Experiments › Chemistry

Why does some rain turn acidic?

Acid Rain

Grades 7-8Chemistry3 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

An ancient marble carved statue weathered and softened by acid rain under grey rain clouds

Wonder

Why are ancient stone statues slowly melting away outdoors?

Show the answer

Gases from car exhaust and coal smoke rise into the sky and dissolve in clouds. Today you will trap these gases, bubble them into water, and watch your pH sensor catch the acid forming.

City skyline with car traffic and clouds gathering in the sky

Introduction

The Chemistry Falling from the Clouds

Rain falling through clean air is naturally a little acidic because carbon dioxide gas dissolves into it. But in cities and industrial areas, car engines and coal power stations pump out nitrogen dioxide and sulfur dioxide. When these gases mix with cloud droplets, they create much stronger acids. In this experiment, you will capture three different air gases in microscale bulbs, bubble them into water, and track the falling pH live on your screen.

Driving question: Why does rain become acidic enough to damage stone statues and lakes?

What you will learn

Today you will discover

  • I can explain how air gases turn rainwater acidic.
  • I can measure the pH drop caused by three different gases.
  • I can tell which air pollutants cause the sharpest drop in pH.
  • I can safely use a pH sensor and microscale gas pipets.
  • I can explain how acid rain damages real environments and buildings.

Why it matters: Acid rain can kill fish in mountain lakes and erode marble landmarks like the Taj Mahal. Understanding where it comes from helps scientists design cleaner fuels and filters.

Safety first

Scientist Rules for Today

  • Wear chemical splash goggles and protective gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 1.0 M Hydrochloric acid (HCl) is corrosive. Only your teacher dispenses the acid.
  • Work at microscale: tiny amounts keep fumes trapped inside pipet bulbs.
  • Never inhale directly over the pipets or squeeze gas into the open room.
  • The Go Direct pH Sensor has a delicate glass bulb. Never bump it on the bottom.
  • Wash your hands fully with soap at the end of the lab.

What you need

  • Go Direct pH Sensor1
  • Stir Station1
  • utility clamp1
  • 20 × 150 mm test tube1
  • 3 Beral pipets with a 2 cm stem3
  • 3 Beral pipets with a 15 cm stem3
  • 100 mL beaker1
  • solid NaHCO3, NaNO2, and NaHSO31 set in beakers
  • 1 Beral pipet with 1.0 M HCl1 (teacher handles) · teacher
  • wash bottle with distilled water1
  • goggles1 per student
Drawing white chemical powder into a short-stem pipet bulb

Step 1 of 6

Label pipets and load powders

  1. Label the three short-stem pipets NaHCO3, NaNO2, and NaHSO3, and the three long-stem pipets CO2, NO2, and SO2.
  2. Squeeze each short pipet bulb. Dip the stem into its powder. Release the bulb to fill the curved bottom.
  3. Stand all pipets bulb-down inside the 100 mL beaker. Make sure that the stems point straight up.
Stop and check
  • Goggles and gloves are on.
  • Labels are clear and match each powder.
  • The 100 mL beaker stands on a flat table.

Careful: Powder spills on tables or gets mixed between pipets. Dip carefully, do not swap pipets, and wipe up any stray powder with a damp towel.

Teacher adding drops of acid into the generator pipet bulb

Step 2 of 6 Teacher does this

Teacher adds acid to generate gases

  1. Call your teacher with the 1.0 M HCl pipet.
  2. Your teacher inserts the narrow acid tip into each short pipet and adds about 20 drops of HCl.
  3. Swirl each bulb gently, and keep them upright in the beaker as gases form.
Stop and check
  • The teacher wears purple gloves and splash goggles.
  • Students keep hands back while acid is dispensed.
  • Pipets remain upright in the support beaker.

Careful: 1.0 M HCl acid can burn eyes or skin if splashed. Only the adult dispenses HCl. Keep the pipets upright. Point the stems straight up.

Go Direct pH Sensor clamped inside test tube with water

Step 3 of 6

Set up test tube and pH sensor

  1. Clamp the 20 x 150 mm test tube upright to the Stir Station rod.
  2. Pour about 4 mL of fresh tap water into the test tube.
  3. Rinse the pH sensor tip with distilled water from your wash bottle, and submerge the glass bulb.
Stop and check
  • Utility clamp is hand-tight on the Stir Station rod.
  • The pH sensor storage bottle is unscrewed and put in a safe spot.
  • Water level covers the glass bulb of the sensor.
  • Keep the test tube clamp secure so the tube does not tilt.

Careful: If you bump the delicate glass bulb on the glass test tube bottom, it can crack. Lower the sensor gently and clamp it 5 mm above the tube bottom.

Long-stem pipet drawing gas from a short generator pipet

Step 4 of 6

Trap gas into the long pipet

  1. Take the long-stem pipet labelled CO2 and squeeze the bulb completely flat.
  2. Slide the stem into the NaHCO3 generator bulb, and slowly release the bulb to suck up clear gas.
  3. Repeat this collection step for NO2 and SO2 in their correct pipets.
Stop and check
  • The long-stem pipet bulb is flat before it enters the bulb.
  • The tip stays 1 cm above the liquid line at all times.
  • Never squeeze gas out into the classroom air.
  • Keep the pipet tip ABOVE the liquid so you do not suck up acid.

Careful: If you pull liquid into the gas pipet, you will ruin the test. Watch the tip closely. Keep it in the empty air space above the liquid.

Squeezing CO2 gas into water while bubbles rise past the pH sensor

Step 5 of 6

Bubble CO2 and record baseline

  1. Slide the long CO2 pipet stem down to the test tube bottom next to the sensor.
  2. Tap Collect, watch the flat baseline for the first 15 seconds, and at 15 seconds squeeze with both hands.
  3. Bubble all the gas out slowly into the water over 20 seconds, then record initial and final pH values.
Stop and check
  • The pipet tip reaches the very bottom of the test tube.
  • The pH sensor electrode is fully in the water.
  • Both partners are ready to observe the screen.

Careful: If you squeeze too fast, water can splash out of the test tube. Squeeze gently and steadily with two thumbs so bubbles rise smoothly.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 7, Science, chapter 4: The World of Metals and Non-metals
  • Direct Class 8, Science, chapter 4: Combustion and Flame
  • Related Class 10, Science, chapter 3: Metals and Non-metals
ICSE (CISCE)
  • Direct Class 7, Chemistry, chapter 9: General Discussion of Constituents of Air
  • Direct Class 10, Chemistry, chapter 12: Practical Chemistry
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 8: Transport in mammals
  • Direct Level AS & A Level, Chemistry, chapter 13: Nitrogen
  • Direct Level AS & A Level, Chemistry, chapter 15: Hydrocarbons
IB Diploma
  • Direct Level DP, Environmental Systems and Societies, chapter 6: Atmospheric systems and societies
  • Direct Level DP, Biology, chapter A4.2: Conservation of biodiversity

Versions and what each needs

  • Why does some rain turn acidic? (Chemistry)
    Chemistry with Vernier, 50 min, Based on a Vernier lab
    Needs: Go Direct pH Sensor
  • Why does some rain turn acidic? (Biology)
    Biology with Vernier, 50 min, Based on a Vernier lab
    Needs: Go Direct pH Sensor
  • Why does some rain turn acidic? (Physical Science)
    Physical Science, 50 min, Based on a Vernier lab
    Needs: Go Direct pH Sensor

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.