Experiments › Earth Science and Meteorology

Why does warm air feel different?

Temperature and Humidity

Grades 7-8Earth Science and Meteorology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A person wrapping a towel after swimming on a sunny breezy day

Wonder

Why does stepping out of a pool feel freezing even on a warm day?

Show the answer

Water takes heat with it as it evaporates from your skin. Today you will use that cooling power to measure humidity, and discover how warming air changes how damp it feels.

Morning dew droplets on green grass blades in the sun

Introduction

Why Does Warm Air Feel Different?

On some days, the air feels crisp and fresh. On other days, it feels sticky and heavy. Meteorologists measure this using relative humidity. Relative humidity tells us how full of moisture the air is compared to what it can hold. But how do we measure humidity with simple thermometers? And what happens to humidity when the temperature rises inside a sealed space? Today, you will build a two-probe tool called a psychrometer and discover the surprising link between air heat and dampness.

Driving question: Why does hot summer air feel sticky while cool air feels crisp?

What you will learn

Today you will find out

  • I can build a psychrometer and find relative humidity using a lookup chart.
  • I can explain how evaporating water cools down a wet sensor.
  • I can observe what happens to relative humidity when sealed air is heated and cooled.
  • I can explain why warming sealed air makes relative humidity go down.
  • I can connect relative humidity to sticky summer days and weather forecasts.

Why it matters: Weather forecasters, farmers, air conditioning engineers, and greenhouse growers all track relative humidity every day to predict storms and protect crops.

Safety first

Scientist Rules for Today

  • Wear safety goggles and protective lab gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The 100 W incandescent lamp gets extremely hot during operation. Never touch the metal shade or bulb.
  • Keep water beakers at least 30 cm away from all electronic devices and electrical cords.
  • Look for the ADULT NEEDED badge. Your teacher sets the position of the hot lamp and operates the power switch.
  • Gently wave temperature probes by their handles. Never whip, swing, or strike cords against furniture.
  • Wash your hands with soap and water after you complete the activity.

What you need

  • Go Direct Surface Temperature Sensor2
  • Go Direct Weather System1
  • Tablet running Graphical Analysis1
  • cotton gauze roll1 strip (2 cm x 5 cm)
  • roll of tape1 roll of masking tape
  • 100 mL beakers1 with 50 mL room-temperature water
  • plastic storage tub1 large airtight container with lid
  • desk lamp with light bulb1 with 100 W bulb · teacher
  • ruler1 standard 30 cm ruler
  • protective lab gloves1 set per student
Student hand wrapping cotton gauze around a surface temperature probe tip

Step 1 of 9

Wrap gauze around one temperature probe

  1. Take one Go Direct Surface Temperature Sensor as your wet probe.
  2. Wrap a strip of cotton gauze around the tip of the metal probe shaft.
  3. Secure the top of the gauze with a small piece of tape.
Stop and check
  • You wear safety goggles and blue nitrile gloves.
  • The sensor cord is not tangled or stretched.
  • Only one probe receives the gauze wrap.
  • Leave the metal tip covered only by gauze, not tape.
  • Keep the second probe bare and dry.

Careful: Tape over the sensor tip insulates it from water and air. This prevents evaporation. Tape only the upper edge of the gauze so the flat probe tip stays covered by breathable cloth.

Gauze-wrapped probe dipping into a beaker of room temperature water

Step 2 of 9

Moisten the gauze on the wet probe

  1. Dip only the gauze-wrapped tip into the beaker of room-temperature water.
  2. Let the cotton soak up water until it is fully damp.
  3. Touch the tip gently against the inner beaker rim to remove drops.
Stop and check
  • Water is at or slightly above room temperature.
  • The beaker sits at least 30 cm away from the tablet.
  • Hands and sensor handles remain completely dry.
  • Keep the second probe completely dry on the table.

Careful: Ice-cold water makes the wet probe cold before evaporation starts. This creates false readings. Use room-temperature water so only evaporation cools the probe.

Student waving both temperature probes gently in the classroom air

Step 3 of 9

Wave both probes to measure classroom humidity

  1. Tap Collect to start data collection.
  2. Gently wave both probes back and forth through the air at the same speed.
  3. Stop data collection after 60 to 90 seconds when readings become stable.
Stop and check
  • Stand clear of tablet screens, beakers, and classmates.
  • Hold probes by their handles, not by the thin sensor wires.
  • Wave gently and smoothly. Do not whip cords.
  • Hold the dry probe handle in one hand and the wet probe handle in your other hand.

Careful: Cords that swing wildly can strike desks or unplug sensors. Wave gently with a steady forearm motion. Keep probes at waist height.

Finger tracing across the relative humidity psychrometer lookup table

Step 4 of 9

Find classroom relative humidity on the chart

  1. Record your final dry-probe and wet-probe temperatures in your notebook.
  2. Subtract the wet temperature from the dry temperature to find the difference.
  3. Find your relative humidity in Table 3 with your dry temperature and difference.
Stop and check
  • Both temperatures are written down accurately.
  • You have Table 3 open and ready.
  • Example calculation: 20.0 °C minus 15.0 °C equals a 5.0 °C difference.

Careful: Reading the wrong column gives an inaccurate humidity percentage. Use a ruler or finger to trace across the exact row for your dry temperature.

Student holding both probes in outdoor courtyard testing humidity

Step 5 of 9

Repeat the psychrometer test outside

  1. Wave both probes gently for 60 to 90 seconds until readings stabilize.
  2. Record outdoor dry temperature, wet temperature, difference, and chart humidity.
  3. Disconnect both temperature sensors. Close Graphical Analysis.
Stop and check
  • Stay within sight of your teacher outdoors.
  • Keep equipment away from mud, puddles, and direct heavy winds.
  • Gauze is freshly moistened with outdoor-temperature water.
  • Take your two probes and tablet to your assigned outdoor location.
  • Moisten the gauze again with water that matches outdoor air temperature.

Careful: Sensors that fall on concrete or grass can damage the leads. Carry probes securely by their handles and walk carefully.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 8, Science, chapter 1: Crop Production and Management
  • Related Class 9, Science, chapter 12: Improvement in Food Resources

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.