Experiments › Biology / Life Science

Why does peroxide fizz?

Enzyme Action

Grades 7-8Biology / Life Science8 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A drop of liquid foaming into white bubbles on contact

Wonder

Why does hydrogen peroxide bubble when poured on a scraped knee?

Show the answer

Your blood cells contain catalase, a super-fast enzyme. It instantly tears harmful hydrogen peroxide apart into harmless water and oxygen bubbles. Today you will measure that chemical speed using a gas pressure sensor.

A brown plastic first-aid antiseptic bottle on a bathroom counter with fizzy white foam on a cotton pad

Introduction

Why Do Scrapes Bubble When Cleaned?

When you put hydrogen peroxide on a scrape, white foam fizzes up immediately. That happens because living cells make a special helper called an enzyme, named catalase. Catalase quickly breaks down toxic hydrogen peroxide into harmless water and oxygen gas bubbles. In this experiment, you will measure how fast catalase works as you add more enzyme.

Driving question: Why do scrapes bubble when cleaned?

What you will learn

Goals for today

  • I can explain what catalase does in living cells.
  • I can set up and record gas pressure data safely.
  • I can find the reaction rate from a pressure graph.
  • I can describe how adding more enzyme changes the reaction speed.
  • I can give real-world examples where enzymes break down substances.

Why it matters: Enzymes run nearly every reaction in living things, from digesting lunch to healing cuts and helping plants make food.

Safety first

Lab Rules for Today

  • Always wear splash goggles and nitrile gloves. Hydrogen peroxide can irritate eyes and skin.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never twist the Luer-lock connector too tightly. A half-turn is plenty.
  • Watch the pressure value on the screen. If it reaches 130 kPa, disconnect the tube so the stopper does not pop.
  • Point the stoppered test tube away from yourself and others at all times.
  • Wash your hands with soap and water after the cleanup.

What you need

  • Go Direct Gas Pressure Sensor1
  • 1-hole rubber stopper assembly with tubing1
  • Test tubes and rack3 tubes (18 x 150 mm) in 1 rack
  • 10 mL graduated cylinders1
  • 3% hydrogen peroxide solution20 mL
  • Distilled water wash bottle50 mL
  • Enzyme suspension with pipet5 mL active yeast or catalase
  • 250 mL beaker1 (for waste liquid)
  • Splash goggles and nitrile gloves1 set per student
Student marking numbers 1, 2, and 3 on test tubes in a rack

Step 1 of 6

Label your test tubes

  1. Place three clean test tubes in your rack.
  2. Use a grease pencil or label sticker to number them 1, 2, and 3.
  3. Check that each tube is completely clean and dry inside.
Stop and check
  • Goggles and blue gloves are on.
  • Test tubes sit securely in the rack.

Careful: Tubes that roll on the bench can fall and break. Always keep glass test tubes upright in the rack.

Hand connecting plastic tubing to the gas pressure sensor port

Step 2 of 6

Connect tubing to the sensor

  1. Connect the plastic tube to the valve on the Go Direct Gas Pressure Sensor.
  2. Gently twist the white connector a half-turn clockwise until it stops.
  3. Do not over-tighten, or the plastic connector can crack.
Stop and check
  • The sensor body is dry.
  • The plastic connector is clean with no cracks.

Careful: Excess torque breaks the threads. Insufficient torque causes gas leaks. Turn gently until snug. A half-turn is just right.

Student pouring 3 mL from graduated cylinder into test tube 1

Step 3 of 6

Add water and peroxide to each tube

  1. Use your 10 mL cylinder to measure 3 mL of water. Pour the water into tube 1.
  2. Rinse the cylinder. Measure 3 mL of 3% H2O2. Pour it into tube 1.
  3. Repeat for tube 2 and tube 3 so each holds exactly 6 mL total liquid.
Stop and check
  • Safety goggles cover your eyes.
  • Gloves are dry.
  • Tubes sit stably in the rack.

Careful: Hydrogen peroxide splashes on skin or clothes. Pour at eye level over the rack. Wipe drips immediately with paper towel.

Student dropping 1 drop of enzyme into test tube 1 and pressing stopper in

Step 4 of 6

Test Tube 1: 1 drop of enzyme

  1. Use a clean dropper to add exactly 1 drop of enzyme into tube 1.
  2. Instantly push the rubber stopper firmly into tube 1 and tap Collect.
  3. Gently swirl the tube once to mix.
Stop and check
  • Stopper assembly is in hand.
  • Graphical Analysis is open and connected.
  • Teammates know who drops and who taps Collect.
  • Have your stopper and tablet ready before you add the enzyme.
  • Drop straight into the liquid. Do not touch the glass side.
  • Watch the screen continuously as data collects.

Careful: If the drop hits the side wall, the reaction delays. Slow movement lets gas escape before the stopper is in place. Drop straight into liquid, push stopper in immediately, and press Collect.

Tablet screen highlighting a linear curve fit on the graph

Step 5 of 6

Find the slope for Tube 1

  1. On your tablet, drag across the steepest straight region of the graph.
  2. Tap Graph Options, then Apply Curve Fit, and pick Linear.
  3. Record the slope value (m) in your data table as your reaction rate.
Stop and check
  • Data collection has finished.
  • Tube is pointed safely away from faces.
  • When 180 seconds finish, disconnect the stopper and empty the tube into your waste beaker.

Careful: A sudden pull on the tube can splash leftover peroxide. Twist the stopper gently out of the tube before you pour into the waste beaker.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 8: Cell: The Unit of Life
  • Direct Class 11, Biology, chapter 9: Biomolecules
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 2: Biological molecules
  • Direct Level AS & A Level, Biology, chapter 3: Enzymes
  • Direct Level AS & A Level, Biology, chapter P1: Practical skills for AS Level
IB Diploma
  • Direct Level DP, Biology, chapter C1.1: Enzymes and metabolism

Versions and what each needs

  • Why does peroxide fizz? (gas pressure, Agricultural Science)
    Agricultural Science, 50 min, Based on a Vernier lab
    Needs: Go Direct Gas Pressure Sensor
  • Why does peroxide fizz? (O2, Advanced Biology)
    Advanced Biology, 60 min, Based on a Vernier lab
    Needs: Go Direct O2 Gas Sensor
  • Why does peroxide fizz? (gas pressure, Advanced Biology)
    Advanced Biology, 75 min, Based on a Vernier lab
    Needs: Go Direct Gas Pressure Sensor
  • Why does peroxide fizz? (O2, Agricultural Science)
    Agricultural Science, 80 min, Based on a Vernier lab
    Needs: Go Direct O2 Gas Sensor
  • Why does peroxide fizz? (O2, Biology)
    Biology with Vernier, 80 min, Based on a Vernier lab
    Needs: Go Direct O2 Gas Sensor
  • Why does peroxide fizz? (gas pressure, Biology)
    Biology with Vernier, 50 min, Based on a Vernier lab
    Needs: Go Direct Gas Pressure Sensor
  • Why does peroxide fizz? (O2, Investigating Biology)
    Investigating Biology, 60 min, Based on a Vernier lab
    Needs: Go Direct O2 Gas Sensor
  • Why does peroxide fizz? (gas pressure, Investigating Biology)
    Investigating Biology, 60 min, Based on a Vernier lab
    Needs: Go Direct Gas Pressure Sensor

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.