Experiments › Chemistry / Biology

Why does peroxide fizz on wounds?

Enzyme Activity

Grades 7-8Chemistry / Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A drop of liquid foaming into tiny bubbles on a surface

Wonder

Why does hydrogen peroxide foam the moment it touches a tiny cut?

Show the answer

Your injured skin cells unleash a speedy enzyme called catalase. It instantly shreds harmful peroxide into safe water and fizzing oxygen gas. Today, you will trap that oxygen and measure just how fast this cellular shield works.

Flask foaming with white bubbles while gas pushes up

Introduction

Why Does Peroxide Fizz on Wounds?

When your body turns food into energy, it accidentally makes hydrogen peroxide. This chemical is toxic to living cells. If it built up, it would destroy cell walls. Luckily, almost every living thing carries an enzyme bodyguard called catalase. Catalase tears hydrogen peroxide apart into safe water and oxygen gas. Today, you will use yeast catalase to break down peroxide inside a closed flask. By measuring how fast oxygen gas builds up, you will find the exact speed of this life-saving reaction.

Driving question: How fast can living cells destroy a harmful chemical before it hurts them?

What you will learn

Today you will find out

  • I can explain what an enzyme does in a living cell.
  • I can describe how making oxygen gas changes the pressure inside a closed flask.
  • I can use the steepness of a graph line to find the reaction speed.
  • I can monitor gas pressure safely so the stopper does not pop off.
  • I can name everyday examples where enzymes break down chemicals.

Why it matters: Enzymes keep you alive by speeding up reactions millions of times. Doctors, brewers, and food scientists all study enzyme speed.

Safety first

Scientist Rules for Today

  • Wear splash goggles and nitrile gloves at all times. Hydrogen peroxide can irritate eyes and skin.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste any lab liquid or smell fumes directly from the flask.
  • Watch the pressure reading! If pressure approaches 130 kPa, loosen the stopper or open the valve immediately.
  • Keep all liquids at least 30 cm away from the tablet and sensor body.
  • Clamp the flask securely before you insert the stopper so the glass does not tip over.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • Stir Station1
  • 125 mL Erlenmeyer flask and clamp1 set
  • Two-hole rubber stopper with valve and tubing1 set
  • 25 mL and 50 mL graduated cylinders1 each (50 mL and 10 mL)
  • magnetic stir bar1
  • clear solution in a reagent bottle15 mL (3% H2O2)
  • cloudy biological liquid5 mL yeast catalase suspension
  • Distilled water wash bottle100 mL
  • Tablet running Graphical Analysis1
  • Splash goggles and nitrile gloves1 per person
Connecting pressure sensor and temperature probe to tablet over Bluetooth

Step 1 of 9

Pair both sensors to your tablet

  1. Turn on the Go Direct Gas Pressure Sensor and Go Direct Temperature Probe.
  2. Open Vernier Graphical Analysis on your tablet. Connect both sensors over Bluetooth.
  3. Check that both live readings appear on the screen: pressure in kPa and temperature in °C.
Stop and check
  • Table is clean and dry.
  • No open liquids near the tablet.
  • Both sensors have green lights that blink.

Careful: Sensors might disconnect if Bluetooth drops out or batteries run low. Keep the tablet close to the sensors. Tap Connect again if needed.

Student pouring peroxide from cylinder into Erlenmeyer flask with stir bar inside

Step 2 of 9

Measure water and peroxide into the flask

  1. Measure 50 mL of distilled water in the 50 mL graduated cylinder. Pour it into the 125 mL flask.
  2. Measure exactly 10 mL of 3% hydrogen peroxide in the 10 mL cylinder.
  3. Carefully add the 10 mL of hydrogen peroxide into the flask, then slide in the white stir bar.
Stop and check
  • Wear goggles and gloves.
  • Check cylinder markings at eye level.
  • Flask sits flat on the bench tray.

Careful: Hydrogen peroxide can splash onto skin or into eyes and cause sharp irritation. Pour slowly at chest height. Never lean over open chemicals. Wipe drips right away.

Erlenmeyer flask clamped securely on the Vernier Stir Station

Step 3 of 9

Clamp the flask to the Stir Station

  1. Place the flask on the centre of the Stir Station platform.
  2. Fasten the utility clamp around the upper neck of the flask and tighten the thumb screw to the rod.
  3. Turn the Stir Station dial to setting 5 to test the stir bar. Turn the stirrer off.
Stop and check
  • Flask is held firmly by the clamp.
  • The flask bottom touches the stir platform flat.
  • Thumb screws are snug, not over-tightened on glass.
  • The bar must spin smoothly and not bounce.

Careful: If you tighten a metal clamp too much, it can crack thin glass. A loose flask can shake off the stirrer. Tighten until the flask does not wiggle, but do not force the screw.

Student inserting temperature probe into flask to measure liquid temperature

Step 4 of 9

Record the starting mixture temperature

  1. Lower the stainless steel tip of the Go Direct Temperature Probe into the liquid.
  2. Wait 15 seconds until the temperature reading stays steady on your tablet.
  3. Record the temperature in your data table. Remove the probe. Wipe it dry with a soft tissue.
Stop and check
  • Stirrer is stopped while the probe is inside.
  • Probe does not hit the magnetic stir bar.
  • A soft tissue is ready for use.

Careful: If the stirrer runs while you use the probe, the metal tip can hit the magnet. Keep the stirrer off while you hold the temperature probe in the flask.

Connecting clear tubing to Go Direct Gas Pressure Sensor port with Luer-lock

Step 5 of 9

Connect the stopper tubing to the sensor

  1. Take the clear plastic tube attached to the rubber stopper assembly.
  2. Align the white plastic Luer-lock connector with the port on the Go Direct Gas Pressure Sensor.
  3. Gently twist the connector one half turn clockwise until it feels snug.
Stop and check
  • The tube has no kinks or cracks.
  • Twist connector gently: half turn is enough.
  • Check blue valve handle is perpendicular (closed).
  • Make sure the blue two-way valve on the stopper is turned crosswise so it stays fully CLOSED.

Careful: Too much force on the plastic Luer connector can snap the plastic tabs. An open valve leaks gas. Use only fingers to turn half a turn. Confirm the valve crossbar points across the tube.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 2.2: How fast? The rate of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.