Experiments › Chemistry
Why does sweet cola taste tangy?
Acid Content of Soft Drinks
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a sweet cola drink have a sharp, tangy kick?
Show the answer
Sugar hides the sour taste, but cola contains acid for that famous tangy bite. Scientists call this acidity, and today you will measure it.

Introduction
How Acidic Is Your Cola?
When you sip a cold cola, you taste sweetness first. But underneath that sugar is a powerful chemical: phosphoric acid. This acid gives cola its sharp flavour and keeps it fresh on store shelves. How much acid is really inside a can? Today, we will add an alkali liquid drop by drop. A smart pH sensor and drop counter will catch the exact moment the acid is completely cancelled out.
Driving question: How much secret acid is hiding inside your dark fizzy cola?
What you will learn
Today you will find out
- I can record how cola pH changes as alkali drops are added.
- I can spot the steep jump on a pH graph that marks the turning point.
- I can find how much base it takes to cancel out the acid in cola.
- I can safely set up and use a pH sensor and drop counter.
- I can explain why soft drink makers add acid and how it affects teeth.
Why it matters: Dentists study drink acids to protect teeth, while beverage factories measure acid daily to keep every bottle tasting identical.
Safety first
Laboratory Safety Rules
- Wear safety goggles, nitrile gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink the cola in the lab. Never use lab glassware for food or drink.
- Sodium hydroxide (NaOH) is a mild irritant. If it touches skin, wash immediately with plenty of tap water.
- Keep electrical equipment and your tablet at least 30 cm away from liquids.
- Handle the pH probe gently. Its glass bulb is very fragile and can break if struck by the stir bar.
What you need
- Go Direct pH Sensor1
- Go Direct Drop Counter1
- Stir Station1
- plastic 60 mL reagent reservoir1
- 0.10 M Sodium hydroxide solution50 mL (0.050 M diluted) · teacher
- can of carbonated soft drink50 mL (decarbonated)
- 250 mL beaker1
- 100 mL graduated cylinder1
- magnetic stir bar1
- Distilled water wash bottle1
- Tablet running Graphical Analysis1

Step 1 of 6
Prepare the diluted cola sample
- Measure 40 mL of flat cola with the 100 mL graduated cylinder. Pour it into the 250 mL beaker.
- Add 60 mL of distilled water to the beaker to reach a total of 100 mL.
- Place the magnetic stir bar gently inside the beaker.
- You wear safety goggles and blue gloves.
- The cola has no bubbles or foam.
- The beaker sits flat on the table.
Careful: If you drop the stir bar heavily, you can crack the glass beaker. Tilt the beaker slightly and slide the stir bar down the side gently.

Step 2 of 6 Teacher does this
Prepare the alkali reservoir
- Pour about 40 mL of 0.050 M sodium hydroxide solution into the reservoir.
- Clamp the reservoir to the Stir Station rod.
- Open both valves briefly to drain 1 mL into a waste beaker. Fill the tip. Close both valves.
- An adult wears purple gloves and safety goggles.
- Waste beaker is positioned directly below the reservoir tip.
- Both blue valve handles are set horizontally (closed).
- Both valves on the 60 mL reservoir are closed with horizontal handles.
Careful: 0.050 M NaOH can splash or leak from loose stopcocks. It can irritate skin. Only an adult pours the NaOH solution. Keep the waste beaker close under the tip.

Step 3 of 6
Assemble Drop Counter and pH sensor
- Slide the Go Direct Drop Counter onto the Stir Station support rod below the reservoir.
- Slide the Go Direct pH Sensor through the large hole in the Drop Counter.
- Lower the pH sensor into the liquid. Submerge the bulb. Keep it clear of the stir bar.
- The pH sensor storage bottle has been unscrewed and set aside safely.
- The pH probe bulb is rinsed with distilled water.
- The beaker is centred on the white LED circle.
- The cola beaker is placed on the Stir Station platform.
- The reservoir tip is lined up directly above the Drop Counter drop slot.
Careful: The stir bar can strike the glass pH bulb and shatter it. Position the pH probe against the side of the beaker, at least 1 cm above the stir bar.

Step 4 of 6 Teacher does this
Start stirring and adjust drop rate
- Turn the Stir Station knob until the stir bar spins gently.
- Have the teacher turn the top valve so drops fall at about 1 drop every 2 seconds.
- Turn the bottom valve horizontal to stop drops until data collection begins.
- The stir bar spins freely and does not touch the pH probe.
- Top valve is set for slow drops (1 drop per 2 seconds).
- Bottom valve is closed so liquid is paused.
- Liquid mixes smoothly. It does not splash or create deep whirlpools.
Careful: Dripping too fast means the liquid cannot mix in time, giving inaccurate pH jumps. Keep drop speed to roughly 1 drop every 2 seconds.

Step 5 of 6
Start titration and collect live data
- Tap Collect on the Graphical Analysis app.
- Turn the handle vertical to open the bottom valve of the reservoir fully.
- Watch the tablet as each drop plots a new data point as the volume increases.
- The stir station is on and stirs smoothly.
- Red light on the Drop Counter flashes with every drop.
- The tablet shows new points on the graph.
Careful: If you bump the table, you can misalign the drop counter. This causes missed drops. Do not lean on or bump the table while the app collects data.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 2: Acids, Bases and Salts
- Related Level AS & A Level, Chemistry, chapter 6: Enthalpy changes
- Related Level AS & A Level, Chemistry, chapter 8: Equilibria
Versions and what each needs
- Why does sweet cola taste tangy? (pH and drop counter)
Chemistry with Vernier, 50 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor - Why does sweet cola taste tangy? (temperature)
Advanced Chemistry, 45 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.