mL · teacher
- phenolphthalein1 dropper bottle
- Distilled water wash bottle1
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 7 Teacher does this
Prepare the acid beaker
- The adult measures 8 mL of 0.1 M hydrochloric acid (HCl) into the 250 mL beaker.
- Add about 100 mL of distilled water to dilute it safely.
- Add 3 drops of phenolphthalein indicator. Swirl gently: the liquid stays clear.
- Everyone wears goggles and protective gloves.
- The adult pours the acid from the stock bottle.
- Keep the beaker on the flat center of the lab bench.
Careful: Acid splashes can cause skin irritation or eye injury. The adult pours the acid. Never inhale fumes directly. Keep goggles firmly in place.

Step 2 of 7
Set up the Stir Station and sensor
- Place the beaker onto the Stir Station platform.
- Carefully slide the magnetic stir bar down the inner wall into the beaker.
- Lower the Go Direct pH Sensor into the liquid near the side.
- The stir bar is placed gently, not dropped in.
- The sensor bulb is submerged in liquid near the glass wall.
- The stir bar does not strike the sensor when it turns.
- Slide the Go Direct pH Sensor into the Electrode Support.
- Set the speed knob to create a gentle, steady swirl with no splashes.
Careful: The stir bar can strike and shatter the thin glass bulb of the pH sensor. Position the sensor close to the side wall of the beaker. Keep it away from the stir bar in the middle.

Step 3 of 7 Teacher does this
Clamp and fill the 50 mL buret
- The adult clamps the 50 mL buret vertically above the Stir Station.
- Rinse the inside with 5 mL of 0.1 M NaOH and drain into a waste beaker.
- The adult fills the buret with 0.1 M NaOH to near the 0 mL mark.
- The buret stopcock valve is turned crosswise (closed).
- A small waste beaker sits beneath the buret when you fill it.
- The buret clamp holds the glass tube firmly and does not crush it.
- Check that the buret tip points directly into the center swirl of the beaker.
Careful: Sodium hydroxide solution is corrosive. It can irritate eyes and skin if it spills when you pour from above. Only the adult pours liquid into the top of the buret. Use a small funnel. Pour slowly at eye level.

Step 4 of 7
Run Trial 1: drip NaOH into HCl
- Tap Collect to start data collection in Graphical Analysis.
- Carefully turn the buret stopcock so it drips at about 1 drop per second.
- Note the exact second the liquid turns pink, then close the stopcock after 240 seconds.
- The stirrer turns gently and smoothly.
- One student is assigned to watch the clock and liquid color.
- One student controls the buret stopcock.
- Watch the clock and the beaker: note that collection stops automatically after 240 seconds.
Careful: A drip rate that is too fast empties the buret before the graph captures the steep turn in the curve. Aim for a steady pace of about 1 drop every second. If it is slightly faster or slower, keep it steady.

Step 5 of 7
Find the turning point time
- Tap the graph curve right in the middle of the steep vertical jump.
- Read the time in seconds at that point. This is the point where the curve turns.
- Compare this time with the exact second phenolphthalein turned pink.
- Buret stopcock is closed tight.
- The sensor remains safe in the clamp.
Careful: If you select the wrong spot on the graph, you get an inaccurate time reading. Tap right at the midpoint of the nearly vertical vertical section of the curve.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 7, Science, chapter 2: Exploring Substances: Acidic, Basic, and Neutral
- Direct Class 11, Chemistry, chapter 6: Equilibrium
- Related Class 12, Chemistry, chapter 4: Amines
- Direct Class 10, Chemistry, chapter 9: Ammonia and Nitric Acid
- Direct Level AS & A Level, Chemistry, chapter 8: Equilibria
Versions and what each needs
- Why does one drop change everything?
Chemistry with Vernier, 50 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.