Experiments › Chemistry

Why does warm soda go flat?

Solubility of Gases versus Temperature

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two glasses of fizzy drink, one chilled with ice and full of bubbles, one warm and flat

Wonder

Why does warm soda lose its fizz so much faster than cold soda?

Show the answer

Cold water traps gas molecules tightly between liquid particles. When soda gets warm, fast-moving water particles kick the gas out into the air. Today, you will measure the escaping carbon dioxide gas at different temperatures.

A cold can of soda opened with a tiny mist of escaping carbon dioxide gas

Introduction

Why Does Warm Soda Go Flat?

Crack open an ice-cold can of soda, and tiny bubbles tickle your tongue. Leave that same can in the hot sun for an hour, and it turns flat and sweet. Where did all the fizz go? Soda gets its bubbles from carbon dioxide gas dissolved in water under high pressure. In this experiment, you will warm soda to different temperatures and measure how much carbon dioxide gas escapes into a sealed chamber.

Driving question: Why does an open can of soda go flat much faster on a hot summer day than in the fridge?

What you will learn

What You Will Discover

  • I can measure the amount of carbon dioxide gas released by soda at different temperatures.
  • I can graph my data and describe what happens to released gas as temperature changes.
  • I can explain why warmer liquids hold less dissolved gas than colder liquids.
  • I can follow safety rules around hot plates and glass beakers.
  • I can connect gas solubility in water to real-world environmental issues.

Why it matters: Understanding how gases dissolve in water helps beverage factories make fizzy drinks. It also explains why warming oceans and rivers hold less dissolved oxygen for fish.

Safety first

Lab Safety Rules

  • Wear safety goggles and lab aprons at all times during this experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hot plates become extremely hot: only the teacher adjusts and touches the hot plate surface.
  • Never taste or drink any soda in the science lab. Lab glassware is not food safe.
  • Keep all electrical cords and sensors away from water baths and hot surfaces.
  • Never insert the tip of the CO2 sensor into the liquid; keep it safely in the air above the sample.

What you need

  • Go Direct CO2 Gas Sensor1
  • Go Direct Temperature Probe1
  • Stir Station1
  • 250 mL Nalgene bottle1
  • laboratory hot plate1 per station · teacher
  • 250 mL beaker and 600 mL beaker1 each
  • 10 mL graduated cylinders1
  • utility clamp and ring stand1 set
  • chilled carbonated soda and ice cubes150 mL soda, 1 cup ice
  • Tablet running Graphical Analysis1
A 250 mL beaker with soda resting inside a 600 mL ice-water bath

Step 1 of 6

Prepare the Ice Bath

  1. Place crushed ice and cold tap water into the 600 mL beaker.
  2. Pour about 150 mL of fresh, chilled soda into the 250 mL beaker.
  3. Place the soda beaker into the ice bath and chill for 10 minutes.
Stop and check
  • Wear your safety goggles.
  • Check beakers for cracks or chips before you add liquid.
  • Keep paper towels handy to wipe water drips.
  • Test that your 250 mL beaker nests comfortably inside the ice bath.

Careful: The nested beaker can tip over if you overfill it with water. This dilutes the soda. Fill the 600 mL beaker only one-third with ice so water does not spill over the rim.

Tablet screen showing Bluetooth connection to Temperature Probe and CO2 Sensor

Step 2 of 6

Power On and Connect Sensors

  1. Turn on the Go Direct Temperature Probe and Go Direct CO2 Gas Sensor.
  2. Start Graphical Analysis on your tablet. Connect both sensors with Bluetooth.
  3. Set up 1 Graph with CO2 Gas (ppm) on the y-axis and Time on the x-axis.
Stop and check
  • Keep tablet and sensor power buttons dry.
  • Make sure the CO2 sensor has finished charging.
  • Allow about 3 minutes for the CO2 sensor to warm up and stabilize.

Careful: If you take readings before the CO2 sensor warms up, the values drift and become inaccurate. Wait for the 3-minute warm-up countdown before you start your first trial.

250 mL Nalgene bottle clamped to ring stand on Vernier Stir Station with stir bar inside

Step 3 of 6

Assemble the Stir Station and Bottle

  1. Place the empty 250 mL Nalgene bottle on the Stir Station platform.
  2. Drop a clean magnetic stir bar into the bottle.
  3. Attach the utility clamp to the ring stand and clamp the bottle neck steady.
Stop and check
  • The Stir Station speed dial is turned to 0 (off).
  • The utility clamp thumbscrew is tightened firmly so the bottle cannot slide.
  • Position the ring stand directly beside the Stir Station on the lab bench.

Careful: An unclamped bottle can wobble and spin off the platform when the stir dial turns on. Clamp the neck of the bottle securely before you turn the speed dial.

Go Direct CO2 sensor in Nalgene bottle while liquid stirs on Stir Station

Step 4 of 6

Trial 1: Measure Cold Soda

  1. Measure the temperature of the chilled soda with the temperature probe. Record the temperature.
  2. Use a 10 mL graduated cylinder to measure 5 mL soda. Pour the soda into the 250 mL Nalgene bottle with the stir bar.
  3. Insert the Go Direct CO2 sensor to seal the neck. Tap Collect. Set Stir Station to speed 7. Record CO2 after 2 minutes.
Stop and check
  • The sensor tip must dangle in the air, not touch the liquid.
  • The graduated cylinder must measure exactly 5 mL.
  • Use the temperature probe to record the cold soda temperature in the ice bath.
  • Use a 10 mL graduated cylinder to measure exactly 5 mL of cold soda.

Careful: Liquid destroys the internal sensor element if you submerge the CO2 sensor. Make sure that the perforated tip stays suspended in the air headspace above the liquid.

Teacher warming beaker of soda on hot plate while student rinses bottle

Step 5 of 6 Teacher does this

Flush Bottle and Adult Warms Soda

  1. Rinse the bottle with cold tap water, shake it out, and wave it to flush trapped CO2.
  2. ADULT STEP: Have the teacher move the 250 mL beaker to the hot plate.
  3. Ask the teacher to warm the soda gently by 5°C to 10°C. Stir the soda with a glass rod.
Stop and check
  • The adult wears heat-resistant gloves and goggles.
  • Hot plate cord is kept away from wet bench areas.
  • Students stand one step back from the hot plate.
  • Place the removed CO2 sensor on a clean towel on the bench.
  • Unclamp the Nalgene bottle and discard the 5 mL soda.

Careful: The hot plate burns skin upon contact. If you overheat the soda, it boils vigorously and loses all liquid. Only the adult operates the hot plate. Warm gently on low heat and do not let it boil.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Chemistry, chapter 1: Solutions
ICSE (CISCE)
  • Related Class 8, Chemistry, chapter 15: Carbon Dioxide Gas and Carbon Monoxide Gas

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.