Experiments › Chemistry
Why does salt stop freezing?
Another Look Freezing
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do snowplows throw salt onto frozen roads instead of just scraping them?
Show the answer
Salt messes with how liquid freezes. Pure liquids freeze at one exact temperature, but mixtures freeze lower and slower. Today you will track both with precision temperature probes.

Introduction
Why Does Salt Stop Freezing?
When pure water freezes into ice, its temperature locks into place at exactly 0°C until the last drop turns solid. But what happens if something else is dissolved in the liquid? In this lab, you will compare pure melted phenyl salicylate with a mixture that contains an added pinch of benzoic acid. Watch their cooling curves side by side to uncover why pure substances and mixtures freeze differently.
Driving question: Why does adding a pinch of powder stop a liquid from freezing like it usually does?
What you will learn
Today you will find out
- I can explain why a pure substance stays at one temperature while freezing.
- I can compare cooling curves for a pure substance and a mixture.
- I can find the freezing point from a cooling curve graph.
- I can record dual temperature data safely without breaking lab glassware.
- I can explain how salt on icy roads works using freezing science.
Why it matters: Engineers design car antifreeze, food scientists make smooth ice cream, and road crews prevent black ice using freezing point science.
Safety first
Laboratory Safety Rules
- Wear chemical splash goggles, protective gloves, and a lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hot chemicals in test tubes can burn skin. An adult handles test tubes from the hot water bath.
- Never pull or yank a temperature probe that is frozen inside solid chemical. It will snap the glass tube.
- Phenyl salicylate and benzoic acid irritate eyes and skin. Do not touch the solids directly.
- Notify your teacher immediately if any glass cracks or liquids spill.
What you need
- Go Direct Temperature Probe2
- Stir Station1
- 1 L beaker1
- utility clamps2
- test tube with phenyl salicylate1 (15 g)
- test tube with phenyl salicylate & benzoic acid1 (15 g + 0.5 g)
- 2 crystals of solid phenyl salicylateSmall dish with crystals
- magnetic stir bar1
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 per student

Step 1 of 6
Prepare the warm water bath
- Fill the 1 L beaker about 4/5 full with water blended to 30-32°C, measured using a thermometer or Temperature Probe.
- Place the beaker on the platform of the Stir Station.
- Drop the magnetic stir bar into the beaker. Start a gentle stir.
- Water temperature measured between 30°C and 32°C.
- Beaker is placed securely in the centre of the Stir Station platform.
- A low stir speed prevents splashes.
Careful: Water that turns too fast can splash over the edges. Turn the speed dial slowly until the water gently swirls and does not make a deep vortex.

Step 2 of 6
Connect both temperature probes
- Turn on both Go Direct Temperature Probes.
- Open Graphical Analysis on your tablet. Connect both probes.
- Label Probe 1 for phenyl salicylate and Probe 2 for the mixture.
- Both probes show green LEDs that flash. This shows that Bluetooth is active.
- Probes are clearly marked so you know which is Probe 1 and Probe 2.
Careful: If you mix up probe channels, you interpret the graph backwards. Tape a small label '1' and '2' on the probe handles to match your app display.

Step 3 of 6 Teacher does this
Have adult bring hot melted test tubes
- The teacher uses utility clamps to retrieve both hot test tubes from the 80°C bath.
- Fasten the utility clamps firmly near the tops of the test tubes.
- Carry them directly to your station. Attach clamps to the Stir Station support rod so test tubes stay suspended above the water bath.
- The adult wears heat-resistant gloves and splash goggles.
- Utility clamps are tightened securely around the upper glass rims.
- Students keep hands clear while hot tubes are positioned.
Careful: Hot chemical test tubes at 80°C can cause severe burns or spill hot organic liquid. Only the adult transports hot test tubes. Never touch the hot glass bottom.

Step 4 of 6
Insert probes and start recording
- Insert Probe 1 into pure phenyl salicylate and Probe 2 into the mixture.
- Keep test tubes suspended just above the water bath for 30 seconds to let probes warm up.
- Make sure that both temperatures read above 50°C. Tap Collect.
- Probes rest inside the liquid chemicals and do not touch the tube bottoms.
- Both probes read above 50°C before they enter the water bath.
Careful: If you start collection when liquids are too cold, you cut off the initial cool curve. Make sure that both probes read above 50°C before you lower them into the water.

Step 5 of 6
Lower tubes into cooling bath
- Loosen the clamp holders slightly and lower both test tubes into the beaker water.
- Make sure that the water outside the tubes is higher than the liquid levels inside.
- Tighten the clamps again so the tubes do not hit the magnetic stir bar as it turns.
- Water level in the beaker is higher than the liquid chemical in the tubes.
- Tubes hang at least 2 cm above the stir bar as it turns.
Careful: If tubes hit the magnetic stir bar as it turns, they can crack and shatter. Fasten clamps securely with clearance above the beaker bottom.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Chemistry, chapter 4: Pure Substance, Mixture and Compound
- Direct Class 7, Chemistry, chapter 4: Pure Substance Mixture and Compound
- Direct Class 8, Chemistry, chapter 3: Elements Compounds and Mixtures
- Direct Level DP, Chemistry, chapter Structure 3.2: Functional groups: Classification of organic compounds
Versions and what each needs
- Why does salt stop freezing?
Chemistry with Vernier, 60 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.