Why does sun angle change the heat?
Insolation Angle
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does the noon sun burn your skin while morning sun feels gentle?
Show the answer
The Sun never changes its power during the day. The tilt of the ground changes how tightly sunlight energy packs together. Today you measure that difference with two temperature sensors.

Introduction
Why Does Sun Angle Change the Heat?
The Sun shines with the same huge power all day long. Yet stepping outside at dawn feels cool, while stepping outside at noon feels scorching. Why does that happen? As the Earth turns, sunlight strikes the ground at different angles. When rays hit the ground steeply, the heat packs into a small spot. In this experiment, a light bulb acts as your simulated Sun. You will test how surfaces tilted at 30° and 60° soak up radiant heat.
Driving question: Why is the midday sun so much hotter than the morning sun?
What you will learn
Today you will find out
- I can explain what insolation means in plain words.
- I can record and graph temperature changes on two tilted surfaces.
- I can calculate temperature change and tell which angle got more radiant energy.
- I can tape temperature probes correctly and measure exact distance from a lamp.
- I can connect sun angle to Earth's seasons and solar panel tilt.
Why it matters: Engineers tilt solar panels to catch maximum sunlight. Architects angle roof overhangs to keep homes cool in summer and warm in winter.
Safety first
Scientist Rules for Today
- Wear safety goggles and lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- A 60-watt incandescent light bulb becomes extremely hot within minutes.
- Make sure only the teacher handles mains electrical cords and positions the lit lamp.
- Never touch the glass bulb with bare skin during or immediately after the test.
- Keep tape, papers, and sensor cables away from direct contact with the hot bulb.
- Allow the lamp to cool for at least five minutes before you pack it away.
What you need
- Go Direct Temperature Probe2
- Tablet running Graphical Analysis1
- cardboard angle devices2 (one 30° and one 60°)
- desk lamp with light bulb1 (with 60-watt incandescent bulb) · teacher
- roll of tape1 roll of masking tape
- ruler1 (30 cm metric ruler)
- safety goggles1 per student

Step 1 of 7
Identify and label your 30° and 60° wedges
- Set the two cardboard angle wedges side by side on your bench.
- Notice the shallow slope of 30° on one wedge and steeper slope of 60° on the second.
- Label the sides of the wedges '30°' and '60°' with a pencil or tape.
- The tabletop is clear and flat.
- Both wedges sit firmly and do not rock.
Careful: If you confuse the two wedges, you record reversed data. Check the angle labels before you tape any sensors.

Step 2 of 7
Tape Probe 1 to the 30° wedge
- Place Probe 1 flat along the sloped face of the 30° cardboard wedge.
- Position the metal probe tip exactly 1 centimetre above the bottom edge.
- Press a piece of tape about 10 centimetres long firmly across the metal probe shaft to hold it.
- The probe tip is 1 cm from the bottom edge.
- The sensor body rests securely on the cardboard ramp.
Careful: Tape over the sensor tip can insulate it and slow temperature readings. Tape across the middle of the metal shaft, never directly over the round tip.

Step 3 of 7
Tape Probe 2 to the 60° wedge
- Place Probe 2 along the sloped face of the 60° cardboard wedge.
- Line up the metal probe tip exactly 1 centimetre above the bottom edge.
- Fasten the metal shaft securely with a strip of tape.
- Probe 2 is mounted on the 60° wedge.
- The tip is exactly 1 cm from the bottom edge.
- The sensor will not slide when the wedge stands upright.
- Make sure both probe tips point toward the bottom edge of their wedges.
Careful: Loose tape allows the probe to slip down during the test and change the distance from the lamp. Press the tape firmly down on both sides of the cardboard wedge.

Step 4 of 7
Pair both probes and configure data collection
- Press the power button on Probe 1 and Probe 2 until both status LEDs blink red.
- In Graphical Analysis, tap Sensor Data Collection. Connect both probes and identify 30° and 60°.
- Tap Mode. Set Rate to 50 samples/minute and End Collection to 10 minutes. Tap Done.
- Bluetooth is turned on on your tablet.
- Both probe LEDs blink.
Careful: If you swap the probe serial numbers, your data labels will be backwards. Tap the Identify button in the app: the selected sensor will flash its LED.

Step 5 of 7 Teacher does this
Position the lamp 20 cm from both wedges
- Ask an adult to place the lamp on the tabletop. Point the lamp directly at the two wedges.
- Use a ruler to measure the distance from the round end of the light bulb.
- Adjust the wedges so the bottom end of BOTH wedges is exactly 20 cm from the bulb.
- The lamp power switch is currently OFF.
- The electrical cord is tucked safely away from paths.
- The lamp rests flat and stable on the table.
- Do not switch the lamp on yet.
Careful: If one wedge is closer to the bulb than the other, distance ruins your angle comparison. Measure carefully: the bulb tip must be exactly 20 cm from both wedge bases.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 7, Science, chapter 12: Earth, Moon, and the Sun
Versions and what each needs
- Why does sun angle change the heat?
Physical Science, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.