Wonder
Why does mixing baking soda and vinegar make things feel cold?
Show the answer
When baking soda meets vinegar, foaming bubbles appear and the temperature suddenly drops. The chemical reaction soaks up heat from its surroundings. Today you will track this cooling reaction with a live temperature sensor.

Introduction
The Mystery of the Cold Fizz
When you bake a cake or launch a model volcano, you mix baking soda and vinegar. It fizzes wildly. But if you touch the cup, you will feel something surprising: it turns noticeably cold. Where did the warmth go? Today, you will use a live temperature sensor to measure the exact temperature drop during this classic reaction.
Driving question: Why does mixing baking soda and vinegar make the mixture feel cold?
What you will learn
Today you will find out
- I can identify evidence that a chemical reaction took place.
- I can calculate the temperature change when baking soda reacts with vinegar.
- I can explain why an endothermic reaction feels cold.
- I can set up a live temperature probe and Stir Station correctly.
- I can safely measure and handle vinegar and baking soda in a lab.
Why it matters: Sports cold packs, self-cooling cans, and energy-absorbing chemical processes rely on this exact cooling principle.
Safety first
Lab Safety Rules
- Wear safety goggles and lab gloves at all times during the experiment.
- Treat all chemicals as non-food grade laboratory reagents. Never taste or drink vinegar or baking soda.
- Add baking soda gradually to avoid rapid foaming over the rim of the cup.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Keep electronic sensors, tablets, and cables at least 30 cm away from all liquids.
- Immediately wipe up all accidental spills with paper towels. Wash your hands after the lab.
What you need
- Go Direct Temperature Probe1
- Stir Station1
- Electrode Support1
- magnetic stir bar1
- 400 mL beaker1
- foam cup1
- 50 mL graduated cylinder1
- Digital balance (0.01 g precision)1 per station
- commercial liquids50.0 mL
- white chemical powder2.00 g
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per student

Step 1 of 6
Assemble the insulated reaction cup
- Nest a polystyrene foam cup firmly inside a 400 mL glass beaker.
- Place the nested cup and beaker onto the circular platform of the Stir Station.
- Carefully drop a magnetic stir bar into the bottom of the foam cup.
- Goggles and nitrile gloves are on.
- The beaker sits flat on the center of the Stir Station platform.
- The stir bar rests flat at the bottom of the foam cup.
Careful: The lightweight foam cup could tip over easily if not supported by the heavy glass beaker. Always keep the foam cup nested inside the 400 mL glass beaker.

Step 2 of 6
Measure and add the vinegar
- Pour vinegar into a 50 mL graduated cylinder until the bottom of the curve reaches 50.0 mL.
- Carefully pour the 50.0 mL of vinegar into the polystyrene foam cup.
- Set the empty cylinder aside safely.
- Check the volume reading at eye level.
- Do not splash vinegar on hands or surfaces.
Careful: Vinegar splashes can hurt eyes or irritate sensitive skin. Keep your goggles securely on. Pour smoothly and slowly at table level.

Step 3 of 6
Mount probe and start gentle stirring
- Mount the Go Direct Temperature Probe to the Stir Station vertical rod with the Electrode Support clamp.
- Lower the metal probe tip into the vinegar to submerge it. Make sure that the probe does not touch the stir bar.
- Turn the Stir Station knob to setting 2 to stir gently.
- Electrode Support knob is tightened snugly.
- The probe tip is at least 5 mm above the stir bar as it spins.
Careful: If you lower the probe too deep, the stir bar can strike it and cause vibration. Submerge the probe tip in the liquid just above the stir bar as it spins.

Step 4 of 6
Weigh 2.00 g of baking soda
- Place a square of weighing paper onto the digital balance pan and press Tare (Zero).
- Use a clean spatula to add baking soda powder until the balance reads exactly 2.00 g.
- Carefully crease the paper in half to make a funnel. Carry the paper to your station.
- The balance reads 0.00 g with the paper on the pan.
- Hands and spatula are completely dry.
Careful: Powder that spills on the balance pan causes incorrect mass readings. Add powder in small pinches from the spatula until it reads 2.00 g.

Step 5 of 6
Start data collection and add baking soda
- Tap Collect in Graphical Analysis.
- Wait until 3 to 4 points appear on screen (about 10 seconds). Pour the 2.00 g of baking soda into the cup.
- Watch the foam rise and observe the live temperature line on your graph.
- The Stir Station spins gently and does not splash.
- The live temperature reading on screen is steady before you add powder.
- Wait 45 seconds so the probe reaches the steady start temperature of the vinegar.
Careful: If you add all the powder too fast, foam can spill over the cup. Tip the powder smoothly into the liquid over 2 seconds; keep eyes on the foam level.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 7, Science, chapter 5: Changes Around Us: Physical and Chemical
- Related Class 10, Science, chapter 1: Chemical Reactions and Equations
- Direct Class 8, Chemistry, chapter 2: Physical and Chemical Changes
Versions and what each needs
- Why does the fizz feel cold?
Chemistry through Inquiry, 45 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe