Experiments › Chemistry
Why does this drink feel cold?
Unusually Cool Beverage
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can dissolving a spoonful of sweet powder turn warm water icy cold?
Show the answer
Some sweet crystals swallow heat energy from water as they dissolve. Today you will track this cooling fingerprint to identify a mystery powder.

Introduction
The Chilly Sweetener Mystery
At a community party, someone made fruit punch that felt shockingly cold, even before adding any ice! Four different white sweetener powders were found at the refreshment table: sugar, sorbitol, xylitol, and erythritol. When certain crystals dissolve in water, they swallow heat energy from their surroundings, making the liquid turn cold. In this lab, you will measure the exact cooling effect of each powder to solve the mystery.
Driving question: Why does a drink feel icy cold when certain sweet powders dissolve in it?
What you will learn
Today you will discover
- I can explain why dissolving some powders makes water get cold.
- I can record temperature changes as different sweeteners dissolve.
- I can identify a mystery powder by comparing its temperature drop.
- I can set up a stir station and temperature probe safely.
- I can name everyday products that use cooling dissolving crystals.
Why it matters: Food chemists, athletes, and doctors use cooling crystals in mint candies, energy drinks, and instant ice packs.
Safety first
Laboratory Rules for Sweetener Testing
- Wear safety goggles and lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste, lick, or eat any sweetener powders in the lab, even if they look like table sugar.
- Keep all water bottles and cups away from electronic devices, plugs, and computer tablets.
- Position the temperature probe carefully. Make sure it never touches the magnetic stir bar when it turns.
- Wash your hands fully with soap and water after you complete your tests.
What you need
- Go Direct Temperature Probe1 per group
- Stir Station1 per group
- Electrode Support1 per group
- 400 mL beaker1 per group
- foam cup1 per group
- 50 mL graduated cylinder1 per group
- magnetic stir bar1 per group
- Digital balance (0.01 g precision)1 shared per 2 groups
- white chemical powder5 g each of 4 sweeteners + 10 g mystery sample
- Distilled water wash bottle1 per group

Step 1 of 9
Weigh the empty calorimeter cup
- Make sure the foam cup is clean. Place the empty cup on the digital balance.
- Record its mass to 0.01 g in your data record.
- Do not press tare or zero while the cup is on the pan.
- The balance pan is dry and clean.
- The balance displays 0.00 g before you place the cup.
Careful: Drafts or pressure on the bench can cause balance numbers to drift. Stand back slightly and wait for the balance display to stabilize.

Step 2 of 9
Add water and measure total mass
- Use a 50 mL graduated cylinder to measure 50 mL of room-temperature distilled water.
- Pour the water into the foam cup.
- Place the cup with water back on the balance. Record the new mass.
- Water is at room temperature, not chilled from the tap.
- The outside of the foam cup is completely dry.
Careful: Water drops on the balance pan add extra mass that does not belong in the cup. Wipe the cup bottom with a paper towel before you place it on the balance.

Step 3 of 9
Assemble the Stir Station calorimeter
- Nest the foam cup inside a 400 mL glass beaker for stability.
- Place the beaker onto the centre of the Stir Station platform.
- Gently slide a clean magnetic stir bar down into the cup.
- Stir Station power is plugged in safely away from walkway paths.
- The stir speed knob is at 0 before you place the beaker.
Careful: If you drop the stir bar heavily, you can puncture the soft foam bottom. Tilt the cup slightly and let the stir bar slide gently down the inside wall.

Step 4 of 9
Clamp and position the temperature probe
- Clamp the Electrode Support arm to the Stir Station post.
- Slide the Go Direct Temperature Probe into the support hole.
- Lower the probe. Submerge the stainless steel tip 2 to 3 cm in the water.
- Probe clamp knob is tightened firmly so it does not slip down.
- Probe tip does not touch the bottom or side of the foam cup.
- Keep the probe away from the cup wall and high enough so the bar cannot hit it when it turns.
Careful: If the stir bar strikes the metal probe, it creates noisy data spikes and may jam the motor. Position the probe tip about 1 cm above the stir bar and slightly to one side.

Step 5 of 9
Weigh your first sweetener sample
- Place a clean plastic weigh boat on the balance and press Tare (Zero).
- Use a spatula to measure about 5.00 g of your first sweetener (such as Sorbitol).
- Record the exact mass to the nearest 0.01 g in your Evidence Record.
- The weigh boat shows a zero reading before you add powder.
- The spatula is clean and completely dry.
Careful: Cross-contamination of powder bottles spoils the chemical fingerprints. Wipe the spatula with a clean dry tissue between different sweeteners.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 1: Chemical Reactions and Equations
- Direct Level AS & A Level, Chemistry, chapter 6: Enthalpy changes
Versions and what each needs
- Why does this drink feel cold?
Forensic Chemistry, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.